Repair Scenario FTV with SDI PDP
First check complete set
Fault Symptom?
No
Repair Philips application
Scavio = FM242
SSB EMG = FTP1.1 (with LVDS tool??)
SSB EMG 2004 = FTP2.2 with LVDS Tool
Power Supply
is working ?
Check if LVDS from SCAVIO
or SSB board is OK
Use LVDS Tool when possible
Output of SSB / SCAVIO
is OK?
SDI repair Scenario
Fault finding; Display fault
No
Power supply is not working
No voltage output
Go to Power Supply Check
& repair scenario
With Philips application
or PDP as stand alone check
42FD9925/01
42FD9935/17/93S
42FD9945/01/12/69/79/98
42FD9953/17/69C/69S/93S
42FD9936/37
SD
FM242
42PF9945
SD
FTP1.1
Set Type ?
37PF9946/12
37PF9936/37
SD SD
LC4.7
42PF9966/37/
79/93/98
42PF9976/37
HD
FTP2.2
42PF9946/12/79/93/98
42PF9936D/37
42PF9956/12/93
FTP2..2
LC4.7
50PF9956/37
50PF9966/12/37/69/
93
50PF9986/37
HD
FTP2..2
Repair Scenario 42SDV2
VDS 25.10.04 Page 1
Repair Scenario SDV4
Repair Scenario SDV3
No Voltage output
Power Supply Check for 42SDV2
Operating voltages don´t exist
Check F8002
Fuse 250V/8A
On/Off relay
RLY8001/8002 acts?
Green LED´s
8001, 8002
are on?
Switch on On/Off switch (vacation switch)
SMPS shutsdown?
Red LED8004 is on
Connect set to mains.
LED8003
Stby is on?
Switch on via RC
Check Protection Red
LED8004
Protection failure.
No
Check CN8004 / 2pin
connector 220V AC
NO
Stanby supply is defective.
Replace PSU
No
Check Stanby Line
pin 11 on CN8002.
must be low
Yes
Call SAM
or SDM
Check SMPS outputs
Vs, Va, Vset, Ve, Vsc
see Sticker
Yes
Yes
Disconnect X-main CN8007
Disconnect VA Logic Buffer
Replace
PSU
Discharge capacitors on Power
supply via connector, before
reconnecting X, Y or Buffer board,
use discharge resistor
LED on Logic main
board is blinking?
Disconnect Y-main
CN8008
Vs/Vset/Vsc/Vcc
Vs/Vg/Vcc
CN8010 / CN8011
Power supply is operating
No
after disconnecting one
of these boards?
Check Power supply
on Logic main
Disconnect mains
reconnect mains
Switch on via RC
(again)
No
Use overview of PS
in wiring diagram
VDS 25.10.04 Page 2
Replace the defective board
Replace
PSU
No Voltage output
Power Supply Check for SDV3
Operating voltages don´t exist
Check CN8001 / 2pin connector 220V AC
On/Off relay
RLY8001/8002 acts?
Green LED´s
8001, 8002
are on?
Yes
Connect set to mains.
LED8003
Stby is on?
Switch on via RC
Protection failure.
SMPS shutsdown?
Red LED8004 is on
Check fuse F8001 / F8002 / 8003
NOK
Stanby supply is defective.
Replace PSU
No
Check Protection Red
LED8004
Check Stanby Line
on CN8004.
pin 13 must be low
Logic Main board LED
3,3V and 5V are on?
Call SAM
or SDM
reconnecting X, Y or Buffer board,
Check SMPS outputs
Vs, Va, Vset, Ve, Vsc /D5V
see Sticker
Yes
Replace
PSU
Discharge capacitors on Power
supply via connector, before
use discharge resistor
Disconnect X-main CN8002
Vs/Ve/Vcc/D5V
Disconnect Y-main
CN8003
Vs/Vset/Vsc/Vcc/D5V
Disconnect VA Logic Buffer
CN8005 / CN800x
Va
Power supply is operating
after disconnecting one
of these boards?
Disconnect mains
reconnect mains
Switch on via RC
(again)
No
Use overview of PS
in wiring diagram
VDS 25.10.04 Page 3
Replace the defective board
Replace
PSU