PRODUCT INFORMATION
- This product meets the requirements regarding interference suppression on radio and TV.
TECHNICAL INFORMATION
- Voltage : 120 V
- Frequency : 60 Hz
- Power consumption : 1450 W
- Standby power consumption : < 1W
- Contents reservoir : 750 cc
- Colour setting : Deep Red
- SAP coding : HD7811/94
OPTIONAL (accessories)
- XL watertank (10 Cups) Commercial type number HD7982 Service code : 4222 259 20100
L
Pump
N
Water level Sensor
M
CONTROL
PCB
Push buttons
Temp. Sensor
TCO
Boiler
Fuse
Fuse
Published by Philips Consumer Lifestyle Printed in the Netherlands © Copyright reserved Subject to modification
10/05
DISASSEMBLY- AND RE-ASSEMBLY ADVISE
Disassembly information
HD7811/94
To remove the brew chamber lid cover handle as follows:
- Place the screwdriver on the positions (see picture 1) and lift the cover over the snap locks on both positions.
picture 1
- The cover lid can now be lifted up a little and to remove the complete cover including lever and push rod squeeze strongly with two fingers both legs of the push rod (see picture 2) to each other, so that the two pins will get out of the hinge position on the brew chamber.
- To remove lever from lid cover, take a screwdriver and bend carefully the two lips/ribs in the lid cover outwards and push the lever with force out of the hinge.
- Reassemble follow steps backwards, without using a screwdriver.
To remove the back cover handle as follows:
- Remove valve outlet.
- Start at the upper side of the back cover and stick a screwdriver into the 2 snap locks positions and gently pull the back cover from the appliance so that a little chink between back cover and brew chamber becomes visible.
- Put the screwdriver in to the 4 rectangular holes (snap locks) at the back and gently pull the screwdriver such away that the lips of the snap locks are bent outwards.
- If all clicks positions are loose, it is possible to remove the back cover.
- Reassemble follow steps backwards.
picture 2
Removing Brew chamber head handle as follows:
- Disassemble back cover!
- Place the appliance such a way that you are looking at the boiler.
- First remove the boiler from the snap lock position of the brew chamber.
- To remove the brew chamber, use your both thumbs (see picture 3) and push strongly with a little distortion (rotation) until the brew chamber comes loose.
- Reassemble follow above steps backwards.
To reach the components placed on the base handle as follows:
- First remove back cover, brew chamber and 3-way valve.
- Remove both Torx T15 screws see exploded view in the near of position A.
- Bend the 2 click snap locks with a screwdriver (see base), and the housing can now be removed.
- To remove the rest of the housing unlock the last 4 snap locks at the base and gently pull of the front cover.
- To reassemble follow above steps backwards.
picture 3