Planet ISW-501T operation manual

1. Product Introduction
1.1 Package Contents
Check the contents of your package for the following parts:
Industrial Fast Ethernet Switch x 1
User’s Manual x 1
DIN Rail Kit x 1
Wall-mount Kit x 1
1.2 Product Features
Physical Port
5-port 10/100BASE-TX RJ45 with auto MDI/MDI-X
function (ISW-501T)
8-port 10/100BASE-TX RJ45 with auto MDI/MDI-X
function (ISW-801T)
1.3 Product Specications
Model ISW-501T ISW-801T
Hardware Specications
10/100BASE-TX Ports 5 8
3 x LED for System and Power: Green: DC Power 1
LED Indicators
Enclosure IP30-rated metal case
Dimensions (W x D x H)
Weight 400g 428g
ESD Protection 6KV DC
EFT Protection 6KV DC
Power Requirements
Power Consumption/ Dissipation
Installation DIN rail kit and wall-mount ear
Alarm
Connector
Green: DC Power 2 Green: Power Fault 1 x LED per Copper Port Green: 10/100 LNK/ACT
135 x 87 x 32 mm
12~48V DC, redundant power with polarity reverse protection function, 24V AC power support
1.6 watts/5.4BTU 2.1 watts/7.1BTU
Provides one relay output for power failure Alarm relay current carry ability: 3A @ DC 30V
Removable 6-pin terminal block Pin 1/2 for Power 1; Pin 3/4 for fault alarm; Pin 5/6 for Power 2
2. Hardware Introduction
2.1 Switch Front Panel
Figures 2-1 and 2-2 show the front panels of Industrial Fast Ethernet Switches.
P1 P2 FAULT
1
2
3
4
5
10/100
LNK ACT
ISW-501T
Figure 2-1: ISW-501T Front
Panel
Figure 2-2: ISW-801T Front
10/100
LNK ACT
Panel
P1 P2 FAULT
1
2
3
4
5
6
7
8
ISW-801T
3. Installation
3.1 Wiring the Power Inputs
The Upper Panel of the Industrial Fast Ethernet Switch indicates a DC inlet power socket and consists of one terminal block connector within 6 contacts. Please follow the steps below to insert the power wire.
1. Insert positive/negative DC power wires into Contacts 1 and 2 for Power 1 or 5, and 6 for Power 2.
1 2 3 4 5 6
V1+ V1- V2+ V2-
PWR1
2. Tighten the wire-clamp screws for preventing the wires from loosening.
1 2 3 4 5 6
V1+ V1- V2+ V2-
Power 1 Fault Power 2
PWR2Fault
Input DC12~48V, AC 24V
- 1 -
Layer 2 Features
Complies with IEEE 802.3 10BASE-T, IEEE 802.3u
100BASE-TX Ethernet standard
Supports auto-negotiation and 10/100Mbps half/full
duplex mode
High performance Store and Forward architecture,
runt/CRC ltering eliminates erroneous packets to
optimize the network bandwidth
Prevents packet loss with back pressure (half-duplex)
and IEEE 802.3x pause frame ow control (full-du­plex)
Backplane (switching fabric): ISW-501T: 1Gbps,
ISW-801T: 1.6Gbps
Automatic address learning and address aging
Industrial Case & Installation
IP30 metal case
DIN rail and wall-mount design
12 to 48V DC, redundant power with polarity reverse
protect function and connective removable terminal block for master and slave power, 24V AC power support
Lower Power Consumption device under full loading
operation mode
Supports EFT protection for 6000 VDC for power line
Supports 6000 VDC Ethernet ESD protection
-40 to 75 degrees C operating temperature
Free fall, shock-proof and vibration-proof for industries
- 3 -
Switch Specications
Switch Processing Scheme
Address Table 1K
Buffer Memory Embedded 448K bits packet buffer
Flow Control
Switch Fabric 1Gbps 1.6Gbps
Throughput (packet per second)
Network Cables
Standards Conformance
Standards Compliance
Temperature
Humidity
Regulatory Compliance
Stability Testing
Store-and-Forward
Back pressure for half duplex, IEEE 802.3x pause frame for full duplex
0.74Mpps 1.19Mpps
10BASE-T: 2-pair UTP Cat. 3, 4, 5, up to
100 meters
100BASE-TX: 2-pair UTP Cat. 5, 5e up to
100 meters
IEEE 802.3 Ethernet IEEE 802.3u Fast Ethernet IEEE 802.3x Full Duplex Flow Control
IEEE 802.3az Energy Efcient Ethernet
Operating: -40~75 degrees C Storage: -40~75 degrees C
Operating: 5% to 95%, Storage: 5% to 95% (non-condensing)
FCC Part 15 Class A, CE
IEC60068-2-32 (free fall) IEC60068-2-27 (shock) IEC60068-2-6 (vibration)
- 5 -
2.2 LED Indicators
LED Color Function
P1 Green Lit: indicates Power 1 has power.
P2 Green Lit: indicates Power 2 has power.
FAULT Green
10/100 LNK/ ACT
Lit: indicates either Power 1 or Power 2 has no
power.
