8x8 CobraNet Enabled Signal Processor
Hardware Manual
*TD-000164-00*
TD-000164-00 rev.B
IMPORTANT SAFETY PRECAUTIONS & EXPLANATION OF SYMBOLS
The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to
the presence of uninsulated “dangerous” voltage within the product’s enclosure that may be of sufficient
magnitude to constitute a risk of electric shock to humans.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of
important operating and maintenance (servicing) instructions in this manual.
SAFEGAURDS
Electrical energy can perform many useful functions. This unit has been engineered and manufactured to
assure your personal safety. Improper use can result in potential electrical shock or fire hazards. In order
not to defeat the safeguards, observe the following instructions for its installation, use and servicing.
CAUTION: To reduce the risk of electric shock, do not remove the cover. No user-serviceable parts inside.
Refer servicing to qualified service personnel.
WARNING: To prevent fire or electric shock, do not expose this equipment to rain or moisture.
1- Maximum operating ambient temperature is 50°C (122°F).
2- Never restrict airflow through the device fan or vents. Please insure that the air intake and exhaust
vents are unobstructed.
3- When installing equipment into rack, distribute the units evenly. Otherwise, hazardous conditions
could be created by an uneven weight distribution.
4- Connect the unit only to a properly rated supply circuit. The RAVE 522aa is suitable for connection to
100 - 240 VAC, 47 - 440 hertz, with no special considerations other than the appropriate IEC power cord.
5- Reliable Earthing (Grounding) of rack-mounted equipment should be maintained.
LITHIUM BATTERY WARNING
THIS EQUIPMENT CONTAINS A NON-RECHARGEABLE LITHIUM BATTERY. LITHIUM IS A CHEMICAL
KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER OR BIRTH DEFECTS. THE NON-RECHARGEABLE LITHIUM BATTERY CONTAINED IN THIS EQUIPMENT MAY EXPLODE IF IT IS EXPOSED TO FIRE OR
EXTREME HEAT. DO NOT SHORT CIRCUIT THE BATTERY. DO NOT ATTEMPT TO RECHARGE THE NONRECHARGEABLE LITHIUM BATTERY.
FCC INTERFERENCE STATEMENT
NOTE: This equipment has been tested and found to comply with the limits for a class B digital device,
pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses, and can radiate radio
frequency energy and if not installed and used in accordance to the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by switching the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio or TV technician for help.
with the U.S. Patent and Trademark Office. All trademarks are the property of their respective owners.
2
Introduction
The RAVE 522aa provides the digital audio transport, and
signal processing needed to bind a group of amplifiers and
loudspeakers into an integrated functioning system. In conjunction with QSControl.net software, the RAVE 522aa
enables the user to design, test and deploy professional
audio reinforcement and distribution systems ranging in size
from one to hundreds of channels.
A standard Windows computer is the principle user-interface for controlling the overall RAVE/QSControl system.
However, the RAVE 522aa also offers a front panel interface
for accessing critical functions.
A single QSControl server computer can support several clients running QSC's latest Venue Manager software. Thus,
the sound system can be operated via several computers,
roaming wireless laptops, tablets, etc., all at the same time,
from anywhere a connection to the QSControl network is
available.
The QSControl network can also be managed from a single
computer running both the client and the server. Once all
devices in a system are configured, a computer is no longer
Don’t want to read the entire manual? Just
want to dig right in? Go to page 18....
required on that system’s network. All basic functions of the
RAVE 522aa continue to operate with or without a control
computer connected to the network.
Audio enters a RAVE 522aa either through analog line
inputs or from CobraNet source devices such as QSC's line
of RAVE digital audio routers. Any combination of 16 CobraNet channels (selected from up to 4 bundles of 32 channels)
can be routed into the 24 x 24 DSP engine. Any or all of the
24 DSP channels can also be routed to up to 32 CobraNet
channels on the network.
Unlike many configurable DSP boxes, the intrinsic processing latency of the RAVE 522aa is both short and fixed at
0.396 milliseconds. When analog input and analog outputs
are used, the total delay is 2.354 milliseconds. The delay
does not change regardless of the DSP configuration, unless
the configuration intentionally adds more delay.
The RAVE 522aa also supports the new optional low-latency
CobraNet feature that provides transport at only 2.66 milliseconds delay.
1- Power indicator
2- Diagnostic indicator
3- Network status indicators
4- Multi-function push buttons
5- Display
6- Rotary select/accept knob
7- Safe Mode push switch (recessed)
8- Analog outputs
9- Analog inputs
See page 14 for detailed descriptions.
