Schematic Diagrams and CBA's
Exploded Views
Mechanical and Electrical Parts Lists
Survey of versions:
/01 PAL-BG, EURO
/07 PAL I, Ireland
/39 PAL/SECAM-BG+PAL/SECAM-L/L',FRANCE
/58 PAL-BG/DK+SECAM-BG/DK,EAST-EURO
Sec. 2:
Standard Maintenance
Mechanism Alignment Procedures
Disassembly / Assembly of Mechanism
Deck Exploded Views
For technical data reference is made to the Service Manual of
14PV360/01/07/39 & 14PV365/01/07/39/58 3103 785 22040.
The present Manual states only the differences.
Safety regulations require that the set be restored to its original
condition and that parts which are identical with those specified
be used.
Published by BK 2002 Video Service Department Printed in the Netherlands c
Copyright reserved Subject to modification GB 3103 785 22120
To delete last entry/Clear programmed recording (TIMER).
To record the TV channel selected at this moment or press
repeatedly to start a One-Touch Recording.
STILL
To stop the tape and show a still picture.
P-P+
To select the programme number. During normal or slow motion
playback, press to adjust the tracking or vertical jitter.
MUTE
To eliminate the sound. Press again to restore the volume.
To adjust the volume.
9
SYSTEM
SLEEP
STANDBY/ON
MENU
STATUS/EXIT
Doesn’t work in these models.
To select the switch-off time in 30 minutes intervals.
y
To switch TVCR On or Off or to interrupt menu function.
To call up main menu of TVCR.
To access or remove the TVCR’s on-screen status display. To
exit on-screen menus.
0..9
Press to select channels.
When tape playback is stopped, press to fast forward the tape at hight
speed. During playback, press to fast forward the tape while the picture stay on
the screen. To store or confirm entry in the menu. Press to adjust the controls of
TVCR menu.
When tape playback is stopped, press to rewind the tape at high speed.
During playback, press to rewind the tape while the picture stay on the screen.To
p
l
o
return the cursor in the menu. Press to adjust the controls of TVCR menu.
To play a tape, select an item in the menu of TVCR.
To stop the tape, select an item in the menu of TVCR.
<14PV203, 14PV460>
TEXT
Yellow button/ Select TELETEXT function when you are in TELETEXT mode.
To switch TELETEXT on or off,or transparent mode.
o
l
p
: enlarge font
: switch TELETEXT decoder off temporarily
: Doesn’t work in these models.
: recall hidden information
"CBA" is abbreviation for "Circuit Board
Assembly."
NOTE:
Electrical adjustments are required after replacing
circuit components and certain mechanical parts.
It is important to perform these adjustments only
after all repairs and replacements have been completed.
Also, do not attempt these adjustments unless the
proper equipment is available.
Test Equipment Required
1. PAL Pattern Generator (Color Bar W/White Window, Red Color, Dot Pattern, Gray Scale,
Monoscope, Multi-Burst)
2. AC Milli Voltmeter (RMS)
3. Alignment Tape (FL6A), Blank Tape
4. DC Voltmeter
5. Oscilloscope: Dual-trace with 10:1 probe,
V-Range: 0.001~50V/Div,
F-Range: DC~AC-60MHz
6. Frequency Counter
7. Plastic Tip Driver
How to set up the option code
1. Enter the Service mode.
2. Press the [STATUS/EXIT] button on the remote
control unit. The option code appears on the display.
3. If needed, input the option code as shown below
using number buttons on the remote control unit.
ModelOption Code
14PV111(112)(415)/07000128
14PV112(415)/39000129
14PV111(415)/01000130
14PV111(415)/58000131
14PV203(460)(465)/01000158
14PV203(460)(465)/07000156
14PV203(460)(465)/39000157
14PV203(460)(465)/58000159
4. To reset the software, press [PAUSE] and [5] buttons on the remote control unit.
The option code is changed.
How to Set up the Service mode:
NOTE:
After replacing the IC202 ( Memory ) or Main CBA,
the set value in IC202 ( Memory ) will be lost. So it
is necessary to set up or adjust in the Service
mode after its replacement.
Service Mode:
1. Turn the power on. (Use main power on the TV
unit.)
