Track
RCS350/ZRS350
Installation Instruction 安装说明
Type NO.
型号
RCS350 3C L1000 WH 1000A 1.2
RCS350 3C L2000WH
RCS350 3C L3000WH
ZRS350 3C TCPWH T COUPLER
ZRS350 3C CPX WH X COUPLER
ZRS350 3C CCPWH L COUPLER
ZRS350 3C EPSWH SUPPLY
ZRS350 3C CPS WH SUPPLY CENTRAL
Mounting
安装方式
Surface
Surface 380V~415V 50/60Hz220~240V
Surface 380V~415V 50/60Hz220~240V
Surface 380V~415V 50/60Hz220~240V
Surface
Surface 380V~415V 50/60Hz220~240V
Surface
Surface
A
42.5
34
B D
30.8
34
102.5
70
1Phase Vol
1相电压
220~240V
C
3Phase Vol
Frenquency频率Max Current
3相电压
380V~415V 50/60Hz 16A
380V~415V 50/60Hz220~240V
380V~415V 50/60Hz220~240V
380V~415V 50/60Hz220~240V
126
L
41.5
185
120
42.542.5
34
最大
16A
16A
16A
16A
16A
16A
16A
Figure
外型
35.7
A
A
E
F
D
B
C
103.7
L(mm)
2000
3000
2.4
3.6
0.2
0.14
0.14
0.07
0.27
34
IP
防护等级
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
35.7
E F
113.7
185
41.5
34
120
42.5
1. Ensure that the luminaire is consistent with the track system in electric ,machine and temperature when mounting
and using.
安装和使用前,要保证灯具和轨道系统连接之间电器、机械、热的相容性。
2. The track system is only used to the track projector luminare of Philips.
此轨道系统仅使用于飞利浦的轨道投射灯。
Philips Lighting Luminaires (Shanghai) Co., Ltd.
Address: No. 2688, Huyi Road, Jiading, Shanghai, China
Postalcode: 201801
飞利浦灯具(上海)有限公司
地址:中国上海市嘉定区马陆镇沪宜公路2688号
邮编:201801
113.7
42.5
41.5
34
185
120
41.5
185
42.5
1
a
Ø3.5
b
L=1000mm L=1000mm
200100
50N 50N 50N 50N 50N 50N 50N 50N 50N 50N 50N 50N
2
2 2
3
L1
N
220V, 16A, 3x3.5 KW
230V, 16A, 3x3.7 KW
240V, 16A, 3x3.8 KW
L2
L1
L3
Max.16A
N
3-circuit(3路)
1
5
220~2401V, 6A, 3.5~3.8 KW
L2
L3
L
N
Out 220/In 380V, 16A, 10.6 KW
Out 230/In 400V, 16A, 11.0 KW
Out 240/In 415V, 16A, 11.5 KW
L2
L1
L3
N
1
2
3
Max.16A
1-circuit(1路)
Max.16A
3-phase(3相)
a
b
1
When the track connect 3 phase supply, the load for every
phase must be so equal that 3 phase voltage be balanceable
轨道连接3相电源时,必须使每相的负载相等,
以使3相电压平衡
4
1
3
2
1
c
2
d
4