10- Relay outputs
11- Logic outputs
12- Omni inputs
13- RS-232 port
14- Network status indicators
15- QSControl 10BaseT receptacle
16- CobraNet 100BaseTx receptacle
17- IEC power inlet
3
Introduction (continued)
Both software and firmware can be easily updated over the
network. In the future, QSC will be adding new capabilities
to both RAVE and QSControl.net. Our latest code releases
and access to up-to-date information on RAVE and QSControl.net are available at www.qscontrol.net. We invite you
to visit us there.
We've applied our many years experience in supporting
high-end installed sound with our previous system-building
Block Diagram
products such as RAVE, QSControl, CM16a, DSP-3, DSP-4,
and DSP-30. The RAVE 522aa brings all that technology
together in one compact, powerful, easy to use system. We
are confident that your new RAVE 522aa will provide years
of dependable service and we hope it will help you, the system designer and implementer, to express your creative
audio system ideas.
4
Introduction - Networking the RAVE 522aa
The RAVE 522aa has two RJ-45 network connection ports on the rear panel. One port is labeled "QSControl" and supports standard
10BASE-T Ethernet. The other port is labeled "CobraNet" and supports 100BASE-TX, also known as "Fast Ethernet". In the following
sections, we describe the use of these ports and show example network connection schemes.
The RAVE 522aa supports two distinct kinds of network activity; the first is audio transport via CobraNet, and the second is QSControl.net. The user can choose to install one network for CobraNet traffic and a second separate network for QSControl traffic. We call
this the "Two Wire Interface". Alternately, it is possible to run both QSControl data and audio traffic via the CobraNet port. In this case
the QSControl port is unused. We call this the "Single Wire Interface".
Under the most demanding real-time control conditions and when using the lowest latency CobraNet settings, users may experience
better QSControl performance using separate networks, especially when displaying a great many real-time meters. For most applications, separate networks won't provide any discernible benefits and will of course cost more. We therefore recommend using the Single Wire Interface when running CobraNet.
If your application uses only analog I/O without CobraNet, then you should use the QSControl port for QSControl traffic and ignore the
CobraNet port.
Why CobraNet Needs Special Treatment:
Ordinary Ethernet traffic has no guaranteed time of delivery. Packets of information may arrive at their destination out of order and
some may be delayed more than others. This is fine for E-mail and even for downloading MP3 files over the Internet. Everything ends up
properly reassembled at the destination, but how long this takes will vary according to network loading, span, etc. In contrast, CobraNet is "real time" - it delivers audio with a minimal, consistent transmission delay. CobraNet is designed to use as much of conventional
networking technology as possible while providing both guaranteed time of delivery and isochronicity - maintaining a phase-locked
sample-accurate clock across the entire network. These requirements mean that ordinary unregulated Ethernet data cannot be freely
mixed with CobraNet information. The two can coexist on the same wire, but only by adhering to the proper rules.
To learn more about CobraNet and appropriate network topologies, please visit http://www.qscaudio.com/products/network/
resources.htm and http://www.peakaudio.com/CobraNet/background.html.
Notes on Network Systems Design:
As with any communications system, the reliability and performance of a local area network is intimately related to the designer's skill
and knowledge in implementing a topology that is robust, efficient and standards-compliant. Proper network design is even more critical in distributed multimedia systems. Therefore, it is important for the system designer to realize that some conventional network
practices must be avoided. Although each network design is unique and may carry its own performance requirements, compliance to
the following three points will assist in building an audio network that is trouble free and efficient.
First, audio and conventional data communications deliveries should not exist on the same LAN or VLAN. The exception to this is the
RAVE 522aa Single Wire Interface, which offers a solution for converging audio and QSControl.net onto the same LAN or VLAN. However, conventional communications, such as corporate networks, print services, e-mail and Internet access, should not exist alongside
CobraNet audio and QSControl.net on the same LAN or VLAN. Further, CobraNet audio and QSControl.net data should not exist
together on the same LAN or VLAN when implementing the Two Wire Interface. This is not to say that conventional communications
cannot share the same network hardware with a RAVE 522aa. In fact, common network hardware, such as managed Ethernet switches
and media converters, can service both RAVE 522aa products and conventional data communications equipment so long as the managed switch or media converter are partitioned into separate network domains. This is normally done by configuring a separate VLAN
for each data type. (Some switches may allow individual port assignments or support partitions through DIP switch selection.)
