Quantum SCALAR 50 User Manual

Page 1
Quantum Scalar 50
Chassis Repacking Instructions
Introduction 3
Removing the Library from the Rack 3
Installing the Internal Hand Restraint 6
Packing the Library for Shipment 9
Document 81-81772-01 A01, July 2007 1
Page 2
Quantum Scalar 50 Chassis Repacking Instructions Document 81-81772-01 A01 July 2007
Made in the USA.
Quantum Corporation provides this publication “as is” without warranty of any kind, either express or implied, including but not limited to the implied warranties of merchantability or fitness for a particular purpose. Quantum Corporation may revise this publication from time to time without notice.
COPYRIGHT STATEMENT
© Copyright 2007 by Quantum Corporation. All rights reserved.
Your right to copy this document is limited by copyright law. Making copies or adaptations without prior written authorization of Quantum Corporation is prohibited by law and constitutes a punishable violation of the law.
TRADEMARK STATEMENT
Capacity on Demand (CoD), Crosslink Mechanism, DLT, DLTSage, DLTtape, Super DLTtape, Performance on Demand, (PoD), PRISM, PRISM Storage Architecture logo, SiteCare, StackLink, StorageCare, SuperLoader, and ValueLoader are all trademarks of Quantum Corporation. Quantum, the Quantum logo, and the DLTtape logo are all registered trademarks of Quantum Corporation.
Other trademarks may be mentioned herein which belong to other companies.
2
Page 3
Quantum Scalar 50 Chassis Repacking Instructions
Document 81-81772-01A01
July 2007

Introduction 0

This document explains how to repack the Quantum Scalar 50 library. Follow these instructions carefully to ensure the library is shipped properly.
Note: All Scalar 50 documentation is located on the Scalar 50
Documentation CD included in the library accessory kit.
Caution: This procedure requires the packing materials originally sent
with the library for proper shipment. If you do not have the library packing materials, contact Quantum customer support for replacement packaging
This procedure consists of the following steps:

Removing the Library from the Rack

Installing the Internal Hand Restraint
(800) 284-5101.
Packing the Library for Shipment
Removing the Library from the Rack 0
To remove the Scalar 50 library from the rack:
Note: You must remove all tape cartridges from the library prior to
parking the library hand for shipment.
1 Using the OCP, open the front doors, remove both tape cartridge
magazines, and remove any tape cartridges from the fixed bins or FlexLink™ (refer to the Quantum Scalar 50 User’s Guide PN 81-81768 for information on OCP operation and bin locations).
After removing the tape cartridge magazines and closing the doors, the library inventories all possible tape cartridge locations (magazines, fixed slots, Flexlink, and tape drives). This process takes several minutes.
2 From the Library Operations screen on the OCP, select Park for Shipping.
The library shuts down automatically.
Note: If there are tape cartridges in the library, the system will NOT
park the library hand. You must remove all tape cartridges from the system prior to parking the library hand.
Introduction 3
Page 4
Quantum Scalar 50 Chassis Repacking Instructions Document 81-81772-01A01 July 2007
3 From the back of the library, disconnect all power, Ethernet, and SCSI
cables from the library and note their locations for later reinstallation.
Warning: This unit has more than one power supply cord.
4 To remove the library chassis from the rack (see figure 1):
Note: Refer to the Scalar 50 Quick Start Guide (PN 81-81767) for
a Loosen the captive screws securing the tape drives to the chassis and
remove the tape drive(s) from the back of the library.
b Loosen the captive screw securing the power supplies to the chassis
and remove the power supplies from the back of the library.
c Remove Phillips screws securing each side of the chassis to the rack
mounting rails and remove two Allen screws securing both clamps on the back of the library.
Disconnect all power supply cords before servicing to avoid electric shock.
additional Scalar 50 rack mount information.
d Remove the library from the rack.
Warning: At least two people are required to move the library
chassis.
4 Removing the Library from the Rack
Page 5
Figure 1 Removing the
Power supplies
Tape drives
Right magazine
Scalar 50 Library
Quantum Scalar 50 Chassis Repacking Instructions
Document 81-81772-01A01
July 2007
Removing the Library from the Rack 5
Page 6
Quantum Scalar 50 Chassis Repacking Instructions
Right magazine door
Door releases
Left magazine door
Document 81-81772-01A01 July 2007

Installing the Internal Hand Restraint 0

To ensure that the internal hand within the library is not damaged, you must install the internal hand restraint.
Caution: Failure to install the hand restraint may void your warranty.
To install the internal hand restraint:
1 Place the library on a flat surface approximately waist high:
Note: If the bottom FlexLink cover has been removed, replace it
before shipping the library back to Quantum.
2 Insert the emergency access tool included with the accessory kit into the
release holes and trip the magazine door release for both the right and left magazine doors (see
figure 2).
Figure 2 Opening the Right and Left Magazine Access Doors
The magazine access doors open.
6 Installing the Internal Hand Restraint
Page 7
Quantum Scalar 50 Chassis Repacking Instructions
Document 81-81772-01A01
July 2007
3 If the library is not operational and the Park for Shipping command was
not executed, grasp the hand and gently move it to the front of the library.
Caution: Take standard ESD precautions when working within the
library chassis.
Note: If there are any cartridges in the fixed bins, you can remove
them now.
4 Install the robotic restraint over the hand and secure with two thumb
screws
figure 3.
Installing the Internal Hand Restraint 7
Page 8
Quantum Scalar 50 Chassis Repacking Instructions
Hand restraint
Thumb
screws
Hand restraint
installed
Document 81-81772-01A01 July 2007
Figure 3 Installing the Hand Restraint
5 Replace the tape magazines and close the front doors.
6 Install the thumb screw restraint on the left-hand side of the library
chassis (see
figure 4).
8 Installing the Internal Hand Restraint
Page 9
Figure 4 Installing the Restraining Bolt
Quantum Scalar 50 Chassis Repacking Instructions
Document 81-81772-01A01
July 2007
7 Install the tape drives, and power supplies previously removed in
Removing the Library from the Rack.
8 Install the tape cartridge magazines.

Packing the Library for Shipment 0

1 Carefully place the library into the antistatic bag.
2 Package the library into the shipping carton as shown in figure 5. Ensure
that the library chassis is placed in an antistatic bag before placing the library in the shipping carton.
Warning: At least two people are required to move the library
chassis.
Packing the Library for Shipment 9
Page 10
Quantum Scalar 50 Chassis Repacking Instructions
Shipping carton
Front bezel
Library chassis
Accessories kit
Lift point
Shipping materials
Shipping materials
Document 81-81772-01A01 July 2007
Caution: Lift the library chassis at the sides. Avoid putting the
Figure 5 Preparing the Library for Shipping
weight of the library chassis on the front bezel.
10 Packing the Library for Shipment
*81-81772-01 A01*
81-81772-01