ProMariner TruePower Inverter Series Installation Guide

0 (0)
ProMariner
On Board
®
Solutions
A ProMariner Company
ProMariner
®
On Board
Solutions
A ProMariner Company
Heavy Duty Marine / Industrial Grade
Here are just a few:
ProMite Series - Standard Edition Waterproof Marine Battery Chargers
ProSport Series - Recreational Sport Fishing & Boating Waterproof Marine Battery Chargers
ProTournament Series - Professional Grade Tournament Waterproof Marine Battery Chargers
Advanced 4 Step Dry Mount Marine Battery Chargers
Battery Maintainers
AC Plug Holders
Battery Isolators
ProSport Cup Holder Inverters
Pro Inverters
DC to AC Inverters
Advanced Regulators
Corrosion Control Products
Waterproof Marine Binoculars
Marine CCTV Color Camera Equipment
Gold Plated Fuses and Holders
A Complete Selection of Panel Meters and Shunts
A Complete Line of Hand Held Test Meters
Online Technical Support and Service Support
TruePower Inverter Series
600 - 1200 Watt Mid Power Models
Owner Manual & Installation Guide
Model Part Number Description
600 Watt 05060 12 VDC Input / 600 Watt 110 VAC Output Inverter 800 Watt 05080 12 VDC Input / 800 Watt 110 VAC Output Inverter 1000 Watt 05100 12 VDC Input / 1000 Watt 110 VAC Output Inverter 1200 Watt 05120 12 VDC Input / 12000 Watt 110 VAC Output Inverter
Visit frequently, we are always adding new products for your boating enjoyment!
Factory Service TEL: 1-800-824-0524 www.promariner.com www.onboardsolutions.biz 8:30 - 5:00 Eastern Time 200 International Drive, Suite 195 Portsmouth, NH 03801
specifications subject to change without notice
02/05
Your Satisfaction is Important to us. Do Not return this Product to the Retailer or Dealer for any service or warranty requirements. Please call our Customer Care Department line at 1-800-824-0524 from 8 am to 5 pm (Eastern Time) for warranty, service or installation assistance you may need. Thank you.
IMPORTANT SAFETY NOTICE - SAVE THESE INSTRUCTIONS
Please save and read all safety, operating and installation instructions before installing or applying DC power to your TruePower Inverter.
Notes
Table Of Contents
Safety and Precautions... pages 1-2
Installation Preparations... pages 2-3
Overview... pages 3-4
Features... page 5
Installation Guidelines... pages 5-9
Testing Your Inverter... pages 9-10
Operation... pages 11-12
Trouble Shooting... pages 13-16
Specification... page 17
Customer Service & Warranty... page 18
Introduction
Thank you from all of us at On Board Solutions, A ProMariner Company. Congratulations on your recent purchase of a TruePower Inverter!
Leading the Marine industry in Power Conversion for over 30 years, ProMariner’s On Board Solutions division has designed a complete line of Power Inverters ranging from 200 to 3,000 watts specifically for Marine / Industrial use. TruePower Inverters will convert your OnBoard 12Vdc Battery power to 110Vac Household Power to run TV’s, Laptops, Gaming Systems, power tools, hairdryers, coffee makers, blender’s, large appliances and more.
Please save and read this manual carefully and fully understand the safety instructions before installing your new TruePower Inverter.
Safety & Precautions
Customer Service & Warranty
1
General Safety Instructions
Before installing and using your new inverter, read all appropriate sections of this guide and any cautionary markings on the inverter, batteries and on your appliances.
1. CAUTION: Do not operate the inverter if the carton or unit has significant damage from being dropped or crushed, received a direct hit of force or is otherwise damaged.
2. CAUTION: Do not dismantle the inverter. Call the factory directly when service or repair is required. Incorrect assembly may result in risk of electrical shock or fire.
3. CAUTION: To reduce the risk of electrical shock, disconnect both AC and DC power from the inverter prior to any maintenance or cleaning.
4. CAUTION: Protect the inverter from rain, snow water and spray.
5. CAUTION: Internal inverter components remain charged after power is disconnected.
6. CAUTION: As a precaution - Keep Children away from the inverter and its components!
The same potentially hazardous or lethal AC power that is found in a normal household 110AC power outlet can be found in the TruePower inverter.
7. CAUTION: Under no circumstance should the user connect live AC (household) power to the inverter’s AC receptacles. The inverter will become damaged even if it is switched off. This unit can only take 12V DC battery power and invert it to 110V AC household power. This unit is not a battery charger!
8. CAUTION: For an ABYC E-11 compliant installation, this Inverter must be installed with an inline fuse in the positive (+) cable on the DC side of the inverter (between the battery and the inverter) at a distance of seven inches from the battery connection (Please see Specifications Table in this Manual for correct sizing).
Personal Safety Precautions
1. Someone should be within the range of your voice or close enough to come to your aid when installing power inverters or working near lead acid batteries.
18
Customer Service & Warranty
We are committed to customer satisfaction and value your business. If at any time during the warranty period you experience a problem with your new TruePower Inverter simply call us at 1-800-824-0524 during standard business hours (8:30 AM – 5 PM Eastern Time) for technical support.
TRUEPOWER
TWO YEAR LIMITED FACTORY WARRANTY
Each product is guaranteed against defects in material and workmanship to the original consumer in normal use for two full years from the date of purchase. On Board Solutions and Professional Mariner, LLC at its discretion will repair or replace free of charge any defects in material or workmanship. The following conditions apply:
• Warranty is calculated from date of manufacture if not registered within two weeks of sale.
