Pilz P1WM Data Sheet

Electronic Monitoring Relays
True power monitoring
P1WM
Technical Details P1WM
Electrical data
Measuring voltage = supply voltage 3 AC/1 AC: 42, 110, 230, 400, 415, 500,
Tolerance 85 ... 110 % Power consumption Approx. 5 VA Switching capability in accordance with EN 60947-4-1, 10/91 AC1: 240 V/0.1 ... 5 A/1100 VA
Output contacts 1 auxiliary contact (C/O) Contact fuse protection in accordance 6 A quick or 4 A slow with EN 60947-5-1, 10/91 Max. switch-on current 10 A AC
Measuring circuit
Adjustable measuring range limit values
True power monitor for 1- and 3-phase supplies for monitoring maximum true power values
Features
Direct measurement of motors
Output signal either latching or
non-latching
Adjustable reaction times
Trip device if overload occurs
Operates to normally energised
or normally de-energised mode
Suitable for current transformers
Max. overload 1 A version: 1.2 A, 6 A/max. 3 s
Response delay 1A version: 0.25 ... 3 s adjustable
Start-up suppression time 0.5 ... 20 s adjustable Requirement for current transformer 1 A version: 1.5 ... 7.5 VA
Mechanical data
Max. cable cross section 2 x 2.5 mm of external conductor Single-core or multi-core with crimp
Torque setting for connection terminals 1.2 Nm (screws) Dimensions (H x W x D) 75 x 90 x 115 mm Weight 470 g
550 VAC
DC1: 24 V/0.1 ... 1 A/240 W
1 A version: 5 A version: 0 ... 1; 1.1 ... 3; 3.3 ... 5 A
5 A version: 6 A, 25 A/max. 3 s
5 A version: 0.25 ... 30 s adjustable
5 A version: 2.5 ... 15 VA
connector
0...0.35; 0.25...0.7; 0.67...1 A
2
4
Description
The P1WM true power monitor is enclosed in a 90 mm wide P-75 housing. All three external conduc­tors are used as the supply voltage. There are 7 versions available for use with 3-phase AC voltage supplies. Features:
Relay output: 1 auxiliary contact
(C/O)
2 versions with adjustable
measuring ranges up to max. 1 A or up to max. 5 A
Overload switching points
Adjustable response delay
Adjustable start-up suppression
time
Automatic or manual reset
LED-display for supply voltage
and switching status of the auxiliary contacts P
max
The P1WM monitors whether true power exceeds a defined level in AC or 3-phase current loads. The signal, which is proportional to the true power, is derived by multiplying the voltage and current. The maximum permitted true power P using a potentiometer. If the measured true power PW exceeds the preset value P switches and the red LED will be on.
, the output relay K1
max
max
is set
Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland NSG-D-2-253-10/00 Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de
Electronic Monitoring Relays
True power monitoring
P1WM
Internal wiring diagram
L1
k
I
I
M
M
U
L1
U
I
I
int
n*I
I
M
int
U(I)
Y1 Y2
L1
L2
L3
Power supply
cos j*k
L1 *
int
*
t
a
+
0
P
& &
P
max
P
max-PW
DP
max
t
r
Control logic
14
12
K1
11
Y3 Y4 Y5
4
W
V
I
Measuring currents
M
n Measuring range factor UL1Measuring voltages
Timing diagram
Measuring circuit
Operating voltage U
B
Output P
Output P
(K1, RB)
max
(K1, AB)
max
RB Normally energised mode AB Normally de-energised mode P
Response value, overload
max
UL1Measuring voltage at L1
N
cos j Power factor k Correction factor
Start-up suppression time
t
a
P
max
P
min
0
1
0
1
0
1
0
t
a
I
M
I
int
cos j Power factor
t
r
PW > P
Measuring current Internal measuring current
max
k Correction factor
PWTrue power P
Max. True power
max
t
Response delay
r
n Measuring range factor
Start-up suppression time
t
a
t
Response delay
r
Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland NSG-D-2-253-10/00 Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de
Loading...
+ 3 hidden pages