Pentax TH8321U1097 Operating Manual

Operating Manual
VisionPRO® TH8000 Series - TH8321U1097
Touchscreen Programmable Thermostat
69-2400EFS-05
BE CAREFUL! Never use sharp instruments, such as a pencil or pen, to press touchscreen keys. To prevent damage to the thermostat, always press keys with your fingertip.
This manual covers the following models
ENGLISH
This thermostat contains a Lithium battery which may contain Perchlorate material. Perchlorate Material—special handling may apply, See www.dtsc.ca.gov/hazardouswaste/perchlorate
TH8321U1097: For up to 3 Heat/2 Cool systems with indoor air quality control
M29343
For assistance with this product please visit http://yourhome.honeywell.com
or call Honeywell Customer Care toll-free at 1-800-468-1502
Read and save these instructions.
US Patent No. 6595430, D509151 and other patents pending.
Copyright © 2013 Honey well International Inc. All rights reser ved.
® U.S. Registered Trademark.
Table of contents
VisionPRO® TH8000 Series
About your new thermostat
Thermostat features ............................... 2
Programming at a glance ....................... 3
Quick reference to controls .................... 4
Quick reference to status display ........... 5
Programming & Operation
Clock setting ........................................... 6
Fan setting .............................................. 7
System setting ........................................ 8
Using program schedules ....................... 9
Program schedule overrides ................ 12
Vacation hold ........................................ 14
Special features .................................... 15
Screen lock ........................................... 16
Screen cleaning .................................... 17
Humidity display & control .................... 18
Appendices
Battery replacement ............................. 22
Advanced functions .............................. 23
In case of difficulty ................................ 30
Optional remote sensors ...................... 32
Limited warranty ................................... 33
This thermostat is ready to go!
Your new thermostat is pre­programmed and ready to go. See page 3 to check settings.
CAUTION: EQUIPMENT DAMAGE HAZARD. To prevent possible
compressor damage, do not operate cooling system when outdoor
temperature is below 50˚F (10˚C).
1
69-2400EFS—05
ENGLISH
Operating Manual
About your new thermostat
Congratulations! You’ve just purchased the world’s most advanced, easy-to-use thermo­stat. It has been designed to give you many years of reliable service and touchscreen climate control.
ENGLISH
Features
• 7-day program schedules maximize comfort and economy.
• Armchair programming: Just pull thermostat from the wall to set schedules.
• One-touch temp control overrides program schedule at any time.
• Precise comfort control keeps temperature within 1°F of the level you set.
• Change/check reminders let you know when to service or replace filters, batteries
and other critical components.
• Large touchscreen display with backlight is easy to read—even in the dark.
• Accommodates optional outdoor or indoor remote sensors.
• Controls humidification, dehumidification, or ventilation.
69-2400EFS—05
2
VisionPRO® TH8000 Series
About your new thermostat
This thermostat is ready to go!
Your new thermostat is pre-programmed and ready to go. Just set the time and day. Then check the settings below and change if needed:
1. Set clock ......................................................................................................... See page 6
2. Select fan setting: Preset to Auto ................................................................. See page 7
3. Select system setting: Preset to Heat .......................................................... See page 8
4. Program schedules: Preset to energy-saving levels
while you’re at work or asleep (assumes you wake at 6 am, leave at 8 am, return at 6 pm
and go to bed at 10 pm) ......................................................................... See pages 10-13
ONE-TOUCH TEMP CONTROL: You can override the program schedule at any time, and
manually adjust the temperature (see pages 12-14).
ENGLISH
3
69-2400EFS—05
Operating Manual
Quick reference to controls
Press day(s) to set program schedule (see page 11)
Press to select fan
operation (see page 7)
ENGLISH
Press to select system
type (see page 8)
Press to set program
schedule (see page 11)
Press to override program schedule
(see pages 12-14)
69-2400EFS—05
TUE WED THU FRI SAT SUN
MON
OK TO PICK MULTIPLE DAYS
FAN
Inside
AUTO
70
SYSTEM
HEAT
SCHED HOLD CLOCK SCREEN MORE
6:01
AM
Press to set clock
(see page 6)
4
Set To
70
Following Schedule
Press to adjust temperature settings
(see pages 11-14)
Press for more options
(select models only)
M29344
Press to lock keypad for 30 seconds to clean screen
(see page 17)
VisionPRO® TH8000 Series
Quick reference to status display
Current inside temperature Current day of week Temperature setting
WED
FAN
Fan setting
System setting
Current time
Inside
AUTO
70
SYSTEM
HEAT
6:01
SCHEDHOLD CLOCKSCREEN MORE
Other display messages:
Cool On: Cooling system is activated
Heat On: Heating system is activated
Aux Heat On: Auxiliary heating system is activated
Set To
70
Following Schedule
Recovery
AM
M29345
Program schedule on
(does not display when off)
Adaptive Intelligent Recovery in effect
(see page 15)
ENGLISH
5
69-2400EFS—05
Operating Manual
Clock setting
Press CLOCK
AM
ENGLISH
6:01
SCHED HOLD CLOCK SCREEN MORE
Adjust time, then press DONE
6:02
DONE CANCEL
69-2400EFS—05
AM
To set the current time display, press CLOCK, then press s or t to adjust the time. Press and hold s or t to advance the time more quickly.
