Planet ISW-800T-M12 User Manual

1. Package Contents
Thank you for purchasing PLANET Industrial IP67-rated 8-Port 10/100Mbps M12 Ethernet Switch, ISW-800T-M12. In the following sections, the term “Industrial M12 Ethernet Switch” means the ISW-800T-M12.
Open the box of the Industrial M12 Ethernet Switch and carefully unpack it. The box should contain the following items:
Ethernet Switch x 1
1.2m M12 Power Cable x 1
User’s Manual x 1
DIN-rail Kit x 1 Wall Mount Kit x 1
1.2m M12-to-RJ45 UTP Cable x 1
Power LED: Power 1/Power 2 (Green),
LED Indicators
FAULT (Green) 10/100BASE-TX Port (Port-1 to Port-8): LNK/ACT (Green)
10BASE-T: 2-pair UTP Cat.3,4,5 up to 100m (328ft)
Network Cables
100BASE-TX: 2-pair UTP Cat.5, 5e, 6 up to 100m (328ft) EIA/TIA-568 100-ohm STP (100m, max.)
Switch Specications
Switch Processing Scheme
Store-and-Forward
Address Table 2K entries
Flow Control
Back pressure for half duplex IEEE
802.3x Pause Frame for full duplex
Switch Fabric 1.6Gbps
Throughput (packet per second)
Maximum Transmit Unit
1.19Mpps@64Bytes
1536 bytes
3. Hardware Introduction
3.1 Front Panel
The front panel of the Industrial M12 Ethernet Switch consists of Ethernet interfaces and LED indicators.
Front View
1
2
3
4
DC Input: 9-48V
, 0.5A max.
LNK/ACT
LNK/ACT
LNK/ACT
LNK/ACT
V2V2V1
Fault
PWR 2
PWR 1
LNK ACT
V1
IP67 M12
TXRXRX
ISW-800T-M12
5
6
7
8
TX
3.2 M12 DC Power Cable Pinout
The Industrial M12 Ethernet Switch front panel provides one M12 A-coded 5-pin male connector for DC power input; please use the power cable with M12 A-coded 5-pin female connector from Industrial M12 Ethernet Switch package for DC power input. The Industrial M12 Ethernet Switch power input port pinout is shown below:
ISW-800T-M12
2
3
V2
V2
4
INPUT
DC 9V~48V
V1
V1
1
Pinout 1: V1
Pinout 2: V1+
Pinout 3: V2+
Pinout 4: V2
Please follow the steps below for DC power cable installation on Industrial M12 Ethernet Switch.
1. Plug the DC power cord connector to the power input port of
the Industrial M12 Ethernet Switch.
2. Screw the nut on DC power cord female connector to the DC power input male connector of Industrial M12 Ethernet Switch and make sure the connection is tight.
Before DC power cord connection, please check
Note
and assure your local DC power source is stable.
-
-
- 1 -
If any of these pieces are missing or damaged, please contact your dealer immediately; if possible, retain the carton including the original packing material, and use them again to repack the product in case there is a need to return it to us for repair.
2. Product Specications
Model ISW-800T-M12
Hardware Specications
10/100BASE-TX Ports
Power Connector
Enclosure IP67 aluminum
Dimensions (W x D x H)
Weight 976g
Power Requirements
Power Consumption/ Dissipation
Installation DIN-rail kit and wall mount ear
ESD Protection 6KV DC
8 x M12, 4-Pin D-coded female connector
1 x M12, 5-Pin A-coded male connector
103 x 53 x 163mm
9~48V DC, redundant power with reverse polarity protection
4watts/13BTU
Standards Conformance
Standards Compliance
Regulatory Compliance
Stability Testing
Environment
Temperature
Humidity
- 3 -
IEEE 802.3 Ethernet IEEE 802.3u Fast Ethernet IEEE 802.3x Flow Control and Back Pressure
FCC Part 15 Class A, CE
IEC60068-2-32 (Free fall) IEC60068-2-27 (Shock) IEC60068-2-6 (Vibration)
Operating: -40~75 degrees C Storage: -40~75 degrees C
Operating: 5~95% (non-condensing) Storage: 5~95% (non-condensing)
Figure 3-1: ISW-800T-M12 Front View
- 5 -
System LEDs
LED Color Function
PWR 1 Green Lit: To indicate power 1 has power.
PWR 2 Green Lit: To indicate power 2 has power.
Fault Green
Lit: To indicate either power 1 or power 2 has no power.
10/100BASE-TX M12 Interface LEDs
LED Color Function
Lit: To indicate the Switch is successfully connecting to the network at 10/100Mbps.