2. Press [STANDBY/ON], [2], [7], [1], and [MUTE]
buttons on the remote control unit in that order
within 5 seconds.
-To cancel the service mode, press [STANDBY/ON]
button on the remote control.
1-6-9T6310EA
1. DC 105V (+B) Adjustment
2. H Adjustment
Purpose: To obtain correct operation.
Symptom of Misadjustment: The picture is dark and
unit does not operate correctly.
Test pointAdj. PointModeInput
TP503
(+B)
TP504
(GND)
TapeM. EQ.Spec.
---
Note: TP503(+B), TP504(GND), VR601 --- H.V./
Power Supply CBA
1. Connect the unit to AC Power Outlet.
2. Input a color bar signal from RF input and leave it
for at least 20 minutes.
Enter the Service mode. (See page 1-6-9.)
3. Connect DC Volt Meter to TP503(+B) and
TP504(GND).
4. Adjust VR601 so that the voltage of TP503(+B)
becomes +105±0.5V DC.
VR601---
DC Voltmeter
Plastic Tip Driver
+105±0.5V DC
Color
Bar
Purpose: To get correct horizontal position and size
of screen image.
Symptom of Misadjustment: Horizontal position and
size of screen image may not be properly displayed.
Test pointAdj. PointModeInput
R583
TapeM. EQ.Spec.
---Frequency Counter 15.625kHz±300Hz
Note: R583 --- H.V./Power Supply CBA
1. Connect Frequency Counter to R583.
2. Set the unit to the VIDEO mode and no input is
necessary. Enter the Service mode.
(See page 1-6-9.)
3. Operate the unit for at least 20 minutes.
4. Press [2] button on the remote control unit and
select H-Adj Mode.
5. Press [P+/P-] buttons on the remote control unit so
that the display will change [0] to [7.]
At this moment, choose display [0] to [7] when the
Frequency counter display is closest to
15.625kHz±300Hz.
6. Turn the power off and on again.
P+/P-
buttons
Video---
1-6-10T6310EA
3. C-Trap Adjustment
4. How to measure the standard
Purpose: To get minimum leakage of the color signal
carrier.
Symptom of Misadjustment: If C-Trap Adjustment is
incorrect, stripes will appear on the screen.
Test pointAdj. PointModeInput
J219
(B-OUT)
TapeM. EQ.Spec.
---
minimum
P+/P-
buttons
Oscilloscope
Pattern Generator
Figure
---Color Bar
200mVp-p Max.
Fig. 1
V-ENV value of Digital Studio
Picture Control
Purpose: To set the recording condition appropriate
for the recording tape.
Symptom of Misadjustment: Recording or playing
back picture quality may fall. The picture will be tinted.
1. Insert a new tape (type: TDK 180) for the DSPC
alignment into the TV/VCR.
2. Input the black raster signal from the video input
jack (VIDEO-IN).
3. Enter the Service Mode. (See page 1-6-9.)
4. To enter the DSPC mode, press [1] button on the
remote control unit. Recording starts automatically
and “DSPC” appears on the display.
TVCR
DSPC
Note: J219 (B-Out)--- Main CBA
1. Connect Oscilloscope to J219.
2. Input a color bar signal from RF input.
Enter the Service mode. (See page 1-6-9.)
3. Press [0] button on the remote control unit and
select C-TRAP Mode.
4. Press [P+/P-] buttons on the remote control unit so
that the carrier leakage B-Out (4.43MHz) value
becomes minimum on the oscilloscope.
5. Turn the power off and on again.
Fig. 2
5. Recording continues for 10 seconds in SP mode.
After that, recording starts for 10 seconds in LP
mode.
6. The tape is rewinded to the recording start point.
7. The unit enters the play mode automatically and
the V-ENV levels of each SP and LP modes are
memorized into the EEPROM.
8. "OK" appears on the screen with blueback for 5
seconds, the unit enters the stop mode, and is
gone out from the factory mode.
9. If SYNC. and CTL are none, "NG" appears on the
screen with blueback for 5 seconds, the unit ejects
the cassette and is gone out from the factory mode.
