2.ProductSpecications
Product ISW-1600T IFGS-1822TF
Fast Ethernet Copper Ports
Gigabit Ethernet Copper Ports
SFP Slots --
Switch Architecture Store-and-Forward
Switch Fabric
Throughput (packet per second)
Address Table
Shared Data Buer 4Mbits
16 10/100BASE-TX RJ45 auto-MDI/MDI-X ports
Two
10/100/1000BASE-T
--
RJ45 auto-MDI/MDI-X ports (shared with Port-17 and Port-18)
Two 1000BASE-SX/ LX/BX SFP interfaces (shared with Port-17 and Port-18)
3.2Gbps (non-blocking)
7.2Gbps (non-blocking)
2.38Mpps@ 64 bytes 5.36Mpps@ 64 bytes
16K entries, automatic source address learning and aging
IEEE 802.3 10BASE-T IEEE 802.3u 100BASE-TX IEEE 802.3ab Gigabit
1000T
IEEE 802.3z Gigabit SX/LX IEEE 802.3x ow control and back pressure IEEE 802.1p Class of
Standards Compliance
IEEE 802.3 10BASE-T IEEE 802.3u 100BASE-TX IEEE 802.3x ow control and back pressure IEEE 802.1p Class of Service IEEE 802.3az Energy Ecient Ethernet (EEE)
Service IEEE 802.3az Energy Ecient Ethernet (EEE)
Environment
Operating Temperature
Storage
Temperature
-40 ~ 75 degrees C
-40 ~ 85 degrees C
Humidity 5 ~ 95% (non-condensing)
3.2 LEDDenition:
System
LED Color Function
DC1 Green Lights to indicate DC power input 1 has power.
DC2 Green Lights to indicate DC power input 2 has power.
Fault Red
Per 10/100BASE-TX Port
LED Color Function
LNK/ ACT
100 Speed
Green
Amber
Lights to indicate that AC or DC power has failed.
Lights to indicate the link through that port is successfully established.
Blinking to indicate that the switch is actively sending or receiving data over that port.
O to indicates that the port is linked down.
Lights to indicate that the port is operating at
100Mbps.
O to indicates that the port is operating at
10Mbps.
O to indicates that the port is linked down.
- 1 -
1. Package Contents
Thank you for purchasing PLANET Industrial Multi-port 10/100TX Fast Ethernet Switch, ISW-1600T/IFGS-1822TF. In the following sections, the term “Industrial Ethernet Switch” means the
ISW-1600T or IFGS-1822TF.
Open the box of the Industrial Ethernet Switch and carefully unpack it. The box should contain the following items:
Industrial Ethernet
Switch x 1
RJ45 Dust Cap x 16 DIN-rail Kit SFP Dust Cap x 2
If any of these are missing or damaged, please contact your dealer immediately; if possible, retain the carton including the original packing material, and use them again to repack the product in case there is a need to return it to us for repair.
User’s Manual x 1 Wall-mount Kit x 1
(IFGS-1822TF only)
- 3 -
Flow Control
IEEE 802.3x pause frame for full-duplex Back pressure for half-duplex
ESD Protection 6KV DC
Enclosure IP30 metal case
Installation DIN-rail kit and wall-mount kit
Removable 6-pin terminal block for power
Connector
input Pin 1/2 for Power 1, Pin 3/4 for fault alarm, Pin 5/6 for Power 2
Alarm
Dimensions (W x D x H)
One relay output for power failure. Alarm relay current carry ability: 1A @ 24V DC
66 x 107 x 152 mm 66 x 107 x 152 mm
Weight 255g 300g
Power
Requirements
Power
Consumption
Dual 12~48V DC, 24V AC
Max. 5.3 watts/18BTU (Ethernet full loading)
Max. 6.3 watts/21.4BTU (Ethernet full loading)
Standards Conformance
Regulatory Compliance
FCC Part 15 Class A, CE
IEC60068-2-32 (free fall)
Stability Testing
IEC60068-2-27 (shock) IEC60068-2-6 (vibration)
- 5 -
3. Hardware Introduction
3.1 Switch Front Panel
The front panel of the Industrial Ethernet Switch consists of Ethernet interfaces and LED indicators.
