EXPLANATION OF SYMBOLS
The term “WARNING!” indicates instructions regarding personal safety. If the instructions are not followed the result may be bodily injury or
death.
The term “CAUTION!” indicates instructions regarding possible damage to physical equipment. If these instructions are not followed, it may
result in damage to the equipment that may not be covered under the warranty.
The term “IMPORTANT!” indicates instructions or information that are vital to the successful completion of theprocedure.
The term "NOTE" is used to indicate additional useful information.
The intent of the lightning flash with arrowhead symbol in a triangle is to alert the user to the presence of un-insulated "dangerous"
voltage within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to humans.
The intent of the exclamation point within an equilateral triangle is to alert the user to the presence of important safety, and operating
and maintenance instructions in this manual.
IMPORTANT SAFETY INSTRUCTIONS
WARNING!:TO PREVENT FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with a dry cloth.
7. Do not block any ventilation opening. Install in accordance with the manufacturer's instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus that produce heat.
9. To reduce the risk of electrical shock, the power cord shall be connected to a mains socket outlet with a protective earthing connection.
10. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A
grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided
plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
11. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from
theapparatus.
12. Only use attachments/accessories specified by the manufacturer.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as powersupply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
15. The appliance coupler, or the AC Mains plug, is the AC mains disconnect device and shall remain readily operable after installation. On units
equipped with powerCon® connectors, the AC Mains disconnect device is the AC Mains plug only; do not use the appliance coupler.
16. Adhere to all applicable, local codes.
17. Consult a licensed, professional engineer when any doubt or questions arise regarding a physical equipment installation.
18. Do not use any aerosol spray, cleaner, disinfectant or fumigant on, near or into the apparatus. Clean only with a dry cloth.
19. Do not unplug the unit by pulling on the cord, use the plug.
20. Do not submerge the apparatus in water or liquids.
21. Keep ventilation opening free of dust or other matter.
A-TD-001522-01
2
Page 3
Maintenance and Repair
WARNING!:Advanced technology, e.g., the use of modern materials and powerful electronics, requires specially
adapted maintenance and repair methods. To avoid a danger of subsequent damage to the apparatus, injuries to persons
and/or the creation of additional safety hazards, all maintenance or repair work on the apparatus should be performed only
by a QSC authorized service station or an authorized QSC International Distributor. QSC is not responsible for any injury,
harm or related damages arising from any failure of the customer, owner or user of the apparatus to facilitate those repairs.
FCC Statement
NOTE:This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the
FCCRules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
RoHS STATEMENT
The QSC CXD8.4Q, CXD8.4Qn, CXD8.8Q and CXD8.8Qn amplifiers are in compliance with European Directive 2011/65/EU – Restriction of
Hazardous Substances(RoHS2).
The QSC CXD8.4Q, CXD8.4Qn, CXD8.8Q and CXD8.8Qn amplifiers are in compliance with “China RoHS” directives. The following chart is provided
for product use in China and its territories:
QSC CXD8.4Q, CXD8.4Qn, CXD8.8Q and CXD8.8Qn Ampliers
(O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part
is below the limit requirement in SJ/T11363_2006.)
X: 表明这些有毒或有害物质在部件使用的同类材料中至少有一种含量是在 SJ/T11363_2006 极限的要求之上。
(X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials
used for this part is above the limit requirement in SJ/T11363_2006.)
(Toxic or hazardous Substances and Elements)
铅
(Pb)
XOOOOO
XOOOOO
汞
(Hg)
镉
(Cd)
六价铬
(Cr(vi))
多溴联苯
(PBB)
多溴二苯醚
(PBDE)
Warranty
For a copy of the QSC Limited Warranty, visit the QSC website at www.qsc.com
A-TD-001522-01
3
Page 4
Unpacking
There are no special unpacking instructions. You may want to keep the shipping material for the unlikely event that the amplifier should need
returning for service.
Package Contents
• Quick-Start Guide TD-000476
• Safety Sheet TD-000420
• Amplifier
• Power Cord
• Euro-style Connector Plug, 3-pin (8) (CXD8.4Q and CXD8.8Q only)
• Euro-style Connector Plug, 8-pin (2)
• Euro-style Connector Plug, 3.5 mm, 16-pin (1)
Features
Amplifier Front Panel
Refer to
Amplifier Rear Panel
Refer to
"Amplifier Controls and Indicators" on page 8.
Figure 1 (CXD8.4Q / CXD8.8Q shown)
NOTE: The CXD8.4Qn and CXD8.8Qn models do not have the analog inputs (Item 3 below).
134567928
— Figure 1 —
1. RJ-45 Q-SYS Q-LAN A/B
2. GPIO Euro-style Connector, 16-pin
3. Analog Inputs (1-8) – Eight 3-pin Euro-style Connectors (Only
CXD8.4Q and CXD8.8Q models.)