Press DONE to save & exit (or press CANCEL to
exit without changing the time).
M29346
Note: The real-time clock should never require adjustment since it automatically updates for daylight savings time, and stores all date/time information.
Note: To change the current week day display, see page 24.
M29347
6
Fan setting
VisionPRO® TH8000 Series
WED
FAN
Inside
AUTO
70
SYSTEM
HEAT
6:01
SCHEDHOLDCLOCK SCREEN MORE
Note: If a fan schedule is programmed, “Auto” will run the fan schedule.
Set To
AM
Press FAN
70
Following Schedule
M29348
Press FAN to select fan operation, then press DONE.
On: Fan is always on.
Auto: Fan runs only when the heating or
cooling system is on.
Circ: Fan runs randomly, about 35% of the
time, not counting any run time with the heating or cooling system.
You can press FAN to override the fan settings you’ve programmed for different time periods (see page 11). If you select On or Circ, the set­ting you select will remain active until you press
FAN again to select Auto (see page 31 for more information).
7
69-2400EFS—05
ENGLISH
Operating Manual
System setting
FAN
Inside
AUTO
ENGLISH
SYSTEM
HEAT
69-2400EFS—05
WED
Set To
70
AM
6:01
SCHED HOLD CLOCKSCREEN MORE
70
Following
Schedule
M29349
Press the SYSTEM button to select, then press DONE.
Heat: Thermostat controls only the heating
system.
Cool: Thermostat controls only the cooling
system.
Off: Heating and cooling systems are off.
Auto: Thermostat automatically selects
heating or cooling depending on the indoor temperature.**
Em Heat (only for heat pumps with
auxiliary heat): Thermostat controls Emergency and Auxiliary Heat.
Compressor is locked out.**
** Select models only
8
VisionPRO® TH8000 Series
Save money by setting program schedules
It’s easy to program your system for maximum energy savings. You can program four time
periods each day, with different settings for weekdays and weekends.
WAKE
6:00 am
°
70
LEAVE
8:00 am
°
62
RETURN
6:00 pm
°
70
SLEEP
10:00 pm
°
62
Set to the time you awaken and the temperature you want during the morning, until you leave for the day.
Set to the time you leave home and the temperature you
want while you are away (usually an energy-saving level).
Set to the time you return home and the temperature you want during the evening, until bedtime.
Set to the time you go to bed and the temperature you want
overnight (usually an energy-saving level).
9
69-2400EFS—05
ENGLISH
Operating Manual
Energy saving settings for maximum cost savings
This thermostat is pre-set to use energy saving program settings. We recommend these
settings, since they can reduce your heating/cooling expenses. (See next page to adjust times and temperatures of each time period.)
ENGLISH
Cool (Mon-Fri)Heat (Mon-Fri) Heat (Sat-Sun) Cool (Sat-Sun)
Wake
(6:00 am)
Leave
(8:00 am)
Return
(6:00 pm)
Sleep
(10:00 pm)
70 62 70 62
°
°
°
°
78 85
78
82
°
°
°
[Or cancel period]
°
°
70
°
62
[Or cancel period]
°
70
°
62
°
78
°
85
[Or cancel period]
°
78
[Or cancel period]
°
82
69-2400EFS—05
10
To adjust program schedules
VisionPRO® TH8000 Series
Press SCHED
SCHED HOLD CLOCKSCREEN MORE
70
M29350
M29351
HEAT
COOL
M29352
Press EDIT
DONE WAKE LEAV ERETURN SLEEPEDIT CANCEL
Select day(s) Set heat/cool levels
MON
TUE WED THU FRI SATSUN
OK TO PICK MULTIPLE DAYS
FAN
AUTO
CANCEL
PERIOD
6:00
DONE WAKE LEAV ERETURN SLEEP CANCEL
AM
78
Set time for program period to start
1. Press SCHED, then EDIT.
2. Press day buttons (MON-SUN) to select day(s).
3. Press s or t to set Wake time for selected
day(s).
