Pentair Everpure i2000 Manual

0 (0)
Pentair Everpure i2000 Manual

EVERPURE® i20002 FILTER CARTRIDGE

DELIVERS PREMIUM QUALITY WATER FOR ICE APPLICATIONS

i20002 Replacement Cartridge: EV9612-22

APPLICATIONS

Ice

FEATURES • BENEFITS

Proprietary Micro-Pure® II filtration media effectively inhibits the growth of bacteria on the filter media that can decrease product life

Sanitary cartridge replacement is simple, quick and clean. Internal filter parts are never exposed to handling

or contamination

Reduces water-related ice machine problems caused by scale buildup from dirt and dissolved minerals*

Self-contained scale inhibitor feed keeps ice machines functioning at full capacity*

Reduces maintenance and service costs by reducing scale and clogging of distribution lines, evaporator plate and pump*

Exclusive precoat filtration provides superior chlorine taste and odor reduction and micro-filters dirt and particles as small as 0.5 micron in size by

mechanical means.

NSF/ANSI Standard 53 certified to reduce cysts such as Cryptosporidium and Giardia by mechanical means

INSTALLATION TIPS

OPERATION TIPS

SIZING

Install vertically with cartridge hanging down

Allow 2-1/2" (6.35 cm) clearance below the cartridge for easy cartridge replacement

Flush cartridge by running water through filter for five (5) minutes at full flow

Change cartridges on a regular six (6) month preventative maintenance program

Change cartridges when capacity is reached or when pressure falls below 10 psi (0.7 bar)

Always flush the filter cartridge at time of installation and cartridge change

Service Flow Rate: Maximum 1.67 gpm (6.3 Lpm)

Capacity: 9,000 gallons (34,069 L)

*As tested by Everpure

FILTRATION & PROCESSING SOLUTIONS EV9612-22 SPECIFICATION SHEET