Peerless-AV PFT660 User Manual

Installation and Assembly - Vector Pro II
Models: PJF2 Series Refer to Model No. Guide Sheet
This product is intended for use with UL
R
Listed products and must be installed by a qualified professional installer.
Maximum UL Load Capacity: 50 lb (27 kg)
Read instruction sheet before you start installation and assembly.
WARNING
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
IMPORTANT! Be sure not to touch the projector while tightening the set screw on the ball and socket mount. This may cause the image to be unaligned when you let go.
IMPORTANT! Turn to the appropriate page for your ceiling installation.
Flush Mount .................................................................................................................................................. page 6
Extension Column ........................................................................................................................................ page 7
Installations:
To Wood Joist Finished Ceilings,
Exposed Wood Joists, or Wood Beam Ceilings ........................................................................................ page 4
To Concrete Ceilings .................................................................................................................................... page 5
Visit the Peerless Web Site at www.peerlessmounts.com
1 of 7
ISSUED: 05-25-05 SHEET #: 055-9247-7 11-08-06
For customer care call 1-800-729-0307 or 708-865-8870.
Before you start check the parts list to insure all of the parts shown are included.
Parts List
Black Silver
Description Qty. Part Number Part Number
A ball and socket mount 1 055-001 1 055-0016 B 4 mm security allen wrench 1 560-9646 560-9646 C M5 x .8 x 10 mm socket pin type F screw 1 520-1164 520-2031 D #10-32 x 3/8" spade thumb screw 1 560-1107 560-2107 E #10-32 x 3/8" serrated washer head socket pin screw 1 520-1151 520-2151 F #14 x 2.5 phillips hex head wood screw 2 5S1-015-C03 5S1-015-C04 G ceiling plate 1 580-1042 580-4042 H .25" ID x .56" OD x .26 spacer 2 590-1050 590-2071 I extension column connector with cord management 1 580-1025 580-4025 J #10-32 x 3/8" socket pin screw 2 520-1084 520-2084 K #10-32 x 3/16" slotted set screw 3 520-1187 520-2187
A
G
Note: Actual parts may appear slightly different than illustrated.
C
D
J
E
H
I
K
F
B
FASTENERS
Visit the Peerless Web Site at www.peerlessmounts.com
2 of 7
ISSUED: 05-25-05 SHEET #: 055-9247-7 11-08-06
For customer care call 1-800-729-0307 or 708-865-8870.
Installation To Wood Joist Finished Ceilings, Exposed Wood Joists, or Wood Beam Ceilings
Drill two 5/32" (4 mm) dia. holes to a minimum depth of 2.5" (64 mm). Attach ceiling plate (G) with two #14 x 2.5" (6 mm x 65 mm) wood screws (F) as shown using 3/8" (10 mm) socket wrench.
Skip to step 2.
WOOD JOIST
WARNING
• Tighten wood screws (F) so that wall plate (G) is firmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.
• Never tighten in excess of 80 in • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the studs. The use of an "edge to edge" stud finder is highly recommended.
WARNING
• It is the responsibility of the installer to verify that the supporting surface will safely support the combined load of all attached hardware and components.
IMPORTANT: Be sure to drill holes into the joist CENTER!
CEILING
G
F
F
WOOD JOIST
CEILING
H
F
Visit the Peerless Web Site at www.peerlessmounts.com
F
H
G
3 of 7
For optional Cord Management,
install two spacers (H) between ceiling plate (G) and ceiling.
ISSUED: 05-25-05 SHEET #: 055-9247-7 11-08-06
For customer care call 1-800-729-0307 or 708-865-8870.
WARNING
• When installing Peerless wall mounts on concrete, verify that you have a minimum of 1 5/8" of actual concrete surface in the 1/4" diameter hole to be used for the concrete anchors. Do not drill into mortar joints! Concrete must meet ASTM C-90 specifications.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard­ware and components.
• Never exceed the Maximum UL Load Capacity of 50 lb (27 kg).
Installation to Concrete Ceilings
ACC 203 (Alligator® concrete anchors) are recommended.
Drill two 1/4" (6 mm) dia. holes to a minimum depth of
2.5" (64 mm). Attach ceiling plate (G) using two concrete anchors and #14 x 2.5" wood screws (F) as shown in Illustration A and 1, 2, and 3 (below). Tighten all fasteners.
IMPORTANT: It is the responsibility of the installer to verify that the ceiling will safely support the combined load of all attached hardware and components.
concrete anchor
CONCRETE CEILING
WARNING
• Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.
• Never tighten in excess of 80 in • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the studs. The use of an "edge to edge" stud finder is highly recommended.
