QSC CX-6-T Brochure

CX6T
FEATURES
Toroidal Output Transformers— Provide Full Electrical Isolation and Meet Worldwide Safety Agency Approval
Automatic T wo-Speed, High Efficiency Fan Cooling—For Quiet Normal Operation with Maximum Cooling on Demand
Rear-to-Front Air Flow—Keeps Equipment Racks Cool
Front Panel Status LED’s—Indicate Clip, Protect, Power and Signal Presence
Rear Panel Detented Gain Controls— For Security and Resetability
Open Input Architecture™—Flexible Input Options
Detachable Euro-Style Barrier Strip Input—Easy and Economical Connections
he CX6T amplifier is ideal for use in any permanently installed sound system. Designed to meet the spe­cialized needs of high power , high quality audio sys­tems, the CX6T offers the features requested most by contractors and installers from around the world. The CX6T resides in a rugged three rack-space steel chassis approximately 17.9 inches deep. With high quality internal isolation transformers, the CX6T fea­tures built-in capability for driving 25, 70 or 100 volt distributed sound systems as well as direct output voice coil loads. Versatile design allows a 25, 70 or
LOAD OUTPUT POWER (Direct Outputs) OUTPUT POWER (Isolated Outputs)
45Hz-20kHz, 0.1% THD 1kHz, 1% THD 1 kHz, 0.1% THD
Stereo (W/Ch)
8 200 watts 220 watts 4 300 watts 350 watts 2 450 watts*
25 volts 200 watts 70 volts 250 watts
100 volts 250 watts
Mono-Bridged
16 400 watts 440 watts
8 600 watts 700 watts 4 900 watts*
50 volts 400 watts 140 volts 500 watts 200 volts 500 watts
100 volt connection on one channel and a direct connection on the other channel. For maximum flex­ibility, you can even drive a distributed line and a low impedance load on the same channel at the same time! The CX6T features a built-in 45 Hz sub­sonic filter that reduces saturation of speaker trans­formers caused by excessively low frequencies. High output power, versatile loading options, high ther­mal capacity and rugged reliability make the CX amplifiers ideal for any high quality sound system installation.
Stereo, Bridge, or Parallel Operating Modes—Switch Selectable
Double Thickness Rack Ears—For Extra Strength
Covered Barrier Strip Output Connections—Meets Safety Agency Requirements
Simple Barrier Strip Connection Determines Output Mode—25 V , 70 V , 100 V and Direct Outputs Available Simultaneously
Built-in 45 Hz Subsonic Filter— Prevents Speaker Transformer Saturation With Minimal Effect on Program Material
1675 MacArthur Boulevard Costa Mesa, California 92626-1468 USA Phone: 714/754-6175 Fax: 714/754-6174
*typical
POWER OUTPUT
Direct output, watts per channel, both channels driven
8, 45 Hz-20 kHz, 0.1% THD 200 8, 1 kHz, 1% THD 220 4, 45 Hz-20 kHz, 0.1% THD 300 4, 1 kHz, 1% THD 350 2, 1 kHz, 1% THD* 450
Isolated outputs, watts per channel, both channels driven
70V or 100V, 1 kHz, 0.1% THD 250 25V, 1 kHz, 0.1% THD 200
Direct Outputs, bridged mono
8, 45 Hz-20 kHz, 0.1% THD 600 4, 1 kHz, 1% THD* 900
Isolated outputs, bridged mono
50V, 1 kHz, 0.1% THD 400 140V, 1 kHz, 0.1% THD 500 200V, 1 kHz, 0.1% THD 500
DISTORTION SMPTE-IM, less than 0.05%, direct outputs FREQUENCY RESPONSE
Direct outputs: -3 dB @ 45 Hz*, -0.2 dB @ 20 kHz Isolated outputs: 45 Hz*-16 kHz, +0, -3 dB
* Low frequency response is limited by 18 dB/octave 45-Hz high-pass filter.
DAMPING FACTOR 200 (@ direct outputs) OUTPUT REGULATION 100V–1.0 dB; 70V–1.1 dB; 25V–2.0 dB NOISE 100 dB below rated output (20 Hz to 20 kHz) VOLTAGE GAIN
@ direct outputs 40x (32 dB)
INPUT SENSITIVITY, VRMS
for rated power, 8 1.02
INPUT IMPEDANCE 10K unbalanced, 20K balanced CONTROLS
CX6T Specifications
Front: AC Switch Rear: Parallel/Stereo/Bridge Switch, Ch.1 and Ch. 2 Attenuator Knobs (11 detents: 0, -2, -4, -6, -8, -10, -12, -14, -18, -24, off)
FRONT PANEL/INDICATORS (per channel)
PROTECT: Red LED CLIP: Red LED SIGNAL: Yellow LED POWER: Green LED
REAR PANEL/CONNECTORS (each channel)
Input: Euro-style detachable header Output: Covered barrier strips
COOLING 2-speed fan, with back-to-front air flow AMPLIFIER PROTECTION
Output Averaging™ short circuit protection, open circuit, ultrasonic, RF, thermal muting Stable into reactive or mismatched loads
LOAD PROTECTION Turn-on/turn-off muting, DC-fault load grounding relay with internal fault fuses OUTPUT CIRCUIT TYPE Class AB complementary linear stage POWER REQUIREMENTS: 100, 120, 220-240 VAC, 50/60 Hz
POWER CONSUMPTION
Normal operation: 1/8 power @ 4 per channel Worst case continuous program: 1/3 power @ 2 per channel Maximum: full power @ 2 per channel Multiply current by 0.5 for 220-240 VAC operation
Channel Load AC Current, Full Power AC Current, 1/3 Power AC Current, 1/8 Power AC Current, Idle
8 + 8 7.7 A 4.9 A 3.3 A 0.6 A 4 + 4 12.5 A 7.4 A 4.8 A 0.6 A 2 + 2 18.8 A 11.0 A 7.2 A 0.6 A
25V, 70V, 100V 11.2 A 6.7 A 4.5 A 0.6 A
FPO/BACK
ARCHITECT’S AND ENGINEER’S SPECIFICATIONS
The amplifier shall contain all solid-state circuitry, using complementary silicon output devices in a Class AB output circuit. The amplifier shall operate from 50-60 Hz AC power, with internal taps for selecting voltages 100,120, or 220-240 VAC. The amplifier shall operate from a normal house­hold AC outlet, drawing less than 580 VA when driven with random pro­gram material at 1/8 rated power into four ohm loads. The amplifier shall be supplied with a single molded AC cord having an appropriate AC plug for the intended operating voltage.
