EVERPURE® MRS-600HE HIGH EFFICIENCY RO SYSTEM
HIGH OUTPUT/HIGH EFFICIENCY CONFIGURABLE SYSTEM THAT DELIVERS RO AND BLENDED FILTERED WATER FOR MULTIPLE FOODSERVICE APPLICATIONS
MRS-600HE System:
EV9970-38; EV9970-44; EV9970-47; EV9970-50
MR-600 Cartridge EV9627-13
2SR-BW Cartridge EV9627-14
GS-215RO-H In-line Filter EV9627-15
APPLICATIONS
Mineral Reduction System For Foodservice Ideal For Specialty Coffee Applications Including Coffee Brewers,
Espresso, Steamers, Combi Ovens, and Ice
FEATURES • BENEFITS
The tailored blending process removes just the right amount of dissolved solids from the incoming tap water to achieve the desired final water quality
With the average recovery of 78%, the MRS-600HE system only disposes approximately 1/4 cup of water for each cup of water dispensed
High recovery reverse osmosis technology yields significant savings in water and sewer charges with a minimal environmental footprint
Requires less than 50% of the electrical energy typically consumed by conventional reverse osmosis systems
On board storage tank provides ample reserve capacity for most applications - For increased reserve capacity, Pentair offers a complete line of storage tanks
Reduces limescale buildup that can cause excessive machine downtime and increased maintenance costs
Reduces chlorine taste and odor and other contaminants that can adversely affect the taste of water and beverages
INSTALLATION TIPS |
OPERATION TIPS |
SIZING |
Choose a mounting location capable of safely supporting the full weight of the system when in operation.
Deliming of existing water using equipment is recommended.
Never use saddle valve for connection. Use 3/8" (9.5 mm) minimum water line.
Install vertically with cartridges hanging down and allow 3" (76 mm) on all four (4) sides of unit for cover removal and service access.
The product water tubing/piping and associated fittings connecting the RO product outlet to the equipment being serviced should be suitable for use with high purity water.
Change filter cartridges on a regular six (6) month preventative maintenance program.
Change RO cartridges on a regular one year preventative maintenance program.
Change cartridges when capacity is reached.
Always flush the filter cartridge at time of installation and cartridge change.
Refer to Installation, Operation & Maintainance Manual for cartridge flushing and RO startup.
The water inlet must supply a minimum of 1.5 gpm (5.7 Lpm)
Service Flow Rate: Dependant on water pressure in storage tank and line size(s) to equipment
FILTRATION & PROCESSING SOLUTIONS MRS-600HE SPECIFICATION SHEET