Or, also when the V-ENV level in either of the SP
and LP mode is written, "NG" appears on the
screen with blueback for 5 seconds, the unit ejects
the cassette and is gone out from the factory model
TVCRTVCR
OK
NG
Normal
1-6-11T6310EA
Abnormal
Fig. 3
5. SECAM Black Level Adjustment
6. V. Size Adjustment
Purpose: To set Black Level of the SECAM signal R-
Y/B-Y to Ref. level.
Symptom of Misadjustment: If Black Level of the
SECAM signal R-Y/B-Y is incorrect, the picture is bluish or reddish in grayscale compared with PAL signal.
Test pointAdj. PointModeInput
Pin 1 of
CN303
TapeM. EQ.Spec.
---Pattern Generator---
1. Degauss the CRT and allow CRT to operate for 20
minutes before starting the alignment.
2. Input the SECAM Gray Scale signal from video
input.
3. Enter the Service Mode. (See page 1-6-9.)
4. To enter the C/D/S mode, press [p] on the
remote control unit.
5. To select SBR (SECAM Black Level R-Y), press [6]
button on the remote control unit.
6. Press [P+/P-] buttons to adjust Y signal to the black
ref. level.
7. To select SBB (SECAM Black Level B-Y), press [7]
button on the remote control unit.
8. Press [P+/P-] buttons to adjust Y signal to the black
ref. level.
Y Signal
P+/P-
buttons
---
SECAM
Gray Scale
Purpose: To obtain correct vertical height of screen
image.
Symptom of Misadjustment: If V. Size is incorrect,
vertical height of image on the screen may not be
properly displayed.
Test pointAdj. PointModeInput
Screen
TapeM. EQ.Spec.
---Pattern Generator90±5%
1. Enter the Service mode. (See page 1-6-9.)
Press [9] button on the remote control unit and
select V-S Mode. (Press [9] button then display will
change to V-P and V-S).
2. Input monoscope pattern.
3. Press [P+/P-] buttons on the remote control unit so
that the monoscope pattern is 90±5% of display
size and the circle is round.
P+/P-
buttons
---Monoscope
7. V. Shift Adjustment
Purpose: To obtain correct vertical position of screen
image.
Symptom of Misadjustment: If V. position is incorrect, vertical position of image on the screen may not
be properly displayed.
Test pointAdj. PointModeInput
Screen
P+/P-
buttons
---Monoscope
1H
Black REF. Level
1H
1H
5mV/Div (10:1 Prove)
Fig. 4
TapeM. EQ.Spec.
---Pattern Generator90±5%
1. Enter the Service mode. (See page 1-6-9.)
Press [9] button on the remote control unit and
select V-P Mode. (Press [9] button then display will
change to V-P and V-S).
2. Input monoscope pattern.
3. Press [P+/P-] buttons on the remote control unit so
that the top and bottom of the monoscope pattern
are equal to each other.
1-6-12T6310EA
8. H. Shift Adjustment
Purpose: To obtain correct horizontal position and
size of screen image.
Symptom of Misadjustment: Horizontal position and
size of screen image may not be properly displayed.
Test pointAdj. PointModeInput
Screen
TapeM. EQ.Spec.
---Pattern Generator90±5%
1. Enter the Service mode. (See page 1-6-9.)
Press [8] button on the remote control unit and
select H-P Mode.
2. Input monoscope pattern.
3. Press [P+/P-] buttons on the remote control unit so
that the left and right side of the monoscope pattern are equal to each other.
4. Turn the power off and on again.
P+/P-
buttons
---Monoscope
9. Cut-off Adjustment
Purpose: To adjust the beam current of R, G, B, and
screen voltage.
Symptom of Misadjustment: White color may be
reddish, greenish or bluish.
Test pointAdj. PointModeInput
Screen
TapeM. EQ.Spec.
---Pattern Generator
Screen-Control
P+/P- buttons
Ext.
See Reference
Notes below
Black
Raster
Notes:
Screen Control (FBT) --- H.V./Power Supply CBA
FBT= Fly Back Transformer
Use the Remote Control Unit
1. Degauss the CRT and allow CRT to operate for 20
minutes before starting the alignment.
2. Set the screen control to minimum position. Input
the Black raster signal from RF input.
3. Enter the Service Mode. (See page 1-6-9.)
Dimmed horizontal line appears on the CRT.