4. Outputs (A-H) – Two 8-pin Euro-style Loudspeaker Connector
Installation
The following steps are written in the recommended installation order.
5. Cooling fan inlet (do not block)
6. AC Power Switch
7. Locking IEC Power Connection
8. Rear Rack-mount Bracket
9. Front Rack-mount Brackets
Rack-Mount the Amplifier
The CXD-Q Series amplifiers are designed to be mounted in a standard rack-mount unit. The amplifiers are 2RU high, and 381 mm (15 in) deep.
1. Secure the amplifier in the rack with eight screws (not supplied), four in front, four in back. For complete instructions, refer to TD-000050
"Rear Rack Ears Installation Guide" which can be found on the QSC Website (www.qsc.com)
CAUTION!:Be sure that nothing is blocking the front or rear ventilation openings, and that each side has a minimum of
2cmclearance.
A-TD-001522-01
4
Page 5
Inputs
Balanced
—
+
Unbalanced
—
+
+
-
Connect the amplifier LAN A, and if available, LAN B, to the Q-LAN network (
requirements and connection detail.
Figure 4
). Refer to your Q-SYS documentation for network
— Figure 2 —
— Figure 3 —
— Figure 4 —
The analog inputs are converted to digital audio in the CXD8.4Q and
CXD8.8Q amplifiers and then routed to the Q-SYS Core over the network.
The digital signals show up in Q-SYS Designer at the CXD-Q input
component where they can be routed as needed. Refer to the Q-SYS
documentation.
1. Make sure your audio source devices are powered off.
2. Wire the audio mic- or line-level source to up to eight Euro-style
connectors (supplied), you can use either balanced inputs (
or unbalanced inputs (
Figure 3
).
Figure 2
-
)
+
-
+
-
+
-
+
-
+
-
+
3. Plug the connectors into the appropriate receptacles (Routeable
Inputs 1, 2, 3, 4, 5, 6, 7, 8)
GPIO
Refer to
"GPIO" on page 13
Figure 4
and
Figure 5
.
for details about the GPIO feature.
— Figure 5 —
Outputs and Output Configuration
The CXD-Q amplifiers have two sets of four-channel outputs that are configured independently. The configuration of the amplifier is defined in
Q-SYS designer software and is "pushed" into the physical amplifier when the Name and Type of amplifier in the design matches the Name and
Type of physical amplifier. When the output configuration of the amplifier changes, the Outputs to the loudspeakers change accordingly.
-
+
Use the diagrams shown in
Figure 6
thru
Figure 9
connect the wiring based on your configuration. After connecting the loudspeakers to the outputs, you may turn the amplifier on.
CAUTION!:Before turning the amplifier on, double check your output connections to be sure they are connected properly based
on the output configuration specified in Q-SYS Designer.
If you change the output configuration of the amplifier you must change the loudspeaker connections before applying power to the
amplifier!
After a change of the output configuration, the amplifier re-boots and all outputs are muted. You must press the Mute All button in the
Q-SYS Amp Output component, or unmute all channels on the front panel of the amplifier.
Figure 6
thru
Figure 9 are examples of the three types of output configurations: Separate, Bridged and Parallel. The tables to the right and left
of the loudspeaker connections (rear panel of the amplifier) give all the possible configurations and their connections.
A-TD-001522-01
as a reference for planning your loudspeaker configuration. Refer to
5
Figure 10
for how to
Page 6
Separate Channels (A B C D) and (E F G H)
For Separate Loudspeakers
Use eight 2-wire cables, connect to:
• T1+/T2- (Loudspeaker A / E)
• T3+/T4- (Loudspeaker B / F)
• T5+/T6- (Loudspeaker C / G)
• T7+/T8- (Loudspeaker D / H)
CHANNEL CONFIGURATION
Q A
Q B
4 Channels: A B C D
Channel Configuration Locked to Design
Q C
Q D
CHANNEL CONFIGURATION
Q E
Channel Configuration Locked to Design
Q G
Q F
4 Channels: E F G H
Q H
— Figure 6 —
Bridged (A+B) and Separate (C D) and (E F G H) Channels
For A+B (Bridged) One Loudspeaker
