Pentair Everpure PBS-400 Installation Manual

0 (0)

Everpure® PBS-400 Water Filtration System

Sistema de filtración de agua PBS-400 PBS-400 Système de filtrage d’eau

©2013 Pentair Residential Filtration, LLC

www.pentairaqua.com

ENGLISH

Thank you for purchasing an Everpure by Pentair commercialgrade water filtration system for your home. With your Everpure by Pentair system, you get premium quality water direct from your tap that’s great-tasting, healthful and convenient for you and your family.

Product Specifications

For Cold Water Use Only

Temperature Range: 35-100°F (2-38°C)

Min.-Max. Working Pressure: 10-125 psi (0.7-8.6 bar)

Service Flow Rate: 2.2 gpm (8.3 Lpm)

Capacity: 3,000 gallons (11,355 L)

TOOLS REQUIRED FOR INSTALLATION

Phillips Screwdriver

Adjustable Wrench

Tape Measure

Pencil

Basic Installation Instructions

1. Open Carton & Inspect Parts

Installation Parts

Key

Description

Part No.

1

QL3 Filter Head

EV927082

2

PBS-400 Filter Cartridge

EV927086

3

2 Locking Washers

EV306204

4

2 Screws

EV306196

5

3/8-inch MPT x 3/8-inch FTP Elbow

EV310852

6

(2) 3/8-inch x 1/2-inch Unions

EV312251

7

(2) 3/8-inch x 3/8-inch Unions

EV312250

8

Tubing, 3/8-inch Braided

EV312249

9

Plumber Tape

EV312119

10

Everpure Filter Timer

EV314160

 

 

 

2. Verify Under-Sink Mounting Location

Measure 20 inches from the base of the cabinet, and mark the mounting location for the top of the filter head. Make sure there is adequate space above the head to open and close the built in shut-off valve and to avoid crimping the water line tubing. Also, make sure your chosen location offers easy access for future cartridge changes.

DIMENSION

Width

Mounting

Depth

Height

 

 

 

PBS-400

5 inches

20 inches

5 inches

NOTE: The head and cartridge must be mounted in the vertical position, with the cartridge hanging down.

1

3

 

 

1

4

5

 

 

 

 

6

7

2

8

10

9

2

20 inches

2 • EVERPURE® PBS-400 Water Filtration System

Pentair Everpure PBS-400 Installation  Manual

Basic Installation Instructions

3

A

 

 

continued

 

D

 

 

 

3. Mount Filter Head Under Sink

 

B

C

 

 

NOTE: Two sets of unions are included to connect to the 3/8-

 

 

 

inch head connections. If your existing braided tubing

 

 

 

ENGLISH

has 1/2-inch connections, use the 1/2-inch x 3/8-inch

 

 

 

unions instead of the 3/8-inch x 3/8 inch unions. You

 

 

 

will have 2 extra fittings with either installation.

 

 

 

The following instructions are for a typical

 

 

 

installation using 1/2-inch supply lines.

 

 

 

 

A. Apply plumber tape to the small threads of one Union

 

 

 

 

Fitting and screw into the open end of the Elbow. Wrap tape

4

 

 

 

in direction of the threads to assure a tight fit and avoid

 

 

F

small leaks.

 

 

 

 

 

 

 

B. Apply plumber tape to the threads of the Elbow Fitting

 

E

 

H

and screw into the inlet (left) side of the Filter Head. Hand

 

 

tighten only.

 

 

 

 

C. Apply plumber tape to the small threads of the second

 

 

 

G

Union Fitting, and screw into the right side of the filter

 

 

 

head in the same manner.

 

 

 

 

D. Securely mount the filter head on the cabinet wall using

 

 

 

 

the enclosed mounting screws and washers.

 

 

 

 

4. Connect Inlet Water Supply

E.Locate and close the cold water shut-off valve under your sink. Open cold water line of faucet to release

water pressure.

F.Unscrew and disconnect the braided tubing on top of cold water shut-off valve.

G.Attach one end of the new braided tubing to the top of the cold water shut-off valve.

H.Attach the other end of the new Braided Tubing to the inlet side of the filter head (Union & Elbow Fittings).

5. Attach Filtered Water To Cold Line of Faucet

I.Attach open end of existing Braided Tubing to Union Fitting on outlet side (right) of new Filter Head. Hand tighten to avoid damage to fittings.

6. Install And Flush Filter Cartridge

J.Lift handle of the build-in shut off (QC Valve) on the Head.