4. To enter the C/D/S mode, press the [p] button
on the remote control unit.
5. To enter the CUT OFF (R) mode, press [1] button
on the remote control unit.
6. Turn the screen control up until dimmed horizontal
line appears.
7. Press the [P+/P-] buttons until the horizontal line
becomes white.
8. To enter the C/D/S mode, press the [p] button
on the remote control unit.
9. To enter the CUT OFF (G) mode, press [2] button
on the remote control unit.
10.Press the [P+/P-] buttons until the horizontal line
becomes white.
11.To enter the C/D/S mode, press the [p] button
on the remote control unit.
12.To enter the CUT OFF (B) mode, press [3] button
on the remote control unit.
13.Press the [P+/P-] buttons until the horizontal line
becomes white.
14.Turn the screen control so that the horizontal line
adjusted white looks lightly.
15.Turn the power off and on again.
Figure
PATTERN GENERATOR
EXT. INPUT
Fig. 5
1-6-13T6310EA
10. White Balance Adjustment
11. Sub-Brightness Adjustment
Purpose: To mix red, green and blue beams correctly
for pure white.
Symptom of Misadjustment: White becomes bluish
or reddish.
Test pointAdj. PointModeInput
Screen
TapeM. EQ.Spec.
---
Screen-Control
P+/P- buttons
Pattern Generator
Color analyzer
Figure
Color Ajalyzer
RF
See below
White Ras-
ter (APL
100%)
Fig. 6
Purpose: To get proper brightness.
Symptom of Misadjustment: If Sub-Brightness is
incorrect, proper brightness cannot be obtained by
adjusting the Brightness Control.
Test pointAdj. PointModeInput
Screen
TapeM. EQ.Spec.
---
White
P+/P-
buttons
Pattern
Generator
Figure
---SYMPTE
See below
Black
This bar
ABC
(A) just
visible
Note: Use remote control unit
1. Operate the unit more than 20 minutes.
2. Face the unit to east. Degauss the CRT using Degaussing Coil.
3. Input the White Raster (APL 100%).
4. Set the color analyzer to the CHROMA mode and
after zero point calibration, bring the optical receptor to the center on the tube surface (CRT).
5. Enter the Service mode. Press [p] button on
the remote control.
6. Press [4] button on the remote control unit for Red
adjustment. Press [5] button on the remote control
unit for Blue adjustment.
7. In each color mode, Press [P+/P-] buttons to adjust
the values of color.
8. Adjusting Red and Blue color so that the temperature becomes 8500K (x : 290 / y : 300) ±3%.
9. At this time, Re-check that Horizontal line is white.
If not, Re-adjust Cut-off Adjustment until the Horizontal Line becomes pure white.
10. Turn off and on again to return to normal mode. Receive APL 100% white signal and Check Chroma
temperatures become 8500K (x : 290 / y : 300) ±3%.
Note: Confirm that Cut Off Adj. is correct after this
adjustment, and attempt Cut Off Adj. if needed.
Fig. 7
Note: Bar (A) in Fig. 7 --- 0 IRE
1. Enter the Service Mode. (See page 1-6-9.)
Then input SYMPTE signal from RF input.
2. Press MENU button. (Each time MENU button is
pressed, display will change BRT, CNT, COL, TNT,
and SHP in that order.) Select BRT and press [P+/
P-] buttons so that the bar (A) in Fig. 7 is just visible.
3. Turn the power off and on again.
1-6-14T6310EA
12. Setting for CONTRAST,
COLOR, TINT and SHARP
Data Values
General
1. Enter the Service mode. (See page 1-6-9)
2. Press MENU button. (Each time MENU button is
pressed, display will change BRT, CNT, COL,
TNT, and SHP in that order.)
CONTRAST (CNT)
1. Press "MENU" button on the remote control unit.
Then select CNT display.
2. Press [P+/P-] buttons on the remote control unit so
that the value of "CONTRAST" (CNT) becomes 85.
COLOR (COL)
1. Press "MENU" button on the remote control unit.
Then select "COLOR" (CLR) display.
2. Press [P+/P-] buttons on the remote control unit so
that the value of "COLOR" (COL) becomes 55.
