Quantum SCALAR I500 SP6 User Manual

Page 1
Release Notes
Date
Product and Release No.
Firmware Version
Supported Web Browsers
Remote Web Client)
(
June 2010
Scalar® i500 SP6
586G.GS001. (For instructions on library firmware, see the Scalar i500 User’s Guide.)
Microsoft® Internet Explorer 6.0 and 7.0 and M
ozilla Firefox™ 1.0.6 and later versions

Contents 0

Purpose............................................................................................................................ 1
New Features and Enhancements............................................................................... 2
Errata in Documentation .............................................................................................. 2
General Usage Notes..................................................................................................... 2
Compatibility Matrix..................................................................................................... 3
Resolved Issues .............................................................................................................. 4
Known Issues ................................................................................................................. 5
Firmware Versions ........................................................................................................ 9
Documentation............................................................................................................. 10
Contacting Quantum................................................................................................... 11

Purpose 0

Scalar i500 SP6 (586G.GS001) is a service pack release that fixes an issue with Guardian software. These release notes describe this issue in the section under Change Request Number 290 drive and auxiliary firmware compatibility information. Visit
www.quantum.com for additional information about Scalar i500.
Document 6-01378-16, June 2010 1
82. These notes also provide tape
Resolved Issues
http://
Page 2
Release Notes Document 6-01378-16 June 2010

New Features and Enhancements 0

Scalar i500 SP6 (586G.GS001) firmware includes no new features and enhancements for this service pack release.

Errata in Documentation 0

Control Path Failover — The Scalar i500 User’s Guide is missing the
f
ollowing statement: Drives configured for control path failover must be
connected to a host via an NPIV-enabled switch on the same fabric.

General Usage Notes 0

The following are important items that you may notice that are not covered in the
Known Issues section of this document.
Restoring the Library Configuration — You cannot restore a saved
configuration after removing or replacing a control module or expansion module. After removing and/or replacing the module, save the library configuration for future use.
Downgrading Library Firmware—If a library is running firmware version 420G
• or higher, the following restrictions on downgrading apply:
If your library is Quantum branded, you can downgrade to firmware
version 400G or higher. (There is no lower version of Quantum-branded firmware.)
If your library is ADIC branded and has Fibre-Channel I/O blades installed,
you can downgrade to firmware version 400G or higher. You cannot downgrade to a lower version than 400G.
SAS Host Bus Adapter and Host Bus Adapter Drivers—SAS host bus adapter
• and drivers (combined) must support SAS standard 1.1 or higher.
Library Service Utility—You must run the Library Service Utility prior to
upgrading firmware if you are currently running firmware version 320G.GS004 or 400G.GS006.
Firmware Update Tape Functionality—This feature was removed in version SP4
• in order to simplify the firmware update process and prevent errors. This includes creating and erasing firmware update tapes, and updating drive firmware via a firmware update tape.
Internet Explorer 7 Security Message—Internet Explorer version 7 displays an
• informational message stating that the certificate issued by the library is not from a trusted source. This is normal behavior and does not affect library
2 New Features and Enhancements
Page 3
Release Notes
Document 6-01378-16
June 2010
function. The library issues certificates based on local network data and is not a typical Web site that would be issued a certificate by a trusted source for public access via SSL. Accept the warning and continue.
Kerberos Limitation Issue — When setting up the library to use Kerberos
• remote authentication, an error is generated if you try to use the IPv6 address for the qualified domain name (FQDN).
HP DataProtector 6 WORM Media Support — The only WORM media
supported by HP DataProtector 6 is HP-manufactured WORM media.
KDC (AD Server) field. Instead of using the IPv6 address, use the fully

