Philips GC3006 Service Manual

Steam Iron Elance
GC3006
Philips Domestic Appliances and Personal Care
Service Manual
PRODUCT INFORMATION
Features
- Careeza soleplate
- Tank capacity (300 ml)
- Steam rate (30 g/min)
- Shot of steam (75 g/min)
- Integrated cord winder
- Cord length : 2 m.
Safety Information
- This product meets the requirements regarding interference suppression on radio and TV.
- After the product has been repaired, it should function properly and has to meet the safety requirements and legal regulations as officially laid down at this moment.
TECHNICAL INFORMATION
Voltage : 220 - 240 V Frequency : 50 - 60 Hz Power consumption : 1800 W
Water advice
Suitable for tap water use. However if the tap water in your area is very hard, we advise you to mix it with a equal portion of distilled water or to use distilled water only.
Cleaning of the Iron
Use only the Calc clean button for cleaning of the Iron. Never use vinegar, starch or chemically descaled water.
Soleplate
Careeza is a multi layer chemical substance that gives an excellent gliding over various fabrics and better care for the garments.
Published by Philips Domestic Appliances and Personal Care Printed in the Netherlands © Copyright reserved Subject to modification
03/07
DISASSEMBLY ADVICE
GC3006
DIAL 1
BACKPLATE 2
CORD SET 3
SWIVEL 4
Remove Screw A (1x)
Remove BACKPLATE 2 Remove Screw B (2x) cord clamping
INLAY 5
LAMP ASSY 6
FILLING DOOR 7
STEAM SLIDER 8
LAMP COVER 9
SOS KNOB 10
SPRAY KNOB 11
TANK SEAL 12
remove Screw A (1x) remove BACKPLATE 2 remove Screw B (2x) cord clamping remove INLAY 5
DOSING UNIT 13
remove Screw A (1x) remove BACKPLATE 2 remove Screw B (2x) cord clamping remove INLAY 5 remove Screw C (2x) remove Screw D (2x) remove DOSING UNIT 13
TANK 17
THERMOSTAT BUSH 18
remove Screw A (1x) remove BACKPLATE 2 remove Screw B (2x) cord clamping remove INLAY 5 remove Screw C (2x) remove Screw D (2x) remove DOSING UNIT 13 remove Screw E (2x) remove HANDLE 14 remove Screw F (2x) remove TANK 17
SHIELD 19
remove Screw A (1x) remove BACKPLATE 2 remove Screw B (2x) cord clamping remove INLAY 5 remove Screw C (2x) remove Screw D (2x) remove DOSING UNIT 13 remove Screw E (2x) remove HANDLE 14 remove Screw F (2x) remove TANK 17 remove Screw G (1x) remove SHIELD 19
COVER 20
SOS SEAL 21
DOSING SEAL 22
SOLEPLATE ASSY 23
HANDLE 14
RATTLE SPRING 15
PUMP 16
remove Screw A (1x) remove BACKPLATE 2 remove Screw B (2x) cord clamping remove INLAY 5 remove Screw C (2x) remove Screw D (2x) remove DOSING UNIT 13 remove Screw E (2x) remove HANDLE 14
remove Screw A (1x) remove BACKPLATE 2 remove Screw B (2x) cord clamping remove INLAY 5 remove Screw C (2x) remove Screw D (2x) remove DOSING UNIT 13 remove Screw E (2x) remove HANDLE 14 remove Screw F (2x) remove TANK 17 remove Screw G (1x) remove SHIELD 19 remove Screw H (2x) remove COVER 20
2-4
Loading...
+ 2 hidden pages