Second, CobraNet audio must traverse either a repeater domain or a network switch domain. The point here is that the CobraNet port
on a RAVE 522aa must connect directly to, and only to, either a repeater LAN or a switched Ethernet LAN. Hybrid networks containing
both repeaters and switches are not permitted on the audio segment. Connecting the CobraNet port to a repeater that is in turn connected to a network switch poses an illegal and non-compliant condition. We recommend always connecting the QSControl and/or
CobraNet port(s) directly to network switch ports.
5
Third, the RAVE 522aa and QSControl.net system are targeted at network switch deployments. The consumer costs of Ethernet
switches have continued to fall over the last several years and are now comparable with repeaters on a per port basis. In addition, the
sophistication and scalability of network switches make them ideal for new installations. However, we do realize that designers may
wish to add RAVE products to existing audio network installations that are built on repeater LAN topologies. This applies primarily to
existing CM16a and RAVE networks. For this very reason we continue to support connectivity to network repeater hardware with the
RAVE 522aa. Support for network repeaters exist only with the Two Wire Interface. That is to say that the QSControl port and the
CobraNet port must be connected to separate repeater LANs. Even when properly configured, audio channel capacity is severely limited and both audio and control network expansion is limited by the respective wire speed of each segment. In other words, scalability
ceases to exist when bandwidth demands on the QSControl segment approach 10 Mbps and demand on the CobraNet segment
approaches 100 Mbps. Obviously, we recommend taking advantage of switch network technology whenever possible.
It should be noted here that while the CobraNet port on a RAVE 522aa is restricted to repeater LAN or switch LAN deployments,
QSControl.net is a TCP/IP standards-compliant network system and therefore supports operation on network repeaters, switches and
routers. When implementing the Two Wire Interface, the QSControl.net segment does not require a single topology data path and
therefore repeaters, switches and routers may be assembled on the LAN in a hybrid fashion.
To learn more about network design rules and system compliance visit the QSC network resources page at http://www.qscaudio.com/
products/network/resources.htm. To learn more about CobraNet design requirements and to obtain the CobraCAD system design utility
visit the Peak Audio website at http://www.peakaudio.com/CobraNet/Network_Design.html.
All of this may seem daunting if you are new to networking. However, it all boils down to connecting a few simple cables between various networking devices. Most of the time it "just works". QSC helped pioneer CobraNet with our RAVE ™ products and there are hundreds of installations all over the world, in theme parks, hotels, stadiums - everywhere. They run hum-free, sound great and are very
reliable.
The following examples will help get you started, but they just scratch the surface of what can be achieved with advanced networking…
Example #1 - QSControl.net X-over mode:
This is the simplest connection you can make between the RAVE 522aa and your computer. You use a CAT-5 crossover cable connected
between the RAVE QSControl port and your computer's Network Interface Card, (NIC). No network switch is required. With QSControl.net server and client software installed and running on your computer you will be able to completely set up your RAVE 522aa.
6
Example #2 - CobraNet X-over mode:
This is the simplest connection you can make between the RAVE 522aa and any of the other RAVE/BASIS models. You use a CAT-5
crossover cable connected between the CobraNet ports of each unit. No network switch is required. This connection allows audio to
pass between the two RAVE/BASIS units over CobraNet.
Combining example 1 and 2 lets you setup one unit at a time, much as you would have to do using a point-to-point RS232 connection,
while passing audio between them, all without a network switch. However, you would have to physically connect your computer first
to one unit, and then to the other. With this elementary connection you don't have a true network. It is like making RS-232 connections - except that performance is better.
All the other examples are of proper networks and all require a network switch. On a proper network, you have direct access to all
units all of the time without having to physically switch between them. You still get the great performance of TCP/IP over Ethernet.
(And we believe QSC's advanced networking software provides the best performance of any networked audio control system available today including Ethernet based systems from competitors.)
7
Example #3 - Single Wire Interface:
Here all QSControl and CobraNet traffic shares the same single CAT-5 cable between the RAVE 522aa and an unmanaged Ethernet
switch. The QSControl.net system manages traffic flow efficiently and reliably so that all audio and control data is delivered to its
appropriate destination anywhere on the network. This configuration works well when CobraNet audio deliveries are point to point.
Though the example shows only two RAVE/BASIS units, as many devices may be connected as there are available switch ports. All
units will be able to communicate simultaneously with the computer. All will have access to CobraNet audio. Switches can be connected to other switches to build larger networks; all of the normal networking principles apply. (Note: there must be at least two
CobraNet devices, one source and one destination, online for any data to come out of the CobraNet port)
8
Loading...
+ 18 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.