Compatibility Matrix 0

This section provides information on firmware and software compatibility.
Firmware Compatibility0 The following table provides information about library and tape drive firmware
compatibility with Scalar i500® SP6 (586G.GS of the publication date of these release n versions, check
Note: You mus
Component Firmware Version
Library Firmware 586G.GS001
Drive Types
IBM LTO-2 (Fibre) A4N0
IBM LTO-2 (SCSI) A4N0
IBM LTO-3 (Fibre) 93GE
IBM LTO-3 (SCSI) 93GE
IBM LTO-4 (Fibre) A232*
www.quantum.com.
t run the Library Service Utility prior to upgrading firmware if you are currently running firmware version 320G.GS004 or 400G.GS006.
001). This information is current as
otes. For the most recent firmware
IBM LTO-4 (SCSI) A232*
IBM LTO-4 (SAS) A232*
HP LTO-4 (Fibre) H58Z
HP LTO-4 (SAS) A55Z
Compatibility Matrix 3
Page 4
Release Notes Document 6-01378-16 June 2010
Component Firmware Version
IBM LTO-5 FC A5M0
HP LTO-5 FC I27Z
HP LTO-5 SAS X23Z
* Due to security features, you c
drive with tape drive firmware version 82FB or later to previous code levels without following specific instructions. If you must downgrade, contact Quantum Support for assistance.
Software Compatibility 0 To view a list of which backup software packages have been tested for
interoperability with the Scalar i500, see the Quantum Software Compatibility Guide at
http://www.quantum.com/swcompguide.aspx.
annot downgrade the IBM LTO-4

Resolved Issues 0

This release of Scalar i500® SP6 (586G.GS001) firmware resolved the following issues.
Change Request
Number
Service
Request
Number
Description Solution
29082 Cannot add Scalar i500 version i6.1 to
Guardian. When attempting to add to Guardian, you get a “serial number not found” error.
4 Resolved Issues
Fixed.
Page 5
Release Notes
Document 6-01378-16
June 2010