TINT (TNT)
1. Press "MENU" button on the remote control unit.
Then select "TINT" (TNT) display.
2. Press [P+/P-] buttons on the remote control unit so
that the value of "TINT" (TNT) becomes 57.
SHARP (SHP)
1. Press "MENU" button on the remote control unit.
Then select "SHARP" (SHP) display.
2. Press [P+/P-] buttons on the remote control unit
and select "1."
13. Focus Adjustment
Purpose: Set the optimum Focus.
Symptom of Misadjustment: If Focus Adjustment is
incorrect, blurred images are shown on the display.
Test pointAdj. PointModeInput
ScreenFocus Control---Monoscope
TapeM. EQ.Spec.
---Pattern GeneratorSee below.
Note: Focus VR (FBT) --- H.V./Power Supply CBA
FBT= Fly Back Transformer
1. Operate the unit more than 30 minutes.
2. Face the unit to the East and degauss the CRT
using a Degaussing Coil.
3. Input the monoscope pattern.
4. Adjust the Focus Control on the FBT to obtain clear
picture.
1-6-15T6310EA
14. Head Switching Position Adjustment
Purpose: Determine the Head Switching Point during
Playback.
Symptom of Misadjustment: May cause Head
Switching Noise or Vertical Jitter in the picture.
Note: Unit reads Head Switching Position automatically and displays it on the screen (Upper Left Corner).
1. Enter the Service Mode. (See page 1-6-9.)
Then press the number [5] button on the remote
control unit.
2. Playback the test tape (FL6A).
3. The Head Switching position will display on the
screen; if adjustment is necessary follow step 4.
6.5H(412.7µs) is preferable.
4. Press [P+/P-] buttons on the remote control unit if
necessary. The value will be changed in 0.5H steps
up or down. Adjustable range is up to 9.5H. If the
value is beyond adjustable range, the display will
change as:
Lower out of range: 0.0H
Upper out of range: -.-H
5. Turn the power off and on again.
1-6-16T6310EA
Adjustment Points and Test Points
H.V./Power Supply CBA Top View
Main CBA Top View
Focus-control
(Upper side)
R583
(H Adjustment)
VR601
+B ADJ
Screen-control
(Lower side)
TP504
GND
TP503
+B
TP002
RF-SW
TP001
IC202
CTL
TP003
V-OUT
TP004
TP007
CPB
A-OUT
J219
B-OUT
Pin 1 of CN303
(SECAM Black Level Adjustment)
TEST POINT INFORMATION
: Indicates a test point with a jumper wire across a hole in the PCB.
TEST POINTS NOT USED IN ELECTRICAL ADJUSTMENTS
Test Point
TP001
TP002
TP004
TP503
TP504
Mechanical Alignment Procedures
Mechanical Alignment Procedures
Mechanical Alignment Procedures
Electrical Adjustment Instructions
Electrical Adjustment Instructions
Used in:Page No.
15
2-3-3
2-3-3, 2-3-4
2-3-3, 2-3-4
1-6-1
1-6-1
1-6-17T6310EA
Servo/System Control Block Diagram
(DECK ASSEMBLY)
AC HEAD ASSEMBLY
CL402
CONTROL
HEAD
CYLINDER ASSEMBLY
PG
SENSOR
DRUM
MOTOR
M
LOADING
MOTOR
M
2CTL(+)
1CTL(-)
NOTE FOR WIRE CONNECTORS:
1. PREFIX SYMBOL "CN" MEANS CONNECTOR.
(CAN DISCONNECT AND RECONNECT.)
2. PREFIX SYMBOL "CL" MEANS WIRE-SOLDER
HOLES OF THE PCB.
(WIRE IS SOLDERED DIRECTLY.)
:INDICATES A TEST POINT WITH A JUMPER WIRE ACROSS A HOLE IN THE PCB.
:USED TO INDICATE A TEST POINT WITH A COMPONENT LEAD ON FOIL SIDE.
:USED TO INDICATE A TEST POINT WITH NO TEST PIN.
:USED TO INDICATE A TEST POINT WITH A TEST PIN.
1. PREFIX SYMBOL "CN" MEANS CONNECTOR.
(CAN DISCONNECT AND RECONNECT.)