Lit: indicates the port is successfully connecting to
the network at 100Mbps or 10Mbps.
Off: indicates that the port is not successfully
Green
connecting to the network at 100Mbps or 10Mbps.
Blinking: indicates that the port is actively
sending or receiving data.
2.3 Switch Upper Panel
The upper panel of the Industrial Fast Ethernet Switch consists of one terminal block connector within two DC power inputs.
Figure 2-3 shows the upper panel of the Industrial Fast Ethernet Switch.
1 2 3 4 5 6
V1+ V1- V2+ V2-
PWR1
Figure 2-3: Industrial Fast Ethernet Switch Upper Panel
PWR2Fault
Input DC12~48V, AC 24V
- 7 -
The wire gauge for the terminal block should
Note
be in the range between 12 and 24 AWG.
3.2 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal block connector as the picture shows below. Inserting the wires, the Industrial Fast Ethernet Switch will detect the fault status of the power failure and then forms an open circuit. The following illustration shows an application example for wiring the fault alarm contacts.
Insert the wires into the fault alarm contacts
1. The wire gauge for the terminal block should be in the range between 12 and 24 AWG.
Note
2. Alarm relay circuit accepts up to 30V, max. 3A currents.
- 2 -
- 4 -
- 6 -
- 8 -
The Fault Alarm Contacts are energized (CLOSE) for normal
Fault Alarm Contacts
Fault
operation and will OPEN when failure occurs
3.3 DIN-rail Mounting Installation
The DIN rail is screwed on the Industrial Fast Ethernet Switch when out of factory. When you need to replace the wall mount application with DIN-rail application on Industrial Fast Ethernet, please refer to the following gures to screw the DIN rail on the Industrial Fast Ethernet Switch. To hang the Industrial Fast Ethernet Switch, follow the steps below:
Step 3: Check whether the DIN rail is tightly on the track.
Step 4: Please refer to the following procedures to remove
the Industrial Fast Ethernet Switch from the track.
1
2
Step 5: Lightly pull out the bottom of DIN rail to remove it
from the track.
3.4 Wall-mount Plate Mounting Installation
To install the Industrial Fast Ethernet Switch on the wall, please follow the instructions described below.
Step 1: Remove the DIN rail from the Industrial Fast
Ethernet Switch; loosen the screws to remove the DIN rail.
- 9 -
Step 1: Screw the DIN rail on the Industrial Fast Ethernet
Switch.
1
2
Step 2: Place the bottom of DIN rail lightly into the track.
- 11 -
Step 2: Place the wall-mount plate on the rear panel of
the Industrial Fast Ethernet Switch.
Step 3: Use the screws to screw the wall-mount plate on
the Industrial Fast Ethernet Switch.
Step 4: Use the hook holes at the corners of the wall-
mount plate to hang the Industrial Fast Ethernet Switch on the wall.
Step 5: To remove the wall-mount plate, reverse the steps
above.
Customer Support
Thank you for purchasing PLANET products. You can browse
our online FAQ resource at PLANET Web site rst to check
if it could solve your issue. If you need more support information, please contact PLANET switch support team.
PLANET online FAQ : http://www.planet.com.tw/en/support/faq.php?type=1
Switch support team mail address : support_switch@planet.com.tw
EC Declaration of Conformity
For the following equipment:
*Type of Product: 5/8-Port 10/100Mbps Industrial Ethernet Switch *Model Number: ISW-501T, ISW-801T
* Produced by: Manufacturer‘s
Name : Planet Technology Corp.
Manufacturer‘s Address: 10F., No.96, Minquan Rd., Xindian Dist.,
is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility Directive on (2004/108/EC). For the evaluation regarding the EMC, the following standards were applied:
EN 55022 (Class A:2010/AC:2011) EN 61000-3-2 (2014) EN 61000-3-3 (2013) EN 55024 (2010)
Responsible for marking this declaration if the:
Manufacturer  Authorized representative established within the EU
Authorized representative established within the EU (if applicable):
Company Name: Planet Technology Corp.
Company Address: 10F., No.96, Minquan Rd., Xindian Dist., New Taipei City 231, Taiwan
Person responsible for making this declaration
Name, Surname Kent Kang
Position / Title : Director
New Taipei City 231, Taiwan (R.O.C.)
IEC 61000-4-2 (2008) IEC 61000-4-3 (2006+A1:2008+A2:2010) IEC 61000-4-4 (2012) IEC 61000-4-5 (2005) IEC 61000-4-6 (2013) IEC 61000-4-8 (2009) IEC 61000-4-11 (2004)
(R.O.C.)
- 10 -
Copyright © PLANET Technology Corp. 2016. Contents are subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.
- 12 - - 13 -
Taiwan 25 March, 2016
Place Date Legal Signature
PLANET TECHNOLOGY CORPORATION
10F., No.96, Minquan Rd., Xindian Dist., New Taipei City, Taiwan, R.O.C. Tel:886-2-2219-9518 Fax:886-2-2219-9528
e-mail: sales@planet.com.tw http://www.planet.com.tw
Loading...