Use one 2-wire cable connect to:
• T1+/T3- (Loudspeaker A+B)
For C D (E F G H) (Separate) Two and Four Loudspeakers
Use six 2-wire cables, connect to:
• T1+/T2- (Loudspeaker E)
• T3+/T4- (Loudspeaker F)
• T5+/T6- (Loudspeaker C / G)
• T7+/T8- (Loudspeaker D / H)
CHANNEL CONFIGURATION
Q A+B
3 Channels: A+B C D
Channel Configuration Locked to Design
Q C
Q D
CHANNEL CONFIGURATION
Q E
Channel Configuration Locked to Design
Q G
Q F
4 Channels: E F G H
Q H
BRIDGED
CH A+B
T1+ T3-
— Figure 7 —
OUTPUTS TO SPEAKERSOUTPUTS TO SPEAKERS
-
CH D
+
-
CH C
+
-
CH B
+
-
CH A
+
OUTPUTS TO SPEAKERSOUTPUTS TO SPEAKERS
-
CH D
+
-
CH C
+
-
CH B
+
-
CH A
+
T8
T1
T7
T2
T6
T3
T5
T4
T4
T5
T3
T6
T2
T7
T1
T8
T8
T1
T7
T2
T6
T3
T5
T4
T4
T5
T3
T6
T2
T7
T1
T8
+
CH E
+
CH F
+
CH G
+
CH H
-
+
CH E
+
CH F
+
CH G
+
CH H
-
Two Pair of Parallel Channels (AB CD) and two Pair of Parallel Channels Bridged (EF + GH)
AB (Parallel) CD (Parallel) For Two Loudspeakers
Use two 2-wire cables, connect to:
• T1+/T2- (Loudspeaker AB)
• T5+/T6- (Loudspeaker CD)
EF (Parallel) Bridged with GH (Parallel) For One Loudspeaker
Full power to one loudspeaker
Use one 2-wire cable, connect to:
• T1+/T5- (Loudspeaker EF+GH)
CHANNEL CONFIGURATION
Q AB
2 Pair of Paraller Channels: AB CD
Channel Configuration Locked to Design
Q CD
A-TD-001522-01
CHANNEL CONFIGURATION
Q EF+GH
1 Channel: EF+GH
Channel Configuration Locked to Design
CH CD
T5+ T6-
CH AB
T1+ T2-
— Figure 8 —
6
OUTPUTS TO SPEAKERSOUTPUTS TO SPEAKERS
-
CH D
+
-
CH C
+
-
CH B
+
-
CH A
+
T8
T1
T7
T2
T6
T3
T5
T4
T4
T5
T3
T6
T2
T7
T1
T8
+
CH E
+
CH F
+
CH G
+
CH H
-
CH EF+GH
T1
+
T5-
Page 7
Parallel Channels (ABCD) and (E F G H)
CHANNEL CONFIGURATION
1 Channel: A B C D
Channel Configuration Locked to Design
Q ABCD
CH ABCD
T3
+
T4
-
CH D
CH A
CH B
CH C
+
+
+
+
-
-
-
-
T8
T5
T6
T7
T4
T1
T2
T3
CH E
CH H
CH G
CH F
+
+
+
+
-
-
-
-
T1
T4
T3
T2
T5
T8
T7
T6
OUTPUTS TO SPEAKERSOUTPUTS TO SPEAKERS
CHANNEL CONFIGURATION
Channel Configuration Locked to Design
Q EFGH
1 Channel: E F G H
CH EFGH
T1
+
T3
+
T5
+
T7
+
T2
-
T4
-
T6
-
T8
-
In 4-1 Parallel (ABCD or EFGH) only
T1+, T3+, T5+, and T7+ are electrically the same point
T2-, T4-, T6-, and T8- are electrically the same point
SETTINGS CAN BE
CONFIGURED FOR
70V, 100V AND
200V DIRECT
OUTPUT.
For One Loudspeaker
Full power to one loudspeaker; Use one 2-wire cable, connect to:
• T3+/T4- (Loudspeaker ABCD)
For Multiple Loudspeakers
Full power for multiple loudspeakers in parallel Use up to four 2-wire
cables, connect to:
• T1+/T2- (Loudspeaker E)
• T3+/T4- (Loudspeaker F)
• T5+/T6- (Loudspeaker G)
• T7+/T8- (Loudspeaker H)
— Figure 9 —
Connect the Loudspeakers
1. Connect the loudspeaker wiring to the 8-pin Euro-style connector as
needed for your amplifier's configuration.
2. Install the female 8-pin Euro-style connector onto the male connector
on the rear of the amplifier as shown in
Figure 10
.
3. Use a Phillips screwdriver to secure the connector.
AC Mains
WARNING!:When the AC Power is on, there is a
potential of having dangerous voltage at the output
terminals on the rear of the amplifier. Use caution not to
touch these contacts. Turn off the AC Mains disconnect
switch prior to making any connections.
1. Make sure the power switch on the rear of the amplifier is off.
2. Connect the IEC power cord to the AC receptacle. (
AC Power On
After connecting the outputs to the loudspeakers, you may turn the amplifier on.
Figure 11
)
— Figure 10 —
1. Make sure the output gain settings for all audio-source devices (CD Players, Mixers, Instruments,
etc.) are at the lowest output (max attenuation).
2. Turn on all audio sources.
3. Turn the AC Mains power switch on the back of the amplifier to ON. The amplifier starts in the state
it was in when power was removed. If the amplifier is in Standby or Mute All mode (Power button
LED solid red or blinking), press the Power button to change the amplifier to Run mode.