2. PREFIX SYMBOL "CL" MEANS WIRE-SOLDER
HOLES OF THE PCB.
(WIRE IS SOLDERED DIRECTLY.)
C-VIDEO
IC401
(VIDEO/AUDIO SIGNAL PROCESS)
WF4
Q752
BUFFER
Q751
BUFFER
WF5
TP003
V-OUT
Q401
BUFFER
Q402
BUFFER
48
52
54
56
61
63
TUNER1
SCART
SCART
LINE
PB/EE
MUTE
TUNER1
PB/EE
MUTE
TEST POINT INFORMATION
:INDICATES A TEST POINT WITH A JUMPER WIRE ACROSS A HOLE IN THE PCB.
:USED TO INDICATE A TEST POINT WITH A COMPONENT LEAD ON FOIL SIDE.
:USED TO INDICATE A TEST POINT WITH NO TEST PIN.
:USED TO INDICATE A TEST POINT WITH A TEST PIN.
1. PREFIX SYMBOL "CN" MEANS CONNECTOR.
(CAN DISCONNECT AND RECONNECT.)
" " = SMD
2. PREFIX SYMBOL "CL" MEANS WIRE-SOLDER
HOLES OF THE PCB.
(WIRE IS SOLDERED DIRECTLY.)
TEST POINT INFORMATION
:INDICATES A TEST POINT WITH A JUMPER WIRE ACROSS A HOLE IN THE PCB.
:USED TO INDICATE A TEST POINT WITH A COMPONENT LEAD ON FOIL SIDE.
:USED TO INDICATE A TEST POINT WITH NO TEST PIN.
:USED TO INDICATE A TEST POINT WITH A TEST PIN.
PB-AUDIO SIGNALREC-AUDIO SIGNALMode : SP/REC
TU001
JK702
A-IN
A-IN(R)
A-IN(L)
A-OUT(R)
A-OUT(L)
TU-AUDIO
JK751
2
6
1
3
21
Q758
IC751 (SW)
1
2
5
3
13
12
SW CTL
10119
SCART-MUTE
15
4
14
SCART-H
EXT-L
TO SERVO
/SYSTEM
CONTROL
BLOCK
WF7
52
53
54
(VIDEO/AUDIO/CHROMA/DEFLECTION/IF)
IC301
TUNER1
LINE
AUDIO
MUTE
+5V
ATT
50
IC401
(AUDIO SIGNAL PROCESS)
TUNER1
13
LINE
17
PB-ON
5
6
EQ
AMP
SP/LP-ON
MAIN CBA
IC801 (AMP)
7
WF9
7
OUTPUT
AMP
MUTE
5
98
1
SP-MUTE1
(FROM PIN 44 OF IC201)
INV
ATT
CN801
SP
SP-GND2
R
P
ALC
DET
ALC
JK801
HEADPHONE JACK
1
LINE
AMP
SP801
SPEAKER
MUTE
12
11
TP007
A-OUT
WF8
(DECK ASSEMBLY)
AUDIO
HEAD
AUDIO
ERASE
HEAD
ACE HEAD ASSEMBLY
FULL
ERASE
HEAD
FE HEAD
REC-ON
71
A-MUTE-H
SDATO SERVO/SYSTEM
SCL
CONTROL BLOCK
CL402
3 A-PB/REC
4 A-COM
6 AE-H
5 FE-H
CL403
1 FE-H
2 FE-H-GND
Q852
Q853
BIAS
OSC
Q851
Q854(PB=ON)
Q856
Q855(PB=ON)
1
2
SWITCHING
D-REC-OFF
+5V
AUTO
BIAS
3
100
AUDIO HD-SW
REC
AMP
SERIAL
DECODER
CONTROL
16
68 69
1-7-171-7-18T6310BLA
Chroma Block Diagram
" " = SMD
K,L,O,P,S,T,W,X
(TELETEXT DECODER)
IC901
ADC/
DATA SLICER
SYNC SW
I2C I/F
TELETEXT
DECODER
OSC/CLOCK
GENERATOR
TEXT CBA
FROM/TO
SERVO/SYSTEM
CONTROL BLOCK
11
20
19
3
2
27
28
29
30
41
42
I2C-OPEN
BUFFER
Q904
BUFFER
Q901
X901
13.875
MHz
OSC
CN303 is used for
adjustment at factory
SCL
SDA
NOTE FOR WIRE CONNECTORS:
1. PREFIX SYMBOL "CN" MEANS CONNECTOR.
(CAN DISCONNECT AND RECONNECT.)