Known Issues 0

This release of Scalar i500® SP6 (586G.GS001) firmware has the following known issues.
Change Request Number
18328 When Fibre Channel port 2 is selected
19299 If you set the time and the time zone in
19390 1424 The log-in screen allows you to log in
20618 Tapes that were assigned to a partition
Service Request Number
Description Workaround
to be the active port in a host port failover configuration, the active port can switch to the default setting, port 1, following a reboot.
the same action, the actual time reported by the library may be incorrect (it may be an hour off from the actual time).
before the library finishes initializing after a firmware upgrade or powercycle.
and were in the I/E station during a firmware upgrade lost their partition assignment.
Reconfigure the host port failover settings so that the intended port is the active port.
Reset the time again (without resetting the time zone).
This may occur intermittently. If it does, you can log in but you will only be able to view RAS tickets. You will not be able to access any other library functions.
Make sure the I/E station is empty before performing a library firmware upgrade. If this happens, remove the tapes from the I/E station, place them back into the I/E station, and reassign.
20631 881498 Not all I/E station slots are available to
all partitions. Tapes that are in these slots and assigned to a partition are seen by the library but may or may not be seen by the partition.
20982 The web browser may intermittently
fail to display menus properly. Alternatively, some elements on a few of the pages may obscure some menu items when viewing in Internet Explorer.
Known Issues 5
Make sure the I/E station is empty before performing a library firmware upgrade. To recover from this error, empty the I/E stations, change the number of I/E stations, then reset the number of I/E stations back to the number you want.
Refresh the browser.
Page 6
Release Notes Document 6-01378-16 June 2010
Change Request Number
Service Request Number
Description Workaround
21746 An LTO-4 tape drive failed to unload
the cleaning cartridge after a tape drive cleaning was performed. “Older” cleaning tapes take longer than 3 minutes to clean, so the library times out while waiting for the cleaning cartridge to unload. Cleaning cartridges manufactured prior to 2004 may be identified by the cartridge designation of “Ultrium 1 Cleaning Cartridge” as opposed to the newer universal cleaning cartridge designation of “Cleaning Cartridge For Use With All Ultrium Drives.”
22766 The library may log you off after you
change the time or time zone.
22967 When upgrading a library with a
Model 2 robot to firmware version 570G, the library may generate a RAS ticket T124 (Robotics Hardware Error ­RCB).
Perform a manual move of the cleaning cartridge from the tape drive to the I/E station and remove the cleaning cartridge from the library. Do not reuse the cleaning cartridge because the same problem is likely to reoccur. Instead, use a new cleaning tape.
Log back in.
Explanation: The problem has been fixed
in the code for the 570G release, but because the problem resides in previous code versions, you may encounter this issue when upgrading from a previous version to this version.
Workaround: Leave the library powered
on for 20 minutes after the ticket was posted to allow the picker to recover. If you open a library door or power cycle the library during this time, the picker may become inoperable and require replacement.
6 Known Issues
Page 7
Release Notes
Document 6-01378-16
June 2010
Change Request Number
Service Request Number
Description Workaround
23407 The library presents misleading I/E
station failure messages in the following two instances:
• Using the web client, select a tape to export. Open the I/E station, or open and close the I/E station and click
Apply before the rescan completes.
The following failure message displays: “The Destination slot is Full.”
• Insert a cartridge into the I/E station and assign it to a partition. On the web client, go to the Import Media page and select the media to import. Open the I/E station and then click on the
Apply button. The following
failure message displays: “Command not completed. The library is Not Ready.”
When performing export/import media operations, do not interfere with the operation by opening and closing the I/E station.
In both these cases, the problem is that the I/E slot is inaccessible, not the error message that is displayed.
23786 Diagnostic tests run on HP tape drives
are invalid.
25651 If a tape drive firmware update fails
when using a firmware update method other than autoleveling, the library may incorrectly generate RAS ticket
T112 - Invalid T ape Drive Firmware Image
in addition to correctly generating RAS ticket
T109 - Tape Drive Firmware
Update Failure.
25964 SR1070246 If a library is upgraded and fails to
initialize upon reboot, the snapshot name will be incorrect.
26574 The library may lose communication
with a control path tape drive when upgrading library firmware. The library generates RAS ticket
Drive Sled Communication Failure
T021 -
.
Do not run diagnostic tests on HP tape drives. These tests only apply to IBM tape drives.
Ignore T112, and follow the resolution steps for T109.
Snapshot information is correct other than the name. Correct the hardware issue that is causing library not to initialize.
Follow the resolution steps for RAS ticket T021.
Known Issues 7
Page 8
Release Notes Document 6-01378-16 June 2010
Change Request Number
Service Request Number
Description Workaround
27092 Occasionally the FC I/O blade serial
number is reported incorrectly on the Tools - I/O Blade Information screen (
Tools > I/O Blade Info).
27320 The library user interface lacks a means
to initiate a failover/failback operation.
28022 IBM SAS drive port lights do not come
on when the tape drive is connected.
28047 HP LTO tape drives do not report
cleaning count accurately. HP LTO-5 cleaning count is reported as one less than it should be; HP LTO-4 cleaning count may be reported as several less than it should be.
If the serial number ends with invalid characters, ignore the invalid characters. The rest of the serial number is correct.
Once the library has failed over, you can perform a manual failback as follows:
1) From the Web client, navigate to Setup > Control Path
2) Set the current control path drive as
.
the failover drive, and set the current failover drive as the control path drive.
3) Click Apply.
4) Switch the settings back to how they
were originally.
5) Click Apply.
The port lights are not enabled as of this release. They will be enabled in a future release.
This is due to a known issue with HP LTO-4 and LTO-5 tape drives.
28240 When an HP LTO-5 tape drive is set to
8 Gb/s but connected to a lower-speed HBA, the drive’s amber link LED stays lit even after the drive is disconnected from the HBA. The link LED should turn off.
28408 IBM LTO-5 drives failed firmware
upgrade on a library that had an FC I/O blade installed. Some of the drives that failed the upgrade were connected to the FC I/O blade.
8 Known Issues
Remove and re-seat the tape drive.
Try the firmware upgrade operation again.
Page 9
Release Notes
Document 6-01378-16
June 2010