4. Press s or t to set Heat and Cool temperature for this time period.
5. Press other time periods (LEAVE, RETURN, SLEEP) to set time and temperatures for each.
6. Press DONE to save & exit (or press CANCEL to exit without saving changes).
Note: You can press CANCEL PERIOD to eliminate any unwanted time period.
Note: Press FAN to customize fan settings for any time
period (see page 7).
11
69-2400EFS—05
ENGLISH
Operating Manual
Program schedule override (temporary)
FAN
ENGLISH
AUTO
SYSTEM
HEAT
Inside
Hold Temperature
8:00
SCHEDHOLDCLOCK SCREEN MORE
Press to set timer
69-2400EFS—05
Adjust temperature
WED
Set To
70
Until
AM
Press CANCEL (or SCHED) to resume program schedule
73
Heat On
CANCEL
M29353
Press s or t to immediately adjust the temper­ature. This will temporarily override the tempera­ture setting for the current time period.
The new temperature will be maintained only
until the time you set. When the timer expires,
the program schedule will resume and set the temperature to the level you’ve programmed for the current time period.
To cancel the temporary setting at any time, press CANCEL (or SCHED). The program schedule will resume.
12
Program schedule override (permanent)
VisionPRO® TH8000 Series
Press HOLD Adjust temperature
WED
FAN
Inside
AUTO
70
SYSTEM
HEAT
8:00
Permanent
Hold
SCHED HOLD CLOCKSCREEN MORE
Press CANCEL (or SCHED) to resume program schedule
Set To
73
Heat On
AM
CANCEL
M29354
Press HOLD to permanently adjust the temperature. This will turn off the program schedule.
Whatever temperature you set will be maintained 24 hours a day until you manually change it or press CANCEL (or SCHED) to cancel “Hold” and resume the program schedule.
13
69-2400EFS—05
ENGLISH
Operating Manual
Vacation hold
1. Set temperature
FAN
Inside
AUTO
70
ENGLISH
SYSTEM
Hold Temperature
HEAT
Until
6:00
SCHEDHOLDCLOCK SCREEN MORE
2. Press to set time for
3. Press HOLD twice
SYSTEM
Hold Temperature
HEAT
Until
14
SCHED HOLD CLOCKSCREEN MORE
4. Press to select number of days
69-2400EFS—05
Set To
AM
schedule to resume
DAYS
55
CANCEL
M29355
CANCEL
M29356
This feature can suspend the program schedule
for extended periods of time.
Press s or t to set the temperature you want, then press s or t to set the time of day you want the schedule to resume when you return. Press HOLD twice, then press s or t to select the number of days.
Whatever temperature you set will be maintained 24 hours a day for the number of days you select. After this number of days have elapsed, the previously programmed schedule will resume at the time you set.
If you return earlier than expected, press CANCEL (or SCHED) to cancel “Hold” and resume the pro-
gram schedule.
14
VisionPRO® TH8000 Series
Special features
Auto Changeover: When set to Auto, the thermostat automatically selects heating or
cooling depending on the indoor temperature. Adaptive Intelligent Recovery: This feature allows the thermostat to “learn” how long
the furnace and air conditioner take to reach programmed temperature settings, so the
temperature is reached at the time you set. For example: Set the Wake time to 6 am, and the temperature to 70°. The heat will come on before 6 am, so the temperature is 70° by
the time you wake at 6. The message “Recovery” is displayed when the system is acti­vated before a scheduled time period.
Compressor Protection: This feature forces the compressor to wait a few minutes before restarting, to prevent equipment damage. During the wait time, the message “Wait” is dis­played on screen.
Away Dehumidification Mode: Your system may be programmed to control humidity while your house is vacant during the humid season. Before you leave the house, press the HOLD button three times to activate this feature. This will control temperature and
humidity to help protect your house and possessions while you are away. (If this feature does not work, contact your installer.)