2. PREFIX SYMBOL "CL" MEANS WIRE-SOLDER
HOLES OF THE PCB.
(WIRE IS SOLDERED DIRECTLY.)
CN901CN751
77Y-SW-OUT
22SYNC
44SDA
33SCL
CN752CN902
66OSD-BLK
33OSD-B
44OSD-G
22OSD-R
(NO CONNECTION)
INT.MONITOR
I2C-OPEN2
SDA4
SCL5
CN303
1
TEST POINT INFORMATION
:INDICATES A TEST POINT WITH A JUMPER WIRE ACROSS A HOLE IN THE PCB.
:USED TO INDICATE A TEST POINT WITH A COMPONENT LEAD ON FOIL SIDE.
:USED TO INDICATE A TEST POINT WITH NO TEST PIN.
:USED TO INDICATE A TEST POINT WITH A TEST PIN.
1. PREFIX SYMBOL "CN" MEANS CONNECTOR.
(CAN DISCONNECT AND RECONNECT.)
" " = SMD
2. PREFIX SYMBOL "CL" MEANS WIRE-SOLDER
HOLES OF THE PCB.
(WIRE IS SOLDERED DIRECTLY.)
TEST POINT INFORMATION
:INDICATES A TEST POINT WITH A JUMPER WIRE ACROSS A HOLE IN THE PCB.
:USED TO INDICATE A TEST POINT WITH A COMPONENT LEAD ON FOIL SIDE.
:USED TO INDICATE A TEST POINT WITH NO TEST PIN.
:USED TO INDICATE A TEST POINT WITH A TEST PIN.
REC VIDEO SIGNALPB VIDEO SIGNAL
Mode : SP/REC
FROM
POWER SUPPLY BLOCK
2
FROM/TO
CHROMA BLOCK
CL302A
TO VIDEO BLOCK
CN701
FROM CHROMA
BLOCK CL301A
3
6
4
7
CN505
1
2
3
4
4
3
2
H.V./POWER SUPPLY CBA
+B
DEF+B
JUNCTION-B
CBA
CN302CL302B
CL505B
JUNCTION-D
CBA
CN301CL301B
JUNCTION-C
CBA
22AFC
33H-DRIVE
66ACL
44V-RAMP-NF
77V-DRIVE
44RED
33GREEN
22BLUE
CN503
CL505A
CN504
Q572
H.DRIVE
WF12
Q571
H.OUTPUT
T572
1
5
3
4
T571 F.B.T.
Q501
RED AMP
10
IC551 (V-DEFLECTION CONTROL)
THERMAL
7
AMP
1
6
FOCUS VR
HV
F
S
11
8
7
9
6
SCREEN VR
Q502
GREEN AMP
PROTECTION
PUMP
UP
VCC
2
3
ANODE
FOCUS
SCREEN
HEATER11
P-ON+160V33
WF15WF14
5
CL501BCL501A
BLUE AMP
Q503
WF16
WF13
CN571
L551
DEFLECTION-YOKE
5
4
3
1
JK501
CN501
VDRIVE
HDRIVE
FOCUS
SCREEN
GND
GND
ANODE
V501
R
CRT
G
B
HEATER
CRT CBA
1-7-221-7-21
T6310BLCRT
Power Supply Block Diagram
CAUTION !
Fixed voltage power supply circuit is used in this unit.
If Main Fuse (F601) is blown, check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
4A/125V
CAUTION
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD,
REPLACE ONLY WITH THE SAME TYPE FUSE.
ATTENTION : POUR UNE PROTECTION CONTINUE LES RISQES
D'INCELE N'UTILISER QUE DES FUSIBLE DE MEMO TYPE.
RISK OF FIRE-REPLACE FUSE AS MARKED.
"This symbol means fast operating fuse."
"Ce symbole reprèsente un fusible à fusion rapide."
NOTE :
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.