LNK/ ACT
Green
Blink: To indicate that the Switch is actively sending or receiving data over that port.
O: To indicate the Switch is not
connecting to the network at 10/100Mbps.
- 7 -
3.3 10/100BASE-TX Ports with M12 Interface
Cable Pinout
The Industrial M12 Ethernet Switch front panel provides eight RJ45 10/100BASE-TX ports and M12 interfaces. These ports are designed for Ethernet equipment connection. The Industrial M12 Ethernet Switch 10/100Mbps M12 input interface pinout is shown below:
ISW-800T-M12
RX
TX
3
Pinout 1: TX+
Pinout 2: RX+
Pinout 3: TX
Pinout 4: RX -
Pin
1 2 3 6
-
Signal MDI MDI-X TX+
RX+
TX
RX
-
RX+
TX+
RX
TX
-
-
-
142
TX
RX
Pinouts for the RJ45 (8-Pin) Port
RJ45 (8-Pin)
1 8
Please follow the steps below for the 10/100Mbps M12 cable installation of Industrial M12 Ethernet Switch.
1. Plug the 10/100Mbps M12 cable male connector to the Ethernet female connector input port of the Industrial M12 Ethernet Switch.
2. Screw the nut on 10/100Mbps M12 cable male connector to the Ethernet input female connector of Industrial M12 Ethernet Switch and make sure the connection is tight.
- 2 -
- 4 -
- 6 -
- 8 -
As each Ethernet port of Industrial M12 Ethernet
Taiwan
July 22, 2020
Country
Date
Legal Signature
Switch is running in auto negotiation mode, make sure the opposite Ethernet devices Ethernet
Note
ports are also running in auto negotiation mode, otherwise, the Ethernet performance will be poor.
4. Installation
This section guides you to installing the Industrial M12 Ethernet Switch on the DIN rail and wall. Please read this chapter completely before continuing.
5. Three-View Diagram
54.6
DC Input:
9-48V
, 0.5A max.
PWR 1
IP67 M12
ISW-800T-M12
104
3
4
V2
V2
LNK/ACT
LNK/ACT
PWR 2
Fault
V1
V1
RX
TX
RX
TX
7
8
52
123
1
2
LNK/ACT
LNK/ACT
6
44
ACT
LNK
5
53 9
In the installation steps below, this manual uses PLANET IGS-801 8-port Industrial Gigabit Switch
Note
as an example. The steps for PLANET Industrial M12 Ethernet Switch are similar.
- 9 -
4.1 DIN-rail Mounting Installation
1
2
4.2 Wall-mount Plate Mounting
48.8
60
40
163
100
188 204
103
68
6
50
84
100
40
Unit: mm
Figure 5-1: ISW-800TM12 Three-View Diagram
- 11 -
6. Customer Support
Thank you for purchasing PLANET products. You can browse
our online FAQ resource on PLANET web site rst to check if it
could solve your issue. If you need more support information, please contact PLANET support team.
PLANET online FAQs: http://www.planet.com.tw/en/support/faq
Support team mail address: support@planet.com.tw
FCC Warning
This device has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the Instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
WEEE Warning
To avoid the potential eects on the environment and
human health as a result of the presence of hazardous substances in electrical and electronic
equipment, end users of electrical and electronic equipment should understand the meaning of the crossed-out wheeled bin symbol. Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately.
EC Declaration of Conformity
I hereby confirm that the following equipment complies with the requirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility Directive on (2014/30/EU).
Type of Product:
Industrial IP67 Rated 8-Port 10/100Mbps M12 Ethernet Switch
Models:
ISW-800T-M12
Produced by:
Manufacturer’s Name: Planet Technology Corporation
Manufacturer’s Address: 10F., No.96, Minquan Rd., Xindian Dist.,
For the evaluation regarding the EMC, the following standards were applied:
EN 55032 (2015 + AC:2016)
EN 55024 (2010 + A1:2015)
EN 55035 (2017)
Person responsible for making this declaration
Name: Kent Kang
Title: Director
New Taipei City 231, Taiwan, R.O.C.
Caution
You must use the screws supplied with the wall­mounting brackets. Damage caused to the parts by using incorrect screws would invalidate your warranty.
- 10 -
Copyright © PLANET Technology Corp. 2020. Contents are subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.
- 12 - - 13 -
PLANET TECHNOLOGY CORPORATION
10F., No.96, Minquan Rd., Xindian Dist., New Taipei City, Taiwan, R.O.C. Tel:886-2-2219-9518 Fax:886-2-2219-9528
e-mail: sales@planet.com.tw http://www.planet.com.tw
Loading...