K.Hold Head firmly with one hand.

L.Align cartridge lug with label on filter Head.

M.Insert filter Cartridge—Push upwards.

N.Turn it to the right—About 1⁄4 turn—Until rotation stops.

O.Open cold water valve and check for leaks up to Inlet Elbow Fitting.

P.Open Water Faucet (not pictured).

Q.Lower the QC Valve Handle to flush water to the sink.

NOTE: Flush new filter cartridges for at least 3 minutes to remove air and any loose carbon. At first the water may appear cloudy due to trapped air in the filter and tubing. If water continues to be cloudy for more that one week, please contact Pentair Technical Support for assistance: (800) 279-9404

R.Activate Filter Timer by pinching bubble until you feel a change in resistance as the Filter timer “pops.” Within a few seconds, a thin RED line will appear in the white window showing the Timestrip® has been activated. Peel away backing and adhere to desired location. When the white window is completely filled with RED, it is time to replace your product.

5

I

6 J

N

K

L

Label

M Lug

Q O

EVERPURE® PBS-400 Water Filtration System • 3

ENGLISH

HEALTH CLAIM PERFORMANCE CLASSIFIED BY UL

This system has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53.

 

 

Max.

 

 

 

 

Influent

Permissible

 

 

 

 

Challenge

Product Water

Reduction

Minimum

Average

Substance

Concentration

Concentration

Requirements

Reduction

Reduction

 

 

 

 

 

Standard 42—Aesthetic Effects

 

 

 

 

 

 

 

 

 

 

Chlorine

2.0 mg/L ± 10%

 

≥ 50%

 

98%

Particulate,

 

 

 

 

 

Class I

at least 10,000

 

 

 

 

particles

 

≥ 85%

 

99.8%

particles/mL

 

 

0.5 to <1

 

 

 

 

 

 

 

 

 

µm

 

 

 

 

 

Standard 53—Health Effects

 

 

 

 

 

 

 

 

 

 

Cyst

Minimum

 

99.95%

99.99%

99.99%

50,000/L

 

 

 

 

 

 

Lead 8.5

0.15 mg/L ± 10%

0.010 mg/L

 

94.1%

97.2%

Lead 6.5

0.15 mg/L ± 10%

0.010 mg/L

 

98.9%

98.9%

NOTE: This installation must comply with all applicable state and local regulations.

NOTE: Maximum working pressure 125 psi.

NOTE: Do no use with water that is microbiologically unsafe or unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on waters that may contain filterable cysts.

NOTE: Testing was performed under standard laboratory conditions, actual performance may vary.

NOTE: This drinking water system must be maintained according to manufacturer’s instructions, including replacement of filter cartridges. Suggested retail $134.99.

California Proposition 65 Warning

WARNING: This product contains chemicals known to the State of California to cause cancer or birth defects or other reproductive harm.

Reduces particles as small as 0.5 micron in size by mechanical means.

NSF/ANSI Standard 53 certified to reduce cysts such as Cryptosporidium and Giardia by mechanical means.

This Filter System has been Tested & Certified by

the WQA against NSF/ANSI Std. 42,53, 372 & CSA B483.1

This System has been Tested & Certified by WQA against Std. 42 & 53 as verified and substantiated by test data for the reduction of:

Std. No. 42—Aesthetic

Std. No. 53—Health

effects

effects

Chemical Reduction

Chemical Reduction

Chlorine

Lead

Taste & Odor

Mechanical Filtration

Mechanical Filtration

Cyst

Nominal Particulate

 

Class I

 

EPA Est. No. 002623-IL-002

State of California Department of Public Health

Water Treatment Device

Certificate Number

13-2213

 

Date Issued: December 5, 2013

Trademark/Model Designation

Replacement Elements

EverPure PBS-400

PBS-400

Manufacturer: Pentair Residential Filtration, LLC.

The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section 116830 of the Health and Safety Code for the following health related contaminants:

Microbiological Contaminants and Turbidity

Inorganic/Radiological Contaminants

Cysts

Lead

Organic Contaminants

None

Rated Service Capacity 3,000 gallons

Rated Service Flow: 2.2 gallons per minute

Conditions of Certification

Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems for cyst reduction may be used on disinfected waters that contain filterable cysts.

4 • EVERPURE® PBS-400 Water Filtration System

ENGLISH

EVERPURE® PBS-400 Water Filtration System • 5

Loading...