Installation and Assembly - Vector Pro II™ |
Models: PJF2 Series |
|
Refer to Model No. Guide Sheet |
|
|
R
This product is intended for use with UL Listed products and must be installed by a qualified professional installer.
Maximum UL Load Capacity: 50 lb (27 kg)
Read instruction sheet before you start installation and assembly.
WARNING
•Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
IMPORTANT! Be sure not to touch the projector while tightening the set screw on the ball and socket mount. This may cause the image to be unaligned when you let go.
IMPORTANT! Turn to the appropriate page for your ceiling installation.
Applications: |
|
Flush Mount .................................................................................................................................................. |
page 6 |
Extension Column ........................................................................................................................................ |
page 7 |
Installations: |
|
To Wood Joist Finished Ceilings, |
|
Exposed Wood Joists, or Wood Beam Ceilings ........................................................................................ |
page 4 |
To Concrete Ceilings .................................................................................................................................... |
page 5 |
|
|
1 of 7 |
ISSUED: 05-25-05 SHEET #: 055-9247-7 11-08-06 |
Visit the Peerless Web Site at www.peerlessmounts.com |
For customer care call 1-800-729-0307 or 708-865-8870. |
Before you start check the parts list to insure all of the parts shown are included.
Parts List
|
|
|
|
Black |
Silver |
|
|
Description |
Qty. |
Part Number |
Part Number |
|
|
|
|
|
|
|
|
|
|
A |
ball and socket mount |
1 |
055-0011 |
055-0016 |
|
|
|
|
|
|
|
|
|
B |
4 mm security allen wrench |
1 |
560-9646 |
560-9646 |
|
|
C |
M5 x .8 x 10 mm socket pin type F screw |
1 |
520-1164 |
520-2031 |
|
|
|
|
|
|
|
|
|
D |
#10-32 x 3/8" spade thumb screw |
1 |
560-1107 |
560-2107 |
|
|
E |
#10-32 x 3/8" serrated washer head socket pin screw |
1 |
520-1151 |
520-2151 |
|
|
|
|
|
|
|
|
|
F |
#14 x 2.5 phillips hex head wood screw |
2 |
5S1-015-C03 |
5S1-015-C04 |
|
|
G |
ceiling plate |
1 |
580-1042 |
580-4042 |
|
|
|
|
|
|
|
|
|
H |
.25" ID x .56" OD x .26 spacer |
2 |
590-1050 |
590-2071 |
|
|
I |
extension column connector with cord management |
1 |
580-1025 |
580-4025 |
|
|
|
|
|
|
|
|
|
J |
#10-32 x 3/8" socket pin screw |
2 |
520-1084 |
520-2084 |
|
|
K |
#10-32 x 3/16" slotted set screw |
3 |
520-1187 |
520-2187 |
|
C J E
A
I D H
K F
B
G
FASTENERS
Note: Actual parts may appear slightly different than illustrated.
2 of 7 |
ISSUED: 05-25-05 SHEET #: 055-9247-7 11-08-06 |
Visit the Peerless Web Site at www.peerlessmounts.com |
For customer care call 1-800-729-0307 or 708-865-8870. |
Installation To Wood Joist Finished Ceilings, Exposed Wood Joists, or Wood Beam Ceilings
Drill two 5/32" (4 mm) dia. holes to a minimum
depth of 2.5" (64 mm). Attach ceiling plate (G) with two #14 x 2.5" (6 mm x 65 mm) wood screws (F) as shown using 3/8" (10 mm) socket wrench.
Skip to step 2.
WARNING
•Tighten wood screws (F) so that wall plate (G) is firmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.
•Never tighten in excess of 80 in • lb (9 N.M.).
•Make sure that mounting screws are anchored into the center of the studs. The use of an "edge to edge" stud finder is highly recommended.
WARNING
•It is the responsibility of the installer to verify that the supporting surface will safely support the combined load of all attached hardware and components.
IMPORTANT: Be sure to drill holes into the joistCENTER!
WOOD
JOIST
CEILING
G
F
F
WOOD
JOIST
CEILING
H
H G
F F
For optional Cord Management, install two spacers (H) between ceiling plate (G) and ceiling.
3 of 7 |
ISSUED: 05-25-05 SHEET #: 055-9247-7 11-08-06 |
Visit the Peerless Web Site at www.peerlessmounts.com |
For customer care call 1-800-729-0307 or 708-865-8870. |