Installation and Operation Guide
QC7I Series Water Filters
SELECTING A MOUNTING LOCATION
1.Give consideration to the weight of the unit when operating (filled with water). Operating weights of the QC7I Systems are:
•Single System - 9 lbs. (4.0 kg.)
•Twin System - 19 lbs. (8.5 kg)
•Triple System - 27 lbs. (12 kg)
•Quad System - 36 lbs. (20 kg)
2.The location should allow for:
•Minimum clearance of 2-1/2” under the cartridge(s) so it can be lowered for removal and replacement.
•Adequate space for “in” and “out” water line connections.
•Be near a drain for flushing and near a 110V outlet if the accessory (sold separately) Everguard Low Pressure Alarm is used. See Figures 1-8.
3.If used in conjunction with the SR-X feeder, the SR-X should be mounted after the QC7I Series Filter and as near the equipment as possible. If possible, keep at least 6” available to the left and the right of the QC7I System in the event poor quality water conditions require the installation of the optional Everpure E-Series Prefilter.
WARNING: Do not use the MH cartridge in conjunction with the SR-X.
OPERATING SPECIFICATIONS*
|
Replacement |
|
|
Combined Model Name |
Cartridge |
Flow Rate |
Capacity |
|
|
|
|
QC7I Single - MC |
MC |
1.67 gpm (6.3 lpm) |
9,000 gal (34,000 L) |
QC7I Single - MC2 |
MC2 |
1.67 gpm (6.3 lpm) |
9,000 gal (34,000 L) |
QC7I Single - MH |
MH |
1.67 gpm (6.3 lpm) |
9,000 gal (34,000 L) |
QC7I Single - MH2 |
MH2 |
1.67 gpm (6.3 lpm) |
9,000 gal (34,000 L) |
QC7I Single - TO |
TO |
1.5 gpm (18.9 lpm) |
30,000 gal (113,550 L) |
QC7I Single - CV |
CV |
1.67 gpm (6.3 lpm) |
7,500 gal (28,390 L) |
QC7I Single - XCV |
XCV |
1.67 gpm (6.3 lpm) |
10,000 gal (37,850 L) |
QC7I Single - XC |
XC |
1.67 gpm (6.3 lpm) |
12,000 gal (45,420 L) |
QC7I Single - XC2 |
XC2 |
1.67 gpm (6.3 lpm) |
12,000 gal (45,420 L) |
QC7I Single - 7CB5 |
7CB5 |
2.5 gpm (9.4 lpm) |
10,000 gal (37,850 L) |
QC7I Single - 7CB5-K |
7CB5-K |
2.5 gpm (9.4 lpm) |
10,000 gal (37,850 L) |
QC7I Single - 7CB5-S |
7CB5-S |
2.5 gpm (9.4 lpm) |
10,000 gal (37,850 L) |
|
Replacement |
|
|
|
|
|
|
Combined Model Name |
Cartridge |
Flow Rate |
Capacity |
|
|
|
|
QC7I Twin - MC |
MC |
3.3 gpm (12.6 lpm) |
18,000 gal (68,000 L) |
QC7I Twin - MC2 |
MC2 |
3.3 gpm (12.6 lpm) |
18,000 gal (68,000 L) |
QC7I Twin - MH |
MH |
3.3 gpm (12.6 lpm) |
18,000 gal (68,000 L) |
QC7I Twin - MH2 |
MH2 |
3.3 gpm (12.6 lpm) |
18,000 gal (68,000 L) |
QC7I Twin - TO |
TO |
3.0 gpm (37.8 lpm) |
60,000 gal (227,100 L) |
QC7I Twin - CV |
CV |
3.3 gpm (12.6 lpm) |
15,000 gal (56,780 L) |
QC7I Twin - XCV |
XCV |
3.3 gpm (12.6 lpm) |
20,000 gal (75,700 L) |
QC7I Twin - XC |
XC |
3.3 gpm (12.6 lpm) |
24,000 gal (90,840 L) |
QC7I Twin - XC2 |
XC2 |
3.3 gpm (12.6 lpm) |
24,000 gal (90,840 L) |
QC7I Twin - 7CB5 |
7CB5 |
5.0 gpm (18.9 lpm) |
20,000 gal (75,700 L) |
QC7I Twin - 7CB5-K |
7CB5-K |
5.0 gpm (18.9 lpm) |
20,000 gal (75,700 L) |
QC7I Twin - 7CB5-S |
7CB5-S |
5.0 gpm (18.9 lpm) |
20,000 gal (75,700 L) |
Figure 1 – Single System
Figure 2 – Twin System
Figure 3 – Triple System
Figure 4 – Quad System
Manufactured by Everpure |
EV3024-87D DE05 |
|
Replacement |
|
|
Combined Model Name |
Cartridge |
Flow Rate |
Capacity |
|
|
|
|
QC7I Triple - MC |
MC |
5.0 gpm (18.9 lpm) |
27,000 gal (102,000 L) |
QC7I Triple - MC2 |
MC2 |
5.0 gpm (18.9 lpm) |
27,000 gal (102,000 L) |
QC7I Triple - MH |
MH |
5.0 gpm (18.9 lpm) |
27,000 gal (102,000 L) |
QC7I Triple - MH2 |
MH2 |
5.0 gpm (18.9 lpm) |
27,000 gal (102,000 L) |