Firmware Versions 0

The table below lists firmware code for the last several releases.
Board Scalar i500 Li
brary
Release
SP6 586G.GS001 6.86 655Q.GU005 with
i6.1 585G.GS003 6.86 655Q.GU005 with
i6 580G.GS003 6.80 650Q.GU014 with
SP5.5 572G.GS002 6.73 630Q.GU008(app)
i5.1 571G.GS002 6.73 630Q.GU008 with
i5 570G.GS025 6.73 630Q.GU008 with
i4 520G.GS003 6.66 610Q.GU005 with
i3.1 500G.GS004 6.53 591Q.GU004 with
Firmware
ort
Supp
Package
(BSP) UDS Firmware
30A.GU001 boot
4
30A.GU001 boot
4
30A.GU001 boot
4
30A.GU001(boot)
4
30A.GU001 boot
4
30A.GU001 boot
4
30A.GU001 boot
4
30A.GU001 boot
4
Fibre­Channel I/O Blade Firmware
V05100201
V05100201
V05100201
V05090501
V05090501
V05090501
V05080801
V05080201
i3 500G.GS002 6.52 590Q.GU001 with
30A.GU001 boot
4
Firmware Versions 9
V05080201
Page 10
Release Notes Document 6-01378-16 June 2010

Documentation 0

Documentation pertaining to this product is located at:
http://www.quantum.com/ServiceandSupport/ SoftwareandDocumentationDownloads/SI500/Index.aspx#Documentation
Document Number Document Title
6-01733-xx Scalar i500 Site Planning Guide
6-01210-xx Scalar i500 User’s Guide
6-01811-xx Scalar i500 User’s Guide Addendum
6-01741-xx Scalar i500 Getting Started Guide
6-01385-xx Scalar i500 Unpacking Instructions (5U)
6-01524-xx Scalar i500 Unpacking Instructions (9U)
6-01525-xx Scalar i500 Unpacking Instructions (14U)
6-01370-xx Scalar i500 Basic SNMP Reference Guide
6-00423-xx Quantum Intelligent Libraries SCSI Reference Guide
6-01317-xx Quantum Intelligent Libraries SMI-S Reference Guide
6-00676-xx Quantum SNC Firmware 4 and 5 User’s Guide
6-01739-xx Scalar i500 Library Firmware Upgrade Instructions
6-01740-xx Scalar i500 Tape Drive Firmware Upgrade Instructions
6-01844-xx Library Service Utility Installation Instructions
6-00618-xx System, Safety, and Regulatory Information Guide
6-66914-xx Scalar i500 Generic CRU Instruction Sheet
To order a copy of the source code covered by the Open Source Licenses, contact the
Quantum Technical Assistance Center. Refer to
Contacting Quantum below.
10 Documentation
Page 11
Release Notes Document 6-01378-16 June 2010

Contacting Quantum 0

More information about this product is available on the Service and Support website at contains a collection of information, incl questions (FAQs). You can also access software, firmware, and drivers through this site.
www.quantum.com/support. The Service and Support Website
uding answers to frequently asked
For further assistance, or if training is desired,
contact Quantum:
North America and Mexico 1-800-827-3822
Europe, Middle East, and Africa 00800-9999-3822
Worldwide Support
http://www.quantum.com/ ServiceandSupport/Contacts/ worldwide/Index.aspx
To open a Service Request: www.quantum.com/osr
Quantum Corporation www.quantum.com
Made in the USA.
Quantum Corporation provides this publication “as is” without warranty of any kind, either express or implied, including but not limited to the implied warranties of merchantability or fitness for a particular purpose. Quantum Corporation may revise this publication from time to time without notice.
COPYRIGHT STATEMENT
© Copyright 2010 by Quantum Corporation. All rights reserved.
Your right to copy this document is limited by copyright law. Making copies or adaptations without prior written authorization of Quantum Corporation is prohibited by law and constitutes a punishable violation of the law.
TRADEMARK STATEMENT
Quantum, the Quantum logo, and Scalar are registered trademarks of Quantum Corporation.Other trademarks may be mentioned herein which belong to other companies.
11
Loading...