4. You can now bring up the outputs of your audio sources.
A-TD-001522-01
7
— Figure 11 —
Page 8
Amplifier Controls and Indicators
12
1
2
3
4
5
6
7
8
9
10
11
— Figure 12 —
13
14
15
16
17
1. Output Channel labels A, B, C, D, E, F, G, H
2. Output Channel Mute Buttons / LEDs (Red)
3. Output Channel Limiter LEDs (Red)
4. Output Channel -10 dB below maximum
amplifier output (Blue)
5. Output Channel -20 dB below maximum
6. Front-panel Power Button (Green/Red)
7. Output Channel Select Buttons / LEDs (Blue)
8. Input Channel Clip LEDs (Red)
9. FAULT LED (Amber)
10. Input Channel Signal-Present LEDs (Blue)
11. Input Channel labels 1, 2, 3, 4, 5, 6, 7, 8
amplifier output (Blue)
NOTE:The following scenarios assume that the amplifier is connected to the Q-SYS Core via Q-LAN. When the amplifier is
not connected to the Q-SYS Core, it is in a Fault mode, and not operational unless previously configured for fail-over or
standalone mode as part of a Q-SYS design. With the exception of the Power Switch, found on the rear panel, all of the following
controls are on the front panel.
Refer to
Figure 12
for location of front-panel controls.
Amplifier Modes
Off Mode
• Rear-panel power switch is off, the amplifier
is not operable. The power switch is the AC
Mainsdisconnect.
• The front-panel power button (6) is notilluminated.
• Turn the power switch to ON. The amplifier enters the
mode in which it was when power was removed – Run,
Mute All, orStandby.
Run Mode
• From Standby or Mute All mode, press and release the power
button on the front panel. The amplifier is in Run Mode.
• The power button (6) is illuminated green.
• The amplifier is fully operable; audio can pass.
Standby Mode
• From Mute All or Run mode, press and hold the power button (6)
on the front panel for approximately four seconds.
• The power button illuminates solid red.
• The amplifier is not operable; audio will not pass.
Mute All Mode
• From the Run Mode, quickly press and release the power button (6).
• The power button flashes red, all output Mute buttons (2) are red.
• The amplifier output is disabled, but the front panel is fullyoperable.
Power
Switch
Power
Button
12. LCD Graphic Display
13. NEXT Button
14. PREV Button
15. MASTER CONTROL Knob
16. ID Button
17. Pinhole Reset
Controls
SEL Buttons (7)
• Channel gain can be adjusted from the Q-SYS Designer software
or from the front panel of the amplifier.
• Use the SEL button to select one or more than one channel to change gain
settings. All selected channels will change at the same time.
• If two or more outputs are bridged or in parallel, pressing one button in the
group selects all channels in that bridged or parallel group.
NEXT (13) and PREV (14) Buttons
• Navigates forward and backwards through the screens.
NEXT
Master Control Knob (15)
• Adjusts the Gain for the selected channel or channels. At least
one channel must be selected.
• When one or more channels are selected, turn the Master Control knob to
jump to the Gain screen. After a few seconds with no activity, it returns to
the earlier screen.
• If there is more than one channel selected, and the gains for those channels
are different, the difference is maintained unless the gain is raised or
lowered to the limits for both channels.
ID Button (16)
• Press this button to display a screen with the amplifier's network
name. In addition, the ID buttons on the associated Q-SYS Amplifier
component and the associated Q-SYS Configurator item flashes. Press again,
or click one of the other ID buttons, to stop the flashing and exit the screen.
Pinhole Reset (17)
• Insert a paper clip or similar tool into the pinhole, press and
hold for 3 sec. then press the ID button to confirm and reset the amplifier.
Default settings include network settings to Auto, Amplifier Name,
password, and log file.
SEL
PREV
ID
A-TD-001522-01
8
Page 9
Input and Output Signal Flow
Q-LAN
Q-LAN
5612374
51234
CXD8.4Q and CXD8.8Q
Refer to
The CXD8.4Q and CXD8.8Q amplifiers have eight MIC/LINE inputs and eight (two blocks of four) amplified outputs on the rear of the amplifier. The
inputs and outputs are not physically (or electrically) connected in the amplifier giving you the flexibility to use any available source in Q-SYS for the
amplified outputs, and to route the inputs to any output. The inputs and outputs can be connected in your Q-SYS design as shown in
1. The analog inputs are converted to digital audio in the amplifier
2. The converted audio is then routed to the Q-SYS Core via Q-LAN (LAN A, LAN B).
3. The digital signals are brought into the design via the amplifier's Mic/Line Input component.
4. From the Mic/Line Input component the signals can be sent for processing and can be sent anywhere within the Q-SYS system.