The amplifier shall employ forced-air cooling with a two speed fan for minimum acoustic noise. Air flow shall be from rear to front to avoid tem­perature rise inside the rack. Rack mounting shall be possible without clearance necessary between amplifiers for ventilation. The amplifier shall be capable of continuous operation at 1/8 power, into four -ohm loads, for ambient temperatures up to 104 F (40 C).
The amplifier shall contain two independent channels, with separate AC transformer secondaries, power supplies, and protection systems. All pro­tection systems shall be self resetting upon removal of fault, and the re­maining channel shall continue to operate. Each channel shall have inde­pendent protective circuitry against open circuit, short circuit, or mis­matched loads. Each channel shall monitor temperature of its heat sink and power transformer, and shall trigger fan speed boost, and if neces­sary, signal muting to prevent excessive temperature rise. Each channel shall have on-off muting, acting for three seconds after turn-on, and within 1/4 second after turn-off or loss of AC power. Each channel shall have DC fault protection for the load, consisting of a load-grounding relay with fault fusing to interrupt power. Fault fuses shall be adequately large to prevent nuisance blowing at any output power the amplifier is capable of delivering.
Each channel shall have the following controls and displays: A rear panel Gain control and Bridge/Stereo/Parallel mode switch, front panel displays consist of a green LED power-on indicator; one yellow LED signal indica­tor, triggering at -30 dB; a red LED showing true amplifier clipping; and a red LED which indicates muting when illuminated. The output connectors for each channel shall be shrouded barrier strip connectors. The input connector shall be mounted on a removable panel to permit upgrades. The standard input panel shall provide detachable Euro-style header con­nections for each channel. Inputs shall be electronically balanced, with a minimum impedance of 10 kilohms per side, and a common mode rejec­tion of at least 50 dB from 20 Hz to 20 kHz. The standard input panel shall contain switches for mono-bridging and parallel inputs, and solder pat­terns for input isolation transformers, gain reduction resistors, and first­order high and low pass filters .
The input panel shall have enough space behind it to contain a circuit board measuring up to 5.9" wide by 4.1 “ deep. The multi-pin connector to the amplifier circuitry shall supply positive and negative DC supply cur­rents, and for each channel, balanced input signals, output signal, and clip/protect signal. Optional XLR and 1/4” RTS input connectors may be installed in place of a standard blank panel, mounted above the standard input panel.
Internally-mounted toroidal output transformers shall provide electrically isolated output taps for 25, 70, and 100 volt distributed lines. The direct amplifier output shall also be available to drive voice coil loads. The use of voice coil and distributed line operation is independent on each chan­nel. It is possible to use both the direct and isolated outputs simulta­neously on a single channel, as long as the total power rating of the am­plifier is not exceeded. A built-in 45 Hz, third-order subsonic filter shall be provided to reduce saturation of speaker transformers, due to exces­sive low frequency program material. The filter is non-defeatable and affects all outputs.
Each channel shall be capable of meeting the following performance cri­teria with both channels driven: Sine-wave output power of 200 watts into eight ohms, and 300 watts into four ohms, 45 Hz to 20 kHz, with less than O.1% THD. Frequency response at 3 dB below rated power shall be ­3 dB at 45 Hz and -0.2 dB at 20 kHz. The voltage gain shall be 40, equiva­lent to 32 dB, and the input sensitivity shall be 1.02 Vrms. The signal to noise ratio over the range of 20 Hz to 20 kHz shall exceed 100 dB. IHF damping factor shall exceed 200 for the direct outputs. Output regula­tion, of the isolated outputs, shall not exceed 1.0 dB at 100 volts, 1.1 dB at 70 volts and 2.0 dB at 25 volts.
The amplifier chassis shall occupy three rack spaces, with provision for securing the rear corners. Depth from mounting surface to tips of rear supports shall be 17.9" (45.5 cm).
Weight shall not exceed 55 Ibs. (25 kg). The amplifier shall be the QSC Audio Products Model CX6T.
DIMENSIONS
Faceplate Width Standard 19" (48.3 cm) Rack Mounting Chassis Depth 17.9" (45.5 cm) deep (to rear support ears) Faceplate Height 5.25" (13.3 cm)
WEIGHT Shipping–62 lb; 28 kg; Net–55 lb; 25 kg
1675 MacArthur Boulevard • Costa Mesa, California 92626-1468 USA • Phone: 714/754-6175 Fax: 714/754-6174