T8600, T8601, T8602, T8611, T8624
Thermostats
INSTALLATION INSTRUCTIONS AND OWNER GUIDES ADDENDUM
FURNACE AIR FILTER, HUMIDIFIER PAD AND ULTRAVIOLET (UV) LAMP
TIMERS
The thermostat has up to three timers to help the homeowner remember when to change or clean the furnace air filter,
whole-house humidifier pad or ultraviolet air treatment system UV lamp. See Table 1.
Table 1. Thermostat timers.
Type of Thermostat
Timer Measurement
Calendar days in any mode. Furnace air filter and UV lamp timers UV lamp timer
Calendar days in Heat mode only. Humidifier pad timer Humidifier pad timer
System run time in any mode. — Furnace air filter timer
Manual System Switches
(Heat, Off, Cool)
View or Reset Timer Settings
When the thermostat activates a timer, the thermostat
flashes Filter until the timer resets.
1. Reset the timer by pressing the i key until the
expired timer is displayed.
Filter
2. Press the Time ▲key to reset the timer.
Days
M2024
3. Press the Run Program key.
NOTE: You can view the number of days remaining at
any time by pressing the i key three or four
times. If more than one timer is active, all active
timers show sequentially when pressing the
i key several times.
For complete instructions on replacing or cleaning your
furnace filter, humidifer pad or UV lamp, see the product
owner’s manuals. Contact your local contractor or visit
www.honeywell.com/yourhome.
For instructions on entering Installer Setup mode, see
product installation instructions (installers only). Table 2
gives Installer Setup instructions for the timers.
Pushbutton System Keys
(Heat, Off, Cool)
Filter
® U.S. Registered Trademark
Copyright © 2002 Honeywell • •All Rights Reserved
Days
M2024
69-1584-1
T8600, T8601, T8602, T8611, T8624 THERMOSTATS
Table 2. Timer Installer Setup.
Factory Setting Other Choices
Display Description Display Description
Selection
Furnace air filter
timer
(pushbutton
System keys)
Furnace air filter
timer (manual
System
switches)
Humidifier pad
monitor
Ultraviolet air
treatment (UV)
system lamp
monitor
Installer Setup
Number
43 2 30 days
43 2 90 days
44 0 Off 1, 2, 3 1- 90 days
45 0 Off 1 1 - 365 days
(System run
time)
(calendar days)
0, 1, 3, 4 0 - off
0, 1, 3, 4 0 - off
1- 10 days
3 - 60 days
4 - 120 days
(Time is counted
when heat, cool or
fan is running)
1- 30 days
3 - 180 days
4 - 365 days
(Time is counted
by calendar days
in any mode.)
2 - 180 days
3 - 365 days
(Time is counted
by calendar days
in heat mode.)
(Time is counted
by calendar days
in any mode.)
Automation and Control Solutions
Honeywell Honeywell Limited-Honeywell Limitée
1985 Douglas Drive North 35 Dynamic Drive
Golden Valley, MN 55422 Scarborough, Ontario
69-1584-1 G.H. Rev. 9-02 www.honeywell.com/yourhome
M1V 4Z9
Printed in U.S.A. on recycled
paper containing at least 10%