Planet ISW-504PT operation manual

1. Package Contents
Thank you for purchasing PLANET 5-Port Industrial Ethernet Switch with 4-Port PoE, ISW-504PT/ISW-514PTF. The interfaces of these models are shown below:
Model Name
ISW-504PT 5 - 4
ISW-514PTF 4 1 4
In the following section, the term “Industrial PoE+ Switch” means the ISW-504PT/ISW-514PTF.
10/100Mbps
RJ45 Ports
2. Hardware Introduction
2.1 Switch Front Panel
P1 P2 Fault
1 2 3 4 5
DIP
ON
OFF
1~4
Extended
挖孔
ONDIP
10/100TX
LNK/ ACT
挖孔
Standard
5
VLAN
Standard
120W
90W
60W
5
30W
PoE Usage
4
3
2
P1 P2 Fault
1 2 3 4 5
挖孔
ONDIP
100FX
挖孔
2.2 LED Indicators
System
LED Color Function
P1 Green Lights: indicates power 1 has power.
P2 Green Lights: indicates power 2 has power.
DIP
ON
OFF
1~4
Extended
Standard
5
VLAN
Standard
120W
90W
60W
5
30W
PoE Usage
4
3
FAULT Red
30W Orange
60W Orange
2
Lights: indicates either power 1 or power 2 has no power.
O: indicates the PoE usage is less than 14W. Blinks: indicates that the PoE usage is around 15W to 29W. Lights: indicates the PoE usage is around/ over 30W.
Blinks: indicates that the PoE usage is around 45W to 59W. Lights: indicates the PoE usage is around/ over 60W.
Per 100FX SFP Slot (Port 5 of ISW-514PTF)
LED Color Function
Lights: indicates the link through that port is
LNK/
ACT
Green
successfully established at 100Mbps. Blinks: indicates that the switch is actively sending or receiving data over that port.
2.3 Switch Upper Panel
The upper panel of the Industrial PoE+ Switch consists of one terminal block connector within two DC power inputs.
Figure 2-3 shows the upper panel of the Industrial PoE+ Switch.
- 1 -
Open the box of the Industrial PoE+ Switch and carefully unpack it. The box should contain the following items:
Industrial PoE+ Switch x 1 User’s Manual x 1
Dust Cap x 4 Wall-mount Kit x 1
1
LNK ACT PoE-in-Use
ISW-504PT
Figure 2-1:
ISW-504PT front panel
ISW-514PTF front panel
1
LNK ACT PoE-in-Use
ISW-514PTF
Figure 2-2:
Fast Ethernet TP Interfaces
10/100BASE-TX copper, RJ45 twisted-pair: Up to 100 meters.
- 3 -
100BASE-FX SFP Slot (ISW-514PTF)
100BASE-FX mini-GBIC slot, SFP (Small Factor Pluggable)
transceiver module: From 2 kilometers (multi-mode ber) to 20/40/60 kilometers (single-mode ber).
DIP Switch
The Industrial PoE+ Switch provides one DIP switch for Standard, VLAN and Extended mode selections. The detailed descriptions are shown in the following table.
DIP Switch
Mode
Standard
VLAN
This mode makes the Industrial PoE+ Switch operate as a general switch and all PoE ports operate at 10/100Mbps auto-negotiation.
This mode makes the Industrial PoE+ Switch operate as a VLAN isolation switch and
1. Port 1 to port 4 will isolate respectively.
2. Port 1 to port 4 can only communicate with port 5.
After adjusting VLAN DIP switch, reboot the Industrial PoE+ Switch
Note
to make the change take effect.
Function
Blinks: indicates that the PoE usage is
90W Orange
around 75W to 89W. Lights: indicate the PoE usage is around/ over 90W.
Blinks: indicates that the PoE usage is
120W Orange
around 100W to 119W. Lights: indicates the PoE usage is at the maximum.
- 5 -
Per 802.3at PoE+ 10/100BASE-TX Interface (Port 1
to Port 4)
LED Color Function
Lights: indicates the link through that port
is successfully established at 10Mbps or LNK/ ACT
Green
100Mbps.
Blinking: indicates that the switch is
actively sending or receiving data over that
port.
Lights: indicates the port is providing DC PoE in-Use
Orange
in-line power.
O: indicates the connected device is not a
PoE powered device (PD).
Per 10/100BASE-TX Interface (Port 5 of ISW-504PT)
LED Color Function
Lights: indicates the link through that port is LNK/ ACT
Green
successfully established at 10/100Mbps.