1
Drill hole and insert anchor
2
G
F
Place ceiling plate over anchor and secure with screw
3
concrete ceiling
concrete anchor
concrete anchor
G
F
Illustration A
WARNING
FOR DIRECT ATTACHMENT TO LOAD BEARING CONCRETE ONLY! Concrete expansion anchors are not intended for attachment to concrete ceilings
covered with a layer of plaster, drywall, or other finishing material. If mounting to concrete ceiling covered with plaster / drywall is unavoidable, plaster / drywall must be counterbored as shown below.
metal bracket
INCORRECT
concrete
metal bracket
CORRECT
concrete
concrete anchor
F
After repeating step one tighten all fasteners
Visit the Peerless Web Site at www.peerlessmounts.com
4 of 7
CUTAWAY VIEW
plaster/ dry wall
ISSUED: 05-25-05 SHEET #: 055-9247-7 11-08-06
For customer care call 1-800-729-0307 or 708-865-8870.
plaster/ dry wall
Flush Mount Application
Screw ball and socket mount (A) into ceiling plate (G). Align the notch with one of the four holes of the ceiling plate (G) and secure ball and socket mount (A) with a M5 x 10 mm socket pin screw (C) using security allen wrench (B) as shown in detail 1. Note: Slotted set screw (K) is used to jam against the threads of the ball and socket mount to prevent any excess movement of the ball and socket mount (A). Do not overtighten screw; overtightening screw will damage threads making it difficult to separate the products.
Skip to step 3.
K
NOTCH
CEILING
WOOD
G
A
C
A
G
DETAIL 1
Visit the Peerless Web Site at www.peerlessmounts.com
5 of 7
ISSUED: 05-25-05 SHEET #: 055-9247-7 11-08-06
For customer care call 1-800-729-0307 or 708-865-8870.
Installation to Extension Column
G
C
K
Screw extension column to ceiling plate (G). Align the notch with one of the four holes in the ceiling plate (G) and secure extension column with a M5 x 10 mm socket pin screw (C) using security allen wrench (B).
See detail 4.
Screw extension column connector (I) to extension column. Align slot in extension column with one of the top holes in extension column connector (I). Insert and tighten one #10-32 x 3/8" socket pin screw (J) through extension column connector (I) into slot on extension column using security allen wrench (B). See detail 5.
Screw ball and socket mount (A) to extension column connector (I). Align slot in ball and socket mount (A) to one of the bottom holes in extension column connector (I). Insert and tighten one #10-32 x 3/8" socket pin screw (J) through extension column connector into slot in ball and socket mount (A) using security allen wrench (B). See detail 6.
EXTENSION COLUMN (UL Listed EXT or ADJ Series) Sold Separately
SLOT
I
SLOT
EXTENSION COLUMN
K
I
G
EXTENSION COLUMN
DETAIL 4
SLOT
J
Note: Slotted set screws (K) are used to
jam against the threads of each connecting joint to prevent any excess movement. Do not overtighten screws; overtightening screws will damage threads making it difficult to separate the products.
A
I
A
DETAIL 5
EXTENSION COLUMN
SLOT
K
J
DETAIL 6
Visit the Peerless Web Site at www.peerlessmounts.com
6 of 7
ISSUED: 05-25-05 SHEET #: 055-9247-7 11-08-06
For customer care call 1-800-729-0307 or 708-865-8870.
Note: The projector adapter plate and projector you are installing may differ in appearance from the sample illustrated below.
Attach projector, with adapter plate already on it, to the ball and socket mount (A) by inserting the ball and socket mount (A) into the adapter plate connection and twisting until the adapter plate will no longer turn (about 75°). The spring loaded captive screw should line up with a corresponding hole on the adapter plate (this should line up automatically when the two are connected). Push down and tighten the spring loaded captive screw to secure the adapter plate to the mount. If not using the optional security feature, fasten thumb screw (D) in the hole opposite the spring loaded captive screw.
OPTIONAL: For Armor Lock
washer head socket pin security screw (E) in the hole opposite the spring loaded captive screw. Tighten with security allen wrench (B). This will prevent the projector from being removed.
Note: Be sure to only use the #10-32 x 3/8" screw (E) (or the thumb screw (D)) opposite the spring loaded captive screw.
CEILING
CAPTIVE
SCREW
security, insert serrated
E
WOOD JOIST
A
To adjust roll, pitch, and yaw loosen the set screw (shown below) using security allen wrench (B) or standard 4 mm allen wrench. You should be able to just slightly loosen the screw so that your adjustments can be set without having to hold the projector. Move projector to desired position and slowly tighten set screw.
Note: Be sure not to touch the projector while tightening the set screw. This may cause the image to be unaligned when you let go.
IMPORTANT: Allen wrench is your key for projector removal. Store it in a safe place.
WOOD JOIST
CEILING
SET SCREW
D
PROJECTOR
CUTAWAY VIEW OF CEILING PLATE (G)
1
2
PROJECTOR ADAPTER PLATE (UL Listed PAP Series) Sold Separately
PROJECTOR
Peerless offers several Projector Mounts to fit various projectors. New Projector Mounts are continually being developed to meet the demands of a growing projector market. To find out if a mount is available for your particular projector, call Peerless customer service at 1-800-729­0307 or 1-708-865-8870.
WARNING
• Do not lift more weight than you can handle! Use additional man power or mechanical lifting equipment to safely handle placement of the projector!
7 of 7
Visit the Peerless Web Site at www.peerlessmounts.com
© 2005 Peerless Industries, Inc. All rights reserved. Peerless is a registered trademark of Peerless Industries, Inc. Vertor Pro II and Armor Lock are trademarks of Peerless Industries Inc. All other brand and product names are trademarks or registered trademarks of their respective owners.
ISSUED: 05-25-05 SHEET #: 055-9247-7 11-08-06
For customer care call 1-800-729-0307 or 708-865-8870.
Loading...