5. In the Q-SYS Core digital audio signals (not necessiarily from the amp's inputs) are sent to the Q-SYS Amp Output component.
6. The digital audio is then sent from the Q-SYS Core via Q-LAN to the amplifier.
7. Digital signals are converted to analog, amplified and sent to outputs of the amplifier.
Figure 13
Figure 13
.
12V Phantom
2143
6587
ROUTABLE INPUTS
MIC/LINE
Amplifier
Rear Panel
Inputs
Mic/Line
Input
CXD-Q
Q-SYS
DSP
Routing
Q-SYS Core
— Figure 13 —
Amp Output
Amplifier-1
CXD-Q
QSC
Loudspeakers
Amplifier
Rear Panel
Outputs
The Q-SYS Amp Output component can have two to eight inputs/outputs depending on the configuration of the amplifier in Q-SYS Designer. The
desired configuration is selected in the Q-SYS Designer Properties menu for the amplifier. When the amplifier's configuration is changed, all of the
outputs are placed in a "mute all" state. You must un-mute all in the Amp Output component's control panel or on the amplifier's front panel.
CXD8.4Qn and CXD8.8Qn
Refer to
The CXD-Qn model amplifiers have no analog inputs. The input signal utilized to drive the amplifier channels must be virtually wired in Q-SYS
Designer. The CXD-Qn models have eight (two blocks of four) amplified outputs on the rear of the amplifier.
1. Digital audio is sent to the Q-SYS Core via Q-LAN (LAN A, LAN B).
2. In the Core, the signals can be sent for processing and can be sent anywhere within the Q-SYS system.
3. In the Q-SYS Core digital audio signals are sent to the Q-SYS Amp Output component.
4. The digital audio is then sent from the Q-SYS Core via Q-LAN to the amplifier.
5. Digital signals are converted to analog, amplified, and sent to the outputs of the amplifier.
Figure 14
Q-SYS
DSP
Routing
Q-LAN
The Amp Output component can have two to eight outputs depending on the configuration of the amplifier in Q-SYS Designer. The desired
configuration is selected in the Q-SYS Designer Properties menu for the amplifier. When the amplifier's output configuration is changed, all of the
outputs are placed in a "mute all" state. You must unmute all in the Amp Output component's control panel or on the amplifier's front panel.
A-TD-001522-01
Amp Output
Amplifier-1
CXD-Qn
Q-SYS Core
— Figure 14 —
QSC
Loudspeakers
Q-LAN
Amplifier Rear
Panel Outputs
9
Page 10
Screens
23451
1
2
3
4
Channel Configuration Screens
1.
Figure 15
CONFIGURATION. Inputs (Q) are from Q-SYS, outputs A–D (E–H not shown) represent
the amplifier channels and their configuration.
2. Text indicating how many channels, and the output configuration. For possible
configurations refer to the Q-SYS help for the amplifiercomponents.
3. Status of the amplifier and Q-SYS design indicating the design and amp are in sync.
Routable MIC/LINE Inputs
This screen is not available on the CXD-Qn model amplifiers.
Figure 16
not shown) which displays the status of the physical MIC/LINE INPUTS for the Q models.
1. Input channels are identified numerically, 1–4 (and 5–8 not shown)
2. Input Level – is the Peak Input Level (dBFS) and is the same as displayed in the Q-SYS Mic/
Line Input component.
3. Muted – when illuminated indicates that the Input is muted for the associated channel. This
is controlled by the Mute button on the Q-SYS Designer Mic/Line Input component. Input
channels cannot be muted from the amplifierinterface.
4. Clip – indicators illuminate when the input to the Mic/Line Input component is too high. Adjust
the Preamp Gain on the Mic/Line Input component in Q-SYS Designer.
5. P12 – phantom power (+12V) is available for microphones (condenser) requiring power. You
can turn the phantom power on/off in the Mic/Line Input component in Q-SYS Designer.
is a graphic representations of the amplifier's output CHANNEL
1
2
3
shows the Routable MIC/LINE INPUTS screen for channels 1–4, (channels 5–8
CHANNEL CONFIGURATION
Q A
Channel Configuration Locked to Design
1
2
3
4
Q B
4 Channels: A B C D
— Figure 15 —
ROUTABLE MIC/LINE INPUTS
INPUT LEVELMUTEDCLIPP12
dB
dB
dB
dB
— Figure 16 —
Q C
Q D
Status Screen
Refer to
1. DEVICE – the hostname (network name) of the amplifier. A default name is
2. DESIGN – the name of the Q-SYS design currently running on the amplifier. The
3. STATUS – displays the current status of the amplifier both in text and color. The
4. FIRMWARE – the Q-SYS Designer firmware version installed on the amplifier.
To Update the Amplifier Firmware:
A-TD-001522-01
Figure 17
given at the factory, similar to the example. You may change the name in the
Q-SYS onfigurator.
amplifier must be contained in a running design tooperate.
following is a list of possible status colors, and some example conditions.