• Warranty void if damage occurs due to negligent repairs.
• Customer is responsible for returning the product to On Board Solutions and Professional Mariner, LLC. inbound shipping costs must be prepaid.
• This warranty does not cover blemishes due to normal wear and tear or damages caused by accidents, abuse alterations or misuse.
Purchase or other acceptance of the product shall be on the condition and agreement that On Board Solutions and Professional Mariner SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND. (Some states do not allow the exclusion or limitation of consequential damages, so the above limitations may not apply to you.) This warranty is made in lieu of all other obligations or liabilities on the part of Onboard Solutions and Professional Mariner. Additionally, On Board Solutions and Professional Mariner neither assumes nor authorizes any person for any obligation or liability in connection with the sale of this product.
To make a claim under warranty, call Factory Service at 1-800-824-0524. Follow the company’s return policy, which will be provided by the company. On Board Solutions and Professional Mariner will make its best effort to repair or replace the product, if found to be defective within the terms of the warranty, within 30 days after return of the product to the company. On Board Solutions and Professional Mariner will ship the repaired or replaced product back to the purchaser.
The GFCI is covered by a 90 day warranty limitation, as the life of a GFCI in a harsh, humid, outdoor marine environment cannot be guaranteed. The GFCI is a standard off the shelf serviceable / replaceable component in the TruePower Inverter Series. Please contact Customer Service for additional assistance.
This warranty provides to you specific legal rights and you may also have other rights, which vary from state to state. This warranty is in lieu of all other, expressed or implied.
2. Wear complete eye protection and protective clothing. Avoid touching eyes while working on or with batteries. Have plenty of soap and water nearby in case of battery acid comes in contact with skin, clothing or eyes.
3. If battery acid comes in contact with skin or clothing, wash immediately with soap and water. If acid enters the eye (s) flood eye (s) with running water for at least 10 minutes and get medical attention immediately.
4. Never smoke or allow a spark or a flame in the vicinity of a battery or engine.
4
Specifications
Safety & Precautions / Installation Preparation
17
Specifications
TruePower 600W 800W 1000W 1200W
Power (W) 600W 800W 1000W 1200W Continuous Power 600W 800W 1000W 1200W Surge Power 1200W 1600W 2000W 2400W Output Waveform Modified Sine Wave AC Output Voltage 115V +/- 10% AC Output Amps (up to)(continous) 5.5 7.3 9.1 10.9
DC Input Voltage 10V to 15V DC Input Amps (up to) 60A 80A 100A 120A
Efficiency >85% No load Current <0.65A <0.8A <1.0A <1.0A Cooling Fan Yes Short Protection Yes Soft- Start Yes High Voltage Protection Yes
Low Battery Alarm (Bat’ Saver) 11.9VDC Low Battery Shutdown (Bat’ Saver) 11.5VDC Low battery Alarm 10.5VDC +/- .5VDC Low Battery Shutdown 10VDC +/- .5VDC
Reverse Polarity Protection (By Fuse) Yes Operating environment temperature -15 to 50° Celsius or 5 to122° Fahrenheit Internal Fuse 20A * 4pcs 35A * 3pcs 35A * 4pcs 35A * 4pcs Recommended User Supplied 80A 105A 140A 140A
ABYC E-11 Compliant Fuse
2
Personal Safety Precautions Continued
5. Be extra cautious to reduce the risk of dropping a metal tool onto a battery. It may spark or short-circuit the battery or other electrical parts that may cause an explosion.
6. Remove all personal metal items such as rings, bracelets, necklaces, watches and jewelry when working near a battery. A battery can produce a short circuit high enough to weld a ring or any metal, causing serious burns.
7. Never charge or invert power from a frozen battery.
*WARNING: Restrictions on Use- The TruePower inverter shall not be used in connection with life support systems or other medical equipment devices.
Preparing for Installation
Read this entire installation section if you plan a hardwire installation from beginning to end.
WARNING: This devise is not Ignition Protected Avoid serious injury or death from or explosion. Do not install in compartments containing gasoline fueled engines or gasoline tank, or in areas where ignition protected equipment is required.
WARNING: Do not mount the inverter above or below your batteries.
WARNING: Electrical shock and fire hazards On Board Solutions, a ProMariner Company recommends all wiring be done by qualified personnel. Disconnect all AC and DC power sources to prevent accidental shock. Disable and secure all AC and DC disconnect devices and automatic generator starting devices. It is the installer’s responsibility to ensure compliance with all the applicable installation codes and regulations.
ProMariner Part No. for Recommended User Supplied ABYC E-11 Compliant Fuse
Amperage
ANL Ignition Protected Fuses for TruePower Models
Single Position ANL
High Amperage
Fuse Holder
88120 88100 88100 88160 88160
100-425 amps 100 amp 100 amp 160 amp 160 amp
600 Watt 800 Watt 1000 Watt 1200 Watt
WARNING: Installation Precaution The TruePower inverter should be mounted on a flat horizontal surface or a vertical surface with the front panel and label facing the user. In no case should the front or rear endcaps be facing in an upward or downward position. This allows proper ventilation and product safety of the unit as intended by design.
WARNING: Fire Hazard Do not cover or obstruct the ventilation openings. Do not install this equipment in a compartment with limited airflow; Overheating may result.
Loading...
+ 7 hidden pages