ENGLISH
15
69-2400EFS—05
Operating Manual
Screen lock
WED
FAN
Inside
AUTO
ENGLISH
SYSTEM
70
HEAT
6:00
SCHED HOLD CLOCK SCREEN MORE
See advanced function 0670 (page 29) for screen lock options
69-2400EFS—05
To prevent tampering, the screen can be partially
SCREEN LOCKED
Set To
70
Following
Schedule
or fully locked. When partially locked, the screen displays
SCREEN LOCKED for several seconds if a locked key is pressed. To unlock the screen, press any unlocked key while SCREEN LOCKED appears on
PM
the screen. When the screen is fully locked, no keys function.
To lock or unlock the screen, see advanced func-
M29357
tion 0670 on page 29.
16
Screen cleaning
VisionPRO® TH8000 Series
Press SCREEN
30
PM
OK TO CLEAN SCREEN
6:00
SCHEDHOLDCLOCK SCREEN MORE
Screen lock timer (30 seconds)
M29358
M29359
Press SCREEN to lock the screen for cleaning. The screen will remain locked for 30 seconds so you can clean the screen without changing any settings.
After 30 seconds, press DONE to resume normal operation, or press SCREEN again if you require more time for cleaning.
Note: Do not spray any liquid directly on the thermostat. Spray liquids onto a cloth, then use the damp cloth to clean the screen. Use water or household glass cleaner. Avoid abrasive cleansers.
17
69-2400EFS—05
ENGLISH
Operating Manual
Humidification control
Set Frost Control & humidity level
ENGLISH
Inside
32
Auto
DONE
Press to save
& exit
69-2400EFS—05
Press to select Auto or Off
55
5
FROST
DEHUMIDIFIER
CANCEL
MCR29720
Press MORE until the humidifier screen is dis­played, then press s or t to set the humidity and Frost Control level.
When using Frost Protection, if frost/condensa­tion appears on windows, lower the frost setting. Wait at least 1 day before adjusting the frost level again. Once frost no longer appears, the thermo-
stat will control humidity to the maximum level
without frosting or fogging windows and without further adjustment.
Press DONE to save and exit, or press CANCEL to
exit without saving changes.
Note: Humidification control not available on all models. Note: If you do not have an outdoor temperature
sensor, the Frost Control level will not be displayed.
18
Dehumidification control
VisionPRO® TH8000 Series
Press to select Auto or Off
Inside
Press to set desired humidity
73
DEHUMIDIFIER
AUTO
DONE CANCEL
Press to save & exit
55
MCR29721
Press MORE until the dehumidifier screen is displayed, then press s or t to set the desired
humidity level and operation (Auto or Off).
If installed to control a dehumidifier, the thermo­stat can activate it as needed to reduce humidity.
If you don’t have a dehumidifier, the thermostat activates the air conditioner to reduce humidity
(may cool as much as 3°F lower than your tem­perature setting).
Press DONE to save and exit, or press CANCEL to exit without saving changes.
Note: Dehumidification control not available on all models.
19
69-2400EFS—05
ENGLISH
Operating Manual
Ventilation control
Press to set ventilation timer
ENGLISH
AUTO
DONE CANCEL
Press to save & exit
69-2400EFS—05
VENT
40
Minutes
MCR29722
You can ventilate your home at any time:
Press MORE until the ventilation screen is dis­played, then press s or t to set the ventilation timer. You can set the timer to ventilate from 20 to 180 minutes, in 20-minute increments. To turn off the ventilator, select 0.
Press DONE to save and exit, or press CANCEL to
exit without saving changes.
If programmed for auto-ventilation by the install­er, the thermostat will ventilate your home as needed.
Auto/Off will turn off/on the automatic ventilation only. Ventilation can still be requested by using the timer when set to Off.
Note: Ventilation control not available on all models.
20
Humidity level display
VisionPRO® TH8000 Series
WED
FAN
Inside
AUTO
70
SYSTEM
HEAT
6:00
SCHED HOLD CLOCK SCREEN MORE
Indoor humidity level
PM
Set To
70
Following
Schedule
43
Humidity
M29360
Select models can display the current indoor humidity level.
(If an optional outdoor sensor is installed, the
outdoor temperature is shown instead of the humidity level. Press MORE to display the humid-
ity level.)
21
69-2400EFS—05
ENGLISH
Operating Manual
About your new thermostat
Battery replacement
Grasp thermostat and pull to remove fom wallplate
ENGLISH
Insert 3 fresh AAA alkaline batteries
69-2400EFS—05
Batteries are optional (to provide backup power)
if your thermostat was wired to run on AC power when installed.
