2.ProductSpecications
Product ISW-1600T IFGS-1822TF
Hardware Specications
Fast Ethernet
Copper Ports
Gigabit Ethernet
Copper Ports
SFP Slots --
Switch Architecture Store-and-Forward
Switch Fabric
Throughput
(packet per
second)
Address Table
Shared Data Buer 4Mbits
16 10/100BASE-TX RJ45 auto-MDI/MDI-X
ports
Two
10/100/1000BASE-T
--
RJ45 auto-MDI/MDI-X
ports
(shared with Port-17
and Port-18)
Two 1000BASE-SX/
LX/BX SFP interfaces
(shared with Port-17
and Port-18)
3.2Gbps
(non-blocking)
7.2Gbps
(non-blocking)
2.38Mpps@ 64 bytes 5.36Mpps@ 64 bytes
16K entries, automatic source address
learning and aging
IEEE 802.3 10BASE-T
IEEE 802.3u
100BASE-TX
IEEE 802.3ab Gigabit
1000T
IEEE 802.3z Gigabit
SX/LX
IEEE 802.3x ow
control and back
pressure
IEEE 802.1p Class of
Standards
Compliance
IEEE 802.3 10BASE-T
IEEE 802.3u
100BASE-TX
IEEE 802.3x ow
control and back
pressure
IEEE 802.1p Class of
Service
IEEE 802.3az Energy
Ecient Ethernet
(EEE)
Service
IEEE 802.3az Energy
Ecient Ethernet
(EEE)
Environment
Operating
Temperature
Storage
Temperature
-40 ~ 75 degrees C
-40 ~ 85 degrees C
Humidity 5 ~ 95% (non-condensing)
3.2 LEDDenition:
System
LED Color Function
DC1 Green Lights to indicate DC power input 1 has power.
DC2 Green Lights to indicate DC power input 2 has power.
Fault Red
Per 10/100BASE-TX Port
LED Color Function
LNK/
ACT
100
Speed
Green
Amber
Lights to indicate that AC or DC power has
failed.
Lights to indicate the link through that port is
successfully established.
Blinking to indicate that the switch is actively
sending or receiving data over that port.
O to indicates that the port is linked down.
Lights to indicate that the port is operating at
100Mbps.
O to indicates that the port is operating at
10Mbps.
O to indicates that the port is linked down.
- 1 -
1. Package Contents
Thank you for purchasing PLANET Industrial Multi-port 10/100TX
Fast Ethernet Switch, ISW-1600T/IFGS-1822TF. In the following
sections, the term “Industrial Ethernet Switch” means the
ISW-1600T or IFGS-1822TF.
Open the box of the Industrial Ethernet Switch and carefully
unpack it. The box should contain the following items:
Industrial Ethernet
Switch x 1
RJ45 Dust Cap x 16 DIN-rail Kit SFP Dust Cap x 2
If any of these are missing or damaged, please contact your dealer
immediately; if possible, retain the carton including the original
packing material, and use them again to repack the product in case
there is a need to return it to us for repair.
User’s Manual x 1 Wall-mount Kit x 1
(IFGS-1822TF only)
- 3 -
Flow Control
IEEE 802.3x pause frame for full-duplex
Back pressure for half-duplex
ESD Protection 6KV DC
Enclosure IP30 metal case
Installation DIN-rail kit and wall-mount kit
Removable 6-pin terminal block for power
Connector
input
Pin 1/2 for Power 1, Pin 3/4 for fault alarm,
Pin 5/6 for Power 2
Alarm
Dimensions
(W x D x H)
One relay output for power failure. Alarm
relay current carry ability: 1A @ 24V DC
66 x 107 x 152 mm 66 x 107 x 152 mm
Weight 255g 300g
Power
Requirements
Power
Consumption
Dual 12~48V DC, 24V AC
Max. 5.3
watts/18BTU
(Ethernet full
loading)
Max. 6.3
watts/21.4BTU
(Ethernet full
loading)
Standards Conformance
Regulatory
Compliance
FCC Part 15 Class A, CE
IEC60068-2-32 (free fall)
Stability Testing
IEC60068-2-27 (shock)
IEC60068-2-6 (vibration)
- 5 -
3. Hardware Introduction
3.1 Switch Front Panel
The front panel of the Industrial Ethernet Switch consists of
Ethernet interfaces and LED indicators.
