PRODUCT INFORMATION

-This product meets the requirements regarding interference suppression on radio and TV.

-After the product has been repaired, it should function properly and has to meet the safety requirements as officially laid down at this moment.

TECHNICAL INFORMATION

-

Colour

/A

: Mint green

 

Version

/B

: 2000 W logo

 

Colour

/C

: Titanium silver

-

Maximum air displacement

: 37 l/sec.

-Maximum vacuum water column : 310 cm

-Power consumption (IEC) 230 V : 1500 W

-

Duststorage capacity

:

3 L

-

Type number dustbag

:

FC8021

-

Cord length (depends on version) :

7 metres

-

Filter system

: Paper dustbag

 

 

: Exhaust HEPA

 

 

 

air filter

 

 

: Motor inlet filter

-

Dimensions of cleaner

:

460 x 315 x 270 mm

-

Dimensions of packaging

:

595 x 395 x 295 mm

-

Net weight

:

5.88 kg

-

Gross weight

:

9.135 kg

OPTIONAL (accessories)

- FC8021 S-bags

-FC8022 Clinic S-bags

-FC8023 Anti odour S-bag

-FC8025 S-fresh perfume

- FC8030 AFS-filter

-FC8031 HEPA Air Filter

-FC8034 Upgrate kit Active Carbon Filter

-FC8042 Polishing nozzle

-FC8043 Turbo brush nozzle

DISASSEMBLYAND RE-ASSEMBLY ADVISE

-

Open the appliance, first remove

 

 

the exhaust filter grille (item 20),

C 2x

 

and then remove the 2 screws -

 

 

C of the switch control panel

 

 

(item 15).

 

-

Undo and remove the 9 screws -

 

 

C in the upper housing (item 8).

 

 

You will require a screwdriver

 

 

with a 14.5 cm-long shank for

C 9x

 

this. Depending on the version

 

 

screwdriver 9965 000 08332 for

 

 

cross head or onwards 0234

 

 

screwdriver 4322 009 08490 for T15 can be used.

-The component configuration shown in the exploded view may differ in case of specific versions. The components are distinguished by means of code numbers.

-When the repair is finished, check whether all functions of the appliance work properly.

-To disassemble the cord winder, use TORX screwdriver no. T10, which is one of a set consisting of T20; T15; T10; T9; T8; T7 and T6 (code number 4822 395 50145).

Published by Philips Domestic Appliances and Personal Care

Printed in the Netherlands

© Copyright reserved

Subject to modification

04/02

Philips FC 9104 ABC, FC9104AC Service Manual
Ø 2mm

REPAIR INSTRUCTION

-Item 8 Spare part is standard supplied without a hole, you must drill a hole 2 mm dia, so

the air can reach the sensor on the PCB via the pressure tube.

-Item 22 Replace the HEPA filter as soon as the pilot light of the filterfull indicator goes on.

-Item 4, cotton dustbag, is used in countries in which paper dustbags are not available.

-If the reel half spring unit is replaced, shaft A must be lubricated with silicone grease. Do not apply any silicone grease to or spill any grease on terminals (43) or conductors (42).

-Item 40 is provided with a long cord-winder spring, but both long and short cords can be used in combination with this spring. (L = 9.3 m)

-Depending on the original cord, the spare cord must be shortened to the length of the original cord.

-The cord winder spring must be tensioned to the maximum level and then be rewound approx. 1.5 turn

-Item 13, air valve, opens to cool the motor if the air displacement is too low or if the airflow is blocked.

-To adjust the telescopic tube (item 59) to the required length, push the adjustment collar in the direction of the arrow while sliding the top section of the telescopic tube into or out of the lower section.

-If the function of the electronic control unit (item 12) is not required, the Triac must be short-circuited in the manner shown in the circuit diagram.

-When the vacuum cleaner is used to suck up fine dust the pores of the dustbag may become clogged, causing the passage of air through the dustbag to become obstructed. As a result, the dustbag-full indicator will indicate that the dustbag needs to be replaced, eventhough the dustbag is not full at all.

-Item 72, sealing ring must be replaced if appliance whistles.

ELECTRICAL DIAGRAM

Black

Black

M

MOTOR

CORD WINDER

 

Blue

 

 

 

 

POWER

 

 

 

 

MODULE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Brown

 

 

 

= changed

FC9104 /A /B /C

-Due to introduction of a new switch (item 11) 0320 onwards, which is not interchangable with the old switch soldered on the PCB (item 12).

-The switch lever assy (item 11a) is also modified.

To recognize the switches:

Old

New

13 mm

10 mm

To replace the knobs:

2

1

New spares are:

 

 

11

 

Switch soldered version

- 4322 006 50600

11a

Switch lever assy

- 4322 009 08980

parts of 15

Switch and Cord winder knob - 4322 009 09000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 