• OK – green – audio is good, hardware is good.
• Compromised – orange – audio is good but a redundancy mechanism is active (one
LAN down but the other is still up) or a non-fatal hardware problem exists (fan speed, high temperature, low AC voltage, output load, amplifier is in Protect
mode, etc.)
• Fault – red – audio is not passing, or hardware is malfunctioning or mis-configured (amplifier power off, audio streams broken, amplifier fault,
loudspeaker short circuit, etc.)
• Initializing – blue – In the process of initialization, and design start. Audio is not passed.
NOTE:The CXD-Q 8-channel amplifiers require Version 6.1 or later of Q-SYS Designer.
a. Install the version of Q-SYS Designer you want to use on your PC.
b. The amplifier must be connected to Q-LAN and turned on.
c. Open the Q-SYS design containing the amplifier in the Designer version you just installed.
d. Select "Save to Core and Run" from the File menu.
e. The amplifier and any other Q-SYS peripherals in the design are automatically updated.
STATUS
DEVICE:CXDQ8CH-1234
DESIGN:My Design Filename
STATUS:OK
FIRMWARE:6.1.00
— Figure 17 —
10
Page 11
LAN A / LAN B Screen
HEALTH
4
5
231
6
Refer to
1. IP ADDRESS – a default address is assigned in the factory. You can change this
2. NETMASK – must be the same as the Core's Netmask.
3. GATEWAY – must be the same as the Core's Gateway.
4. LAN B is not required. When connected, the same type of information as LAN A is displayed.
Figure 18
and the other parameters in Q-SYS Configurator. LAN A is required, and cannot be
turned off.
Health Screen
Refer to
1. FAN RPM – varies depending on the temperature.
2. PSU TEMP – varies depending on operating conditions. PSU Temp is monitored
3. AC VOLTAGE – AC Mains voltage
4. AC CURRENT – AC mains current drawn by the amplifier.
5. Voltage Rails
Figure 19
and can automatically put the amp into limiting or shutdown if safe operating
temperatures are exceeded.
• V RAIL 1 = +147VDC +/- 5V typical
• V RAIL 2 = -147VDC +/- 5V typical
LAN A (AUTO)
1
2
3
4
IP ADDRESS:
NETMASK:
GATEWAY:
LAN B (AUTO, NO LINK)
IP ADDRESS:
NETMASK:
GATEWAY:
192.168.xxx.xxx
255.255.0.0
— Figure 18 —
1
2
3
4
5
FAN RPM:
PSU TEMP:35.3°C
AC VOLTAGE:115V
AC CURRENT:1.61A
V RAIL 1:145V
V RAIL 2:-149V
1109
— Figure 19 —
OUTPUT GAINS Screen
Refer to
The Output Gain screens provides a quick overview of all outputs. In addition, when this
screen is displayed, you can make GAIN adjustments on the amplifier's front panel. There is
one screen for channels A–D and one for channels E–H.
Use the NEXT or PREV buttons to access these screens or, press one or more of the SEL
buttons to access the screen.
1. The highlighted background indicates that the Channel is selected by the SEL button.
2. Channel – the channels display according to the configuration of the amplifier.
3. Output Gain – the output gain can be controlled in two places: the GAIN knob on
4. Q-LAN Input Level – the level of the audio signal applied to the Output component in the Q-SYS design. The CXD-Q Output component is
5. VOLTS – the voltage applied to that output.
6. Output B is combined with Output A – (AB or A+B), the slot for Output B is blank.
To Make Gain Adjustments:
Figure 20
the amplifier front panel and with the Gain control in the amplifier's Output component
in the Q-SYS design.
the connection to the output section of the amplifier.
a. Use the SEL button to select one or more channels. You can select any or all channels.
b. Use the GAIN knob to make adjustments on the output gain of the selected channels.
AB
OUTPUT GAINS
-45.0 dB
-45.0 dB
C
-45.0 dB
D
Q-LAN:-8.08 dB
VOLTS:101 V
Q-LAN:
VOLTS:
Q-LAN:
VOLTS:
-100.0 dB
.014 V
-100 dB
.014 V
— Figure 20 —
NOTE:If the gains were the same when you select multiple channels the gains remain equal as you adjust them. If the gains are
different, they keep their relative separation until one reaches a limit. At this point the other channel(s) continue to change until they
reach the limit.
NOTE:If you press one or more of the SEL buttons, and do not make any GAIN adjustments, this screen remains visible for a short
time then returns to the previous screen.
A-TD-001522-01
11
Page 12
Output Screens
2345
6
Each group of outputs has a dedicated screen.