Blinking: indicates that the switch is actively
sending or receiving data over that port.
1 2 3 4 5 6
Input DC 12~48V
FaultDC1 DC2
Figure 2-3: Industrial PoE+ Switch Upper Panel
- 7 -
Fault max.
load 1A@24V
2.4 Wiring the Power Inputs
The 6-contact terminal block connector on the top panel of Industrial PoE+ Switch is used for two DC redundant power inputs. Please follow the steps below to insert the power wire.
When performing any of the procedures like inserting the wires or tightening the wire-clamp screws, make sure the power is OFF to prevent from getting an electric shock.
1. Insert positive and negative DC power wires into contacts 1 and 2 for POWER 1, or 5 and 6 for POWER 2.
1 2 3 4 5 6
Input DC 12~48V
FaultDC1 DC2
Fault max.
load 1A@24V
If any of these are missing or damaged, please contact your dealer immediately.
- 2 -
Extended
This mode makes the Industrial PoE+ Switch operate on a per-port basis at 10Mbps full duplex operation but can support IEEE 802.3af PoE power output over a distance of up to 250 meters overcoming the 100m limit on Ethernet UTP cable.
- 4 -
- 6 -
- 8 -
2. Tighten the wire-clamp screws for preventing the wires from loosening.
1 2 3 4 5 6 Power 1 Fault Power 2
+ - + -
The wire gauge for the terminal block should be in
Note
Note
the range between 12 and 24 AWG.
1. The DC power input range is 12V ~ 48V DC.
2. When the DC power input range is 12V, the PoE budget is 60W; When the DC power input range is 24V, the PoE budget is 90W; When the DC power input range is 48V, the PoE budget is 120W.
To avoid damage, please use the Industrial PoE+
Switch under its specification.
3. Installation
This section describes the functionalities of the Industrial PoE+ Switch’s components and guides how to install it on the DIN-rail and wall. Basic knowledge of networking is assumed. Please read this chapter completely before continuing.
The installation procedures of the ISW-504PT and ISW-514PTF are the same as they are shown
Note
3.1 DIN-rail Mounting Installation
below.
- 9 -
2.5 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal block connector as the picture shows below. Inserting the wires, the Industrial PoE+ Switch will detect the fault status of the power failure and then forms an open circuit. The following illustration shows an application example for wiring the fault alarm contacts.
1 2 3 4 5 6
The Fault Alarm Contacts are energized (CLOSE) for normal
Fault Alarm Contacts
Insert the wires into the fault alarm contacts
1. The wire gauge for the terminal block should be in the range between 12 and 24 AWG.
Note
2. Alarm relay circuit accepts up to 24V, max. 1A currents.
Fault
operation and will OPEN when failure occurs
- 11 -
3.2 Wall-mount Plate Mounting
3.3 Side Wall-mount Plate Mounting
4. Troubleshooting
This chapter contains information to help you solve issues. If the Industrial PoE+ Switch is not functioning properly, make sure the Industrial PoE+ Switch was set up according to instructions in this manual.
The per port LED is not lit
Solution: Check the cable connection of the Industrial PoE+ Switch.
Per port LED is lit, but the trac is irregular
Solution: Check whether the attached device is not set to dedicated full duplex. Some devices use a physical or software switch to change duplex modes. Auto-negotiation may not recognize this type of full-duplex setting.
Why the Industrial POE+ Switch doesn’t connect to
the network
Solution: Check each port LED on the Industrial PoE+ Switch. Try another port on the Industrial PoE+ Switch. Make sure the
cable is installed properly and the right type. Turn o the
power. After a while, turn on the power again.
I connected a PoE powered device to the Industrial
POE+ Switch, why it could not be powered on
Solution:
1. Please check the cable type of the connection from Indus­trial POE+ Switch (port 1 to port 4) to the other end. The cable should be an 8-wire UTP, Category 5e or above, EIA568 cable within 100 meters. A cable with only 4-wire,
short loop or over 100 meters will aect the power supply.
2. Please check and assure the PoE powered device is fully complied with IEEE 802.3at standard.
5. Customer Support
Thank you for purchasing PLANET products. You can browse
our online FAQ resource at the PLANET Web site rst to
check if it could solve your issue. If you need more support information, please contact PLANET PoE support team.
FAQ: https://www.planet.com.tw/en/support/faq?method=category&c1=3
support: support_switch@planet.com.tw
- 10 -
- 12 - - 13 - - 14 -
Loading...