Install fresh batteries immediately when the LO BATT warning begins flashing. The warning flash­es about 30 days before batteries are depleted.
Even if the warning does not appear, you should replace batteries once a year, or before leaving home for more than a month.
M29363
M29364
22
About your new thermostat
Advanced functions
VisionPRO® TH8000 Series
1. Press SYSTEM.
TUE
FAN
Inside
AUTO
70
SYSTEM
HEAT
6:01
SCHED HOLD
M29365
2. Press and hold blank center key until the display changes.
AM
3. Change settings as
required (see pages 24-29).
4. Press DONE to exit & save changes.
23
SYSTEM
HEAT
DONE CANCEL
Function Setting
DONE
Press s/t to select function
6:01
0120
AM
20
Press s/t to change setting
69-2400EFS—05
ENGLISH
M29366
Operating Manual
About your new thermostat
Advanced functions
Year setting (first two digits)
Function
0120
Options: 20 = Ye ar 20xx
ENGLISH
Press s/t to change the first two digits of the year:
21 = Year 21xx
Year setting (second two digits)
Function
0130
Options: 01 - 99 (i.e., 2001 - 2099)
Press s/t to change the last two digits of the year:
Month setting
Function
0140
Options: 1 - 12 (i.e., January - December)
Press s/t to change the current month:
Date setting
Function
0150
Options: 1 - 31
Press s/t to change the current date:
69-2400EFS—05
24
Advanced functions
Program schedule on/off
Function
0160
Options: 0 Program schedule is off. Thermostat is non-programmable.
Restore energy saving schedule
Function
0165
Options: 0 Continue using programmed schedule.
Temperature format (°F/°C)
Function
0320
Options: 0 Fahrenheit
Press s/t to turn the program schedule on or off:
4 Program schedule is on (7-day programmable).
Press s/t to turn the energy saving schedule on or off:
1 Restore thermostat program to energy saving settings.
Press s/t to set the temperature display format:
1 Celsius
VisionPRO® TH8000 Series
ENGLISH
25
69-2400EFS—05
Operating Manual
About your new thermostat
Advanced functions
Daylight savings time on/off
Function
0330
Options: 0 Off: No adjustment for daylight savings time
ENGLISH
The thermostat is pre-programmed to automatically adjust to daylight savings time. Press s/t to select an option:
2 On: Auto-change to daylight savings time (2007 and beyond, for areas that use
the new 2007 DST calendar)
69-2400EFS—05
26
Advanced functions
Furnace filter change reminder
Function
0500
Options: 0 Off (no reminder to change furnace filter)
This feature displays an alert to remind you to change the furnace filter. Press s/t to set the desired reminder interval:
1 Reminder after 10-day run time (about 1 month) 2 Reminder after 30-day run time (about 3 months) 3 Reminder after 60-day run time (about 6 months) 4 Reminder after 90-day run time (about 9 months) 5 Reminder after 120-day run time (about 1 year) 6 Reminder after 180-day run time (about 1.5 years) 7 Reminder after 270-day run time (about 2 years) 8 Reminder after 365-day run time (about 3 years) 9 Reminder after 30 calendar days 10 Reminder after 60 calendar days 11 Reminder after 90 calendar days 12 Reminder after 120 calendar days 13 Reminder after 180 calendar days 14 Reminder after 365 calendar days
VisionPRO® TH8000 Series
Note: Press RESET to cancel the alert
ENGLISH
27
69-2400EFS—05
Operating Manual
Advanced functions
Humidifier pad change reminder
Function
0510
Options: 0 Off (no reminder to change humidifier pad)
ENGLISH
UV lamp change reminder
Function
0520
Options: 0 Off (no reminder to change UV lamp)
Adaptive Intelligent Recovery
Function
0530
Options: 0 Off
This feature displays an alert to remind you to change the humidifier pad. Press s/t to set the desired interval:
1 Reminder after 3 months 2 Reminder after 6 months 3 Reminder after 1 year
This feature displays an alert to remind you to change the ultraviolet lamp. Press s/t to set the desired interval:
1 Reminder after 1 year 2 Reminder after 2 years
Press s/t to turn on or off Adaptive Intelligent Recovery (Early Start):
1 On
Note: Press RESET to cancel the alert
Note: Press RESET to cancel the alert
69-2400EFS—05
28
Loading...
+ 78 hidden pages