Front View
P1 P2 Fault
1
3
5
7
9
11
13
15
100
2
4
6
8
10
12
14
16
ACTLNK
ISW-1600T
Figure1:
ISW-1600T Front View
P1 P2 Fault
1
3
5
7
9
11
13
15
100
2
4
1000X
6
17
挖孔
8
1000T
17
10
1000
ACTLNK
12
14
16
ACTLNK
18
18
IFGS-1822TF
Figure2:
IFGS-1822TF Front View
- 7 -
Per Gigabit RJ45/SFP Combo Interface
(Port-17~Port-18 of IFGSW-1822TF)
LED Color Function
Lights to indicate the link through that port is
successfully established.
LNK/
ACT
Green
Blinking to indicate that the switch is actively
sending or receiving data over that port.
O to indicates that the port is linked down.
Lights to indicate that the port is operating at
1000Mbps.
1000
Speed
Amber
O to indicates that the port is operating at
10/100Mbps.
O to indicates that the port is linked down.
3.3 Switch Upper Panel
The upper panel of the Industrial Ethernet Switch consists of one
terminal block connector within two power input and one relay
ouput.
Max. fault loading: 24V, 1A
1 2 3 4 5 6
V1+ V1- V2+ V2-
PWR1
PWR2Fault
Figure3: ISW-1600T and IFGS-1822TF Top View
DC Input: 12-48V
AC Input: 24V
, 1A max.
, 2A max.
- 2 -
- 4 -
- 6 -
- 8 -
3.4 Wiring the Power Inputs
The 6-contact terminal block connector on the top panel of
Industrial Ethernet Switch is used for two DC redundant power
inputs. Please follow the steps below to insert the power wire.
When performing any of the procedures like inserting
the wires or tightening the wire-clamp screws, make
sure the power is OFF to prevent from getting an
electric shock.
1. Insert positive and negative DC power wires into contacts 1 and
2 for POWER 1, or contacts 5 and 6 for POWER 2.
Max. fault loading: 24V, 1A
1 2 3 4 5 6
4. Installation
This section describes the functionalities of the Industrial Ethernet
Switch’s components and guides you to installing it on the DIN rail
and wall. Please read this chapter completely before continuing.
This following pictures show how to install the device.
However, the device in the picture is not ISW-1600T
Note
4.1 DIN-rail Mounting Installation
or IFGS-1822TF.
1
V1+ V1- V2+ V2-
PWR1
PWR2Fault
DC Input: 12-48V
AC Input: 24V
, 1A max.
, 2A max.
2. Tighten the wire-clamp screws for preventing the wires from
loosening.
1 2 3 4 5 6
Power 1 Fault Power 2
+ - + -
- 9 -
1. The wire gauge for the terminal block should be in
the range between 12 and 24 AWG.
2. The power input range is 12V ~ 48V DC and
Note
supports 24V AC.
3. Use one power input when using 24V AC.
3.5 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal block
connector as the picture shows below. Inserting the wires, the
Industrial Ethernet Switch will detect the fault status of the power
failure and then forms an open circuit. The following illustration
shows an application example for wiring the fault alarm contacts.
1 2 3 4 5 6
2
- 11 -
4.2 Wall-mount Plate Mounting
4.3 Side Wall-mount Plate Mounting
5. Customer Support
Thank you for purchasing PLANET products. You can browse our
online FAQ resource on PLANET web site rst to check if it could
solve your issue. If you need more support information, please
contact PLANET switch support team.
PLANET online FAQ:
http://www.planet.com.tw/en/support/faq
Switch support team mail address:
support@planet.com.tw
FCC Warning
This equipment has been tested and found to comply with the
regulations for a Class A digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed
and used in accordance with this user’s guide, may cause harmful
interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference, in which
case the user will be required to correct the interference at his own
expense.
CE Mark Warning
This is a Class A product. In a domestic environment, this product
may cause radio interference, in which case the user may be
required to take adequate measures.
Fault Alarm Contacts
1. The wire gauge for the terminal block should be in
Note
2. Alarm relay circuit accepts up to 24V DC,1A
The Fault Alarm Contacts are
energized (CLOSE) for normal
operation and will OPEN when
Fault
failure occurs
Insert the wires into the fault alarm contacts
the range between 12 and 24 AWG.
- 10 -
WEEE Warning
To avoid the potential eects on the environment and
human health as a result of the presence of hazardous
substances in electrical and electronic equipment, end
users of electrical and electronic equipment should
understand the meaning of the crossed-out wheeled bin symbol. Do
not dispose of WEEE as unsorted municipal waste and have to
collect such WEEE separately.
Copyright © PLANET Technology Corp. 2019.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.