1. Output channel identifiers A – D and E – H (not shown).
2. DAC – when illuminated, this indicates that the signal to the D to A Converter is
larger than can be reproduced and a limiter has been engaged to prevent clipping.
3. PROTECT – when illuminated, this indicates that the amplifier is in Protect Mode.
Usually due to the power supply going above its thermal threshold.
4. LIMIT – when illuminated, this indicates the amplifier limiter is active. There are five
conditions that could cause the LIMIT condition:
• Power
• Current
• Voltage
• Temperature
• Loudspeaker Protection is active.
5. SHORT – when illuminated, this indicates the output is shorted. A short can be triggered by either of the following:
a. Output impedance is below ¼ Ohm for more than 1 second.
b. Output voltage is less than 50% of what the DSP was expecting for more than 1 second.
6. Displays the temperature, in Centigrade, of the associated channel.
Figure 21
is an example of OutputsA–D.
DAC PROTECTLIMITSHORT43.05ºC
A
DAC PROTECTSHORT42.16ºC
1
B
DAC PROTECTSHORT43.06ºC
C
DAC PROTECTSHORT41.05ºC
D
— Figure 21 —
OUTPUT
LIMIT
LIMIT
LIMIT
A-TD-001522-01
12
Page 13
GPIO
10 kΩ
There are 16 General Purpose Input Output pins for use in various applications.
rear of the amplifier. — Table 1 shows the connector pin-out. Figure 23 gives some simple GPIO applications.
— Table 1 —
Connector PinGPIO # and
Specifications
Function
13.3 V100 mA max (power cycle to reset current limiting)
2GPIO 15mA in/out, 3.3V max, 127Ω resistor in series
3GPIO 25mA in/out, 3.3V max, 127Ω resistor in series
4GNDGround
5GPIO 35mA in/out, 3.3V max, 127Ω resistor in series
6GPIO 45mA in/out, 3.3V max, 127Ω resistor in series
7GNDGround
8GPIO 518mA in/out max, 3.3V max, 127Ω resistor in series
9RELAY NO
10RELAY COM
11RELAY NC
12GNDGround
13GPIO 618mA in/out max, 3.3V max, 127Ω resistor in series
14GPIO 718mA in/out max, 3.3V max, 127Ω resistor in series
15GNDGround
16GPIO 818mA in/out max, 3.3V max, 127Ω resistor in series
1 Nominal switching capacity is 30 VDC at 2 A for a total of 60 W maximum. The maximum
voltage is 220 VDC if the current is limited to observe the maximum power rating (60 W).
1
1
1
Relay Normally Open
Relay Common
Relay Normally Closed
Figure 22 shows the pin configuration for the connector on the
1
2
3
4
5
6
7
8
— Figure 22 —
9
10
11
12
13
14
15
16
Examples
Button or Contact ClosurePotentiometerQ-SYS-Powered LED
GPIO
Ground
+3.3 V
GPIO
Analog In
Ground
— Figure 23 —
GPIO 5-8
Ground
Works for LEDs up to 18 mA.
Current is limited in the GPIO
circuit by a 127Ω resister in series.
A-TD-001522-01
13
Page 14
Specifications
CXD8.4Q / CXD8.4QnCXD8.8Q / CXD8.8Qn
Channel Configuration
Max Power
1
Continuous
70 V500 W300 W850 W600 W
100 V500 W300 W850 W600 W
8 Independent Channels
A, B, C, D, E, F, G, H
8Ω500 W300 W850 W600 W
4Ω500 W300 W1000 W600 W
2Ω500 W300 W600 W300 W
2 Channels Combined in BTL Bridge
A+B or C+D or E+F or G+H
Doubles Voltage
2 Channels Combined in Parallel
AB or CD or EF or GH
Doubles Current
3CH Combined in Parallel
ABC or EFG
Triples Current
4CH Combined in Bridged/Parallel
AB+CD
Doubles Current and Voltage
4CH Combined in Parallel
ABCD or EFGH
Quadruples Current
8Ω1000 W
4ΩNR
3
4
2ΩNR 4 NR
8Ω1000 W600 W1100 W1100 W
4Ω1000 W
2Ω1000 W
3
3
8Ω1000 W900 W1100 W1100 W
4Ω1500 W900 W1800 W1800 W
2Ω1500 W900 W2800 W1800 W
8Ω2000 W
4Ω2000 W
2ΩNR
3
3
4
8Ω1200 W1200 W1200 W1200 W
4Ω2000 W1200 W2200 W2200 W
2Ω2000 W
3
600 W
600 W
600 W
1200 W
1200 W
1200 W
CXD8.4Q / CXD8.4QnCXD8.8Q / CXD8.8Qn
Typical distortion
8Ω
4Ω
Maximum distortion
4Ω - 8Ω1.0%1.0%
Frequency response (8Ω)20 Hz – 20 kHz +/- 0.3 dB 20 Hz – 20 kHz +/- 0.3 dB
Noise
Unweighted output muted
Weighted output muted
Gain (1.2V setting)35.4 dB38.4 dB
Damping factor>100>100
Input impedance>8k balanced and >4k unbalanced>8k balanced and >4k unbalanced
Input Sensitivity
Continuously variable:
Controls and indicators (front)Power • Channel MUTE Buttons • Channel SELECT Buttons • Channel Input Signal and CLIP LED Indicators •
Channel Output and LIMIT LED Meters • NEXT, PREV, ID Buttons • Control Knob • Reset Button
Controls and indicators (rear)AC Power Disconnect (IEC Power cord and/or AC Power switch)
Input connectors3-pin Phoenix
Output connectors8-pin Phoenix Speaker
Amplifier and load protectionShort circuit • open circuit • thermal • RF protection • On/Off muting • DC fault shutdown • active inrush limiting
AC power inputUniversal input power supply with active power factor correction 100 - 240 VAC, 50 - 60 Hz
0.02 – 0.05%
0.04 – 0.1%
>101 dB
>104 dB
Vrms
1.23mV to 17.35V
dBu
-56 to 27
dBv
-58.2 to 24.8
NR
NR
2
3
4
4
3
3
3
3
4
3
Max Power
2000 W
1800 W
2000 W
3600 W
4500 W
4000 W
1
3
Continuous
1200 W
NR 4 NR
NR 4 NR
NR
3
3
3
3
4
3
1200 W
600 W
2400 W
2400 W
NR
2400 W
4
4
3
4
0.02 – 0.05%
0.04 – 0.1%
>101 dB
>104 dB
Vrms
1.23mV to 17.35V
dBu
-56 to 27
dBv
-58.2 to 24.8
2
3
3
3
3
3
A-TD-001522-01
14
Page 15
CXD8.4Q / CXD8.4QnCXD8.8Q / CXD8.8Qn
Weight, net / shipping25 lb (11.3 kg) / 29 lb (13.2 kg)26 lb (11.8 kg) / 30 lb (13.6 kg)
Dimensions (HWD)3.5” x 19” x 16” (89mm x 482mm x 406mm)
Agency approvalsUL • CE • RoHS/WEEE compliant • FCC Class B (conducted and radiated emissions)
1 Max Power – 20 ms 1 kHz sine burst, all channels driven
2 Continuous Power – EIA 1 kHz 1% THD, all channels driven
3 BOLD = Optimal configuration for the load and channel count
4 NR = Not Recommended due to excessive current draw
Connector Plug, 8-pin) • Euro-style Connector Plug, 3.5 mm, 16-pin
Heat Loss and Current-Draw Charts
Heat losses are the thermal emissions from an amplifier while it is operating. It comes from dissipated waste power—i.e., real AC power in minus
audio power out. Measurements are provided for various loads at idle, 1/8 of average full power, 1/3 of average full power, and full power, with all
channels driven simultaneously. For typical usage, use the idle and 1/8 power figures. This data is measured from representative samples; due
to production tolerances, actual heat emissions may vary slightly from one unit to another. Bridged mono into 8 ohms is equivalent to 4 ohms per
channel; into 4ohms is equivalent to 2 ohms per channel.
Idle
Thermal loss at idle or with very low signal level.
1/8 Power
Thermal loss at 1/8 of full power is measured with a 1 kHz sine wave signal. It approximates operating with music or voice with light clipping and
represents the amplifier's typical "clean" maximum level, without audible clipping. Use these figures for typical maximum level operation.
1/3 Power
Thermal loss at 1/3 of full power is measured with pink noise. It approximates operating with music or voice with very heavy clipping and a very
compressed dynamic range.
Full Power
Thermal loss at full power is measured with a 1 kHz sine wave. However, it does not represent any real-world operating condition.
Current Draw
The amount of AC current an amplifier demands while it is operating. Measurements are provided for various loads at idle, 1/8 of average full
power, 1/3 of average full power, and full power, with all channels driven simultaneously. The data shown in the following tables is listed for
100VAC, 120VAC and 230VAC operation. For typical usage, use the idle and 1/8 power data.
Voice: +1.714.957.7100 or toll free (U.S. only) 1.800.854.4079
FAX: +1.714.754.6174
E-mail: info@qsc.com
Q-SYS™ Customer Support
Application Engineering and Technical Services
Monday - Friday 7 AM to 5 PM PST (Excludes Holidays)
Tel. 1.800.772.2834 (U.S. only)
Tel. +1.714.957.7150
*Q-SYS 24/7 Support is for Emergency assistance with Q-SYS systems
only. 24/7 support guarantees a call back within 30 min after a
message is left. Please include, Name, Company, Call Back Number
and description of the Q-SYS emergency for prompt call back. If calling
during business hours please use the standard support numbers above.