QC7I Triple - TO |
TO |
4.5 gpm (56.7 lpm) |
90,000 gal (340,650 L) |
QC7I Triple - CV |
CV |
5.0 gpm (18.9 lpm) |
22,500 gal (85,170 L) |
QC7I Triple - XCV |
XCV |
5.0 gpm (18.9 lpm) |
30,000 gal (113,550 L) |
QC7I Triple - XC |
XC |
5.0 gpm (18.9 lpm) |
36,000 gal (136,260 L) |
QC7I Triple - XC2 |
XC2 |
5.0 gpm (18.9 lpm) |
36,000 gal (136,260 L) |
QC7I Triple - 7CB5 |
7CB5 |
7.5 gpm (28.2 lpm) |
30,000 gal (113,550 L) |
QC7I Triple - 7CB5-K |
7CB5-K |
7.5 gpm (28.2 lpm) |
30,000 gal (113,550 L) |
QC7I Triple - 7CB5-S |
7CB5-S |
7.5 gpm (28.2 lpm) |
30,000 gal (113,550 L) |
|
Replacement |
|
|
|
|
|
|
Combined Model Name |
Cartridge |
Flow Rate |
Capacity |
|
|
|
|
QC7I Quad - MC |
MC |
6.6 gpm (25 lpm) |
36,000 gal (136,000 L) |
QC7I Quad - MC2 |
MC2 |
6.6 gpm (25 lpm) |
36,000 gal (136,000 L) |
QC7I Quad - MH |
MH |
6.6 gpm (25 lpm) |
36,000 gal (136,000 L) |
QC7I Quad - MH2 |
MH2 |
6.6 gpm (25 lpm) |
36,000 gal (136,000 L) |
QC7I Quad - TO |
TO |
6.0 gpm (22.4 lpm) |
120,000 gal (454,200 L) |
QC7I Quad - CV |
CV |
6.6 gpm (25 lpm) |
30,000 gal (113,550 L) |
QC7I Quad - XCV |
XCV |
6.6 gpm (25 lpm) |
40,000 gal (151,400 L) |
QC7I Quad - XC |
XC |
6.6 gpm (25 lpm) |
48,000 gal (181,680 L) |
QC7I Quad - XC2 |
XC2 |
6.6 gpm (25 lpm) |
48,000 gal (181,680 L) |
QC7I Quad - 7CB5 |
7CB5 |
10.0 gpm (37.6 lpm) |
40,000 gal (151,400 L) |
QC7I Quad - 7CB5-K |
7CB5-K |
10.0 gpm (37.6 lpm) |
40,000 gal (151,400 L) |
QC7I Quad - 7CB5-S |
7CB5-S |
10.0 gpm (37.6 lpm) |
40,000 gal (151,400 L) |
* For individual cartridge specifications, refer to cartridge literature.
Temperature: 35-100°F (2-38°C)
Pressure: 10 - 125 psi (0.7 - 8.6 bar), non-shock For cold water use only.
INSTALLATION
1.Use the predrilled mounting holes in the manifold bracket as guides. Mark and drill anchor holes. Mount securely. See Figures 5-8.
2.Shut off power to machine.
3.Connect outlet port of QC7I unit to equipment served. Always use a NSF approved pipe dope or Teflon tape at all connections. Use a backup wrench on all fittings while connecting to avoid excessive stress on the system components.
Note: If the optional E-Series Filter is used, install a manual shut-off valve leading to the system for servicing.
4.Connect minimum 3/8” water line to inlet side of QC7I singles. Use minimum 1/2” line for other systems.
5.The cross fitting has a flushing valve installed on the bottom. Connect tubing to flushing valve and run to drain.
Note: Some municipal plumbing codes and good sanitary practices require an air gap at the drain termination point.
6.Install the cartridge(s) into the QC7I head (s) following directions on the cartridge label or as shown in the Cartridge Change illustrations.
7.Turn on water to filter and check for leaks.
8.Flush the cartridge by running water through at full force for five minutes. This will set the filtering media and purge air and fines, insuring maximum filter life.
9.After flushing, close the flushing valve, turn on power to equipment and plug the LPA (if so equipped) into the electrical outlet. See illustrations.
5.60"
INLET |
OUTLET |
3/8" FNPT |
3/8" FNPT |
27.50"
Figure 5 – Single System
16.60"
OUTLET
3/4" FNPT
INLET 3/4" MNPT
25.26"
Figure 6 – Twin System
21"
OUTLET
3/4" FNPT
INLET 3/4" MNPT
29.26"
Figure 7 – Triple System
24.60"
OUTLET
3/4" FNPT
INLET 3/4" MNPT
29.69"
Figure 8 – Quad System
Check for compliance with state and local laws and regulations. Do not use with water that is
microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.