Front View
P1 P2 Fault
1
3
5
7
9
11
13
15
100
2
4
6
8
10
12
14
16
ACTLNK
ISW-1600T
Figure1:
ISW-1600T Front View
P1 P2 Fault
1
3
5
7
9
11
13
15
100
2
4
1000X
6
17
挖孔
8
1000T
17
10
1000
ACTLNK
12
14
16
ACTLNK
18
18
IFGS-1822TF
Figure2:
IFGS-1822TF Front View
- 7 -
Per Gigabit RJ45/SFP Combo Interface (Port-17~Port-18 of IFGSW-1822TF)
LED Color Function
Lights to indicate the link through that port is successfully established.
LNK/ ACT
Green
Blinking to indicate that the switch is actively sending or receiving data over that port.
O to indicates that the port is linked down.
Lights to indicate that the port is operating at
1000Mbps.
1000 Speed
Amber
O to indicates that the port is operating at
10/100Mbps.
O to indicates that the port is linked down.
3.3 Switch Upper Panel
The upper panel of the Industrial Ethernet Switch consists of one terminal block connector within two power input and one relay
ouput.
Max. fault loading: 24V, 1A
1 2 3 4 5 6
V1+ V1- V2+ V2-
PWR1
PWR2Fault
Figure3: ISW-1600T and IFGS-1822TF Top View
DC Input: 12-48V AC Input: 24V
, 1A max.
, 2A max.
- 2 -
- 4 -
- 6 -
- 8 -
3.4 Wiring the Power Inputs
The 6-contact terminal block connector on the top panel of Industrial Ethernet Switch is used for two DC redundant power inputs. Please follow the steps below to insert the power wire.
When performing any of the procedures like inserting the wires or tightening the wire-clamp screws, make sure the power is OFF to prevent from getting an electric shock.
1. Insert positive and negative DC power wires into contacts 1 and 2 for POWER 1, or contacts 5 and 6 for POWER 2.
Max. fault loading: 24V, 1A
1 2 3 4 5 6
4. Installation
This section describes the functionalities of the Industrial Ethernet Switch’s components and guides you to installing it on the DIN rail and wall. Please read this chapter completely before continuing.
This following pictures show how to install the device. However, the device in the picture is not ISW-1600T
Note
4.1 DIN-rail Mounting Installation
or IFGS-1822TF.
1
V1+ V1- V2+ V2-
PWR1
PWR2Fault
DC Input: 12-48V AC Input: 24V
, 1A max.
, 2A max.
2. Tighten the wire-clamp screws for preventing the wires from loosening.
1 2 3 4 5 6 Power 1 Fault Power 2 + - + -
- 9 -
1. The wire gauge for the terminal block should be in the range between 12 and 24 AWG.
2. The power input range is 12V ~ 48V DC and
Note
supports 24V AC.
3. Use one power input when using 24V AC.
3.5 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal block connector as the picture shows below. Inserting the wires, the Industrial Ethernet Switch will detect the fault status of the power failure and then forms an open circuit. The following illustration shows an application example for wiring the fault alarm contacts.
1 2 3 4 5 6
2
- 11 -
4.2 Wall-mount Plate Mounting
4.3 Side Wall-mount Plate Mounting
5. Customer Support
Thank you for purchasing PLANET products. You can browse our online FAQ resource on PLANET web site rst to check if it could solve your issue. If you need more support information, please contact PLANET switch support team.
PLANET online FAQ: http://www.planet.com.tw/en/support/faq
Switch support team mail address: support@planet.com.tw
FCC Warning
This equipment has been tested and found to comply with the regulations for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this user’s guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.
CE Mark Warning
This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.
Fault Alarm Contacts
1. The wire gauge for the terminal block should be in
Note
2. Alarm relay circuit accepts up to 24V DC,1A
The Fault Alarm Contacts are energized (CLOSE) for normal operation and will OPEN when
Fault
failure occurs
Insert the wires into the fault alarm contacts
the range between 12 and 24 AWG.
- 10 -
WEEE Warning
To avoid the potential eects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment, end
users of electrical and electronic equipment should understand the meaning of the crossed-out wheeled bin symbol. Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately.
Copyright © PLANET Technology Corp. 2019.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.
- 12 - - 13 - - 14 -
Loading...