THP2400A1019
Cover Plate Assembly
INSTALLATION GUIDE
Use the THP2400A1019 cover plate assembly with the RedLINK™ VisionPRO® thermostats.
Use the THP2400A1019 cover plate assembly to cover marks on the wall or to mount the thermostat to a 2 in. x 4 in. electrical box.
The THP2400A1019 cover plate assembly contains one cover plate, one bracket, two #6-32 x 5/8 flat head screws and two #6-32 x 1/4 pan head screws. See Fig. 1.
6-5/32
(156)
25/32
(20)
5-3/4
(146)
1-1/2
(38)
LEVEL |
LEVEL |
TWO #6-32 X 5/8 FLAT HEAD SCREWS |
|
TWO #6-32 X 1/4 PAN HEAD SCREWS |
BRACKET |
|
M34258 |
Fig. 1. THP2400A1019 cover plate assembly.
1.Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition.
2.Check ratings given in the instructions and on the product to make sure the product is suitable for your application.
3.Installer must be a trained, experienced service technician.
4.After installation is complete, check out product operation as provided in these instructions.
69-2762EFS-01
THP2400A1019 COVER PLATE ASSEMBLY
CAUTION
Electrical Hazard.
Can cause electrical shock or equipment damage.
Disconnect power before beginning installation.
Mount Cover Plate Directly to Wall (See Fig. 2)
1.Pull the wires through the wire hole on the cover plate and wall plate.
2.Position the cover plate and wall plate on the wall with the arrows pointing up. Level the wall plate for appearance only.
3.Use a pencil to mark the mounting holes for your thermostat.
4.Remove the cover plate and wall plate from the wall and drill two 3/16-in. holes in the wall (if drywall) as marked. For firmer material such as plaster, drill two 7/32-in. holes. Tap the wall anchors (provided with the thermostat) into the holes, until the anchor collar touches the wall.
5.Pull the wires through the wire hole on the cover plate and wall plate. Position the cover plate and wall plate on the wall anchors.
6.Insert the mounting screws (provided with the thermostat) into the wall anchors. Check leveling, if desired, and tighten the mounting screws.
WALL OPENING
WALL ANCHORS (2) (PROVIDED WITH THERMOSTAT)
WIRE
WALL
DRILLED HOLES (2)
COVER PLATE
WIRE HOLE
MOUNTING HOLES (2)
WALL PLATE
WIRE HOLE
MOUNTING HOLES (2)
MOUNTING SCREWS (2) (PROVIDED WITH THERMOSTAT)
THERMOSTAT
M34259
Fig. 2. Mount cover plate, wall plate and thermostat directly to wall.
69-2762EFS—01 |
2 |
THP2400A1019 COVER PLATE ASSEMBLY
Mount Cover Plate to a Vertical 2 in. X 4 in. Electrical Box (See Fig. 3)
1.Position the bracket on the electrical box. Insert two #6-32 X 5/8 flat head screws. Check leveling, if desired, and tighten the flat head screws.
2.Pull the wires through the wire hole on the cover plate and wall plate. Position the cover plate and wall plate on the bracket with the arrows pointing up.
3.Insert two #6-32 X 1/4 pan head screws and tighten.
ELECTRICAL BOX
WIRE
BRACKET
#6-32 X 5/8 FLAT HEAD SCREWS (2)
COVER PLATE
WIRE HOLE
MOUNTING HOLES (2)
WALL PLATE
WIRE HOLE
MOUNTING HOLES (2)
#6-32 X 1/4 PAN HEAD SCREWS (2)
THERMOSTAT
M34260
Fig. 3. Mount bracket, cover plate, wall plate and thermostat to a vertical 2 in. X 4 in. electrical box.
3 |
69-2762EFS—01 |
THP2400A1019 COVER PLATE ASSEMBLY
Mount Cover Plate to a Horizontal 2 in. X 4 in. Electrical Box (See Fig 4)
1.Pull the wires through the wire hole on the cover plate and wall plate. Position the cover plate and wall plate on the electrical box with the arrows pointing up.
2.Insert two #6-32 X 5/8 flat head screws. Check leveling, if desired, and tighten the flat head screws.
ELECTRICAL BOX
WIRE
COVER PLATE
WIRE HOLE
MOUNTING HOLES (2)
WALL PLATE
WIRE HOLE
MOUNTING HOLES (2)
#6-32 X 5/8 FLAT HEAD SCREWS (2)
THERMOSTAT
M34261
Fig. 4. Mount cover plate, wall plate and thermostat to a horizontal 2 in. X 4 in. electrical box.
Automation and Control Solutions
Honeywell International Inc.
1985 Douglas Drive North
Golden Valley, MN 55422 customer.honeywell.com
® U.S. Registered Trademark
© 2012 Honeywell International Inc.
69-2762EFS—01 M.S. 10-12