UL E193009 TUV R50020744 CB JPTUV-5363 CE MARK
• SINGLE OUTPUT UP TO 20A
DUAL OUTPUTS TOTAL CURRENT UP TO 15A UP TO 100% LOAD IMBALANCE
•INDUSTRY STANDARD FOOTPRINT
•ADJUSTABLE OUTPUT VOLTAGE, INDEPENDENTLY REGULATED OUTPUTS
•NO MINIMUM LOAD
•HIGH EFFICIENCY UP TO 90%
•COMPACT 2.40 X 2.28 X 0.50 INCH PACKAGE
•HALT TESTED
HEC75-SERIES DC/DC converters provide up to 75 watts of output power in an industry standard half-brick package and footprint. These units are specifically designed to meet the power needs of low-voltage silicon. All models feature a wide input range, trimmable output voltage and a 20A current rating (15A for dual output). Remote sense and remote on/off facilities are included as standard, and the converters are comprehensively protected against over-current, over-voltage and over-temperature conditions. The HEC75 converters are especially suited to telecom, networking and industrial application.
T E C H N I C A L S P E C I F I C AT I O N All specifications are typical at nominal input, full load and 25ºC otherwise noted
OUTPUT SPECIFICATIONS
Output power |
|
|
|
|
75 Watts max |
|
Voltage accuracy |
|
Full load and nominal Vin |
± 1.5% |
|||
|
|
|
|
|||
Voltage adjustability |
Single (Note 1) |
+ 10% , -20% |
||||
Dual |
|
|
+ 10% , -10% |
|||
|
|
|
|
|||
Minimum load |
|
|
|
|
0% |
|
|
|
|
|
|||
Line regulation |
|
LL to HL at FL |
See table |
|||
|
|
|
|
|||
Load regulation |
|
0% to 100% FL |
See table |
|||
|
|
|
|
|||
Remote sense |
|
Single (Note 1) |
10% of Vout |
|||
|
|
|||||
Ripple and noise 20MHz bandwidth (Note 2) |
100mVp-p |
|||||
|
|
|
|
|||
Temperature coefficient |
|
|
s0.02% / ºC, max |
|||
|
|
|||||
Transient response recovery time 25% load step change |
200uS |
|||||
|
|
|
|
|||
Over voltage protection threshold |
|
115% ~ 130% of Vout |
||||
(Non-latching Hiccup) |
|
|
||||
|
|
|
|
|||
Maximum total output current I 1 + I 2 |
Dual |
15A |
||||
|
|
|
||||
Over current protection threshold |
|
110% ~ 140% of Iout Rated |
||||
|
|
|
|
|||
Short circuit protection |
|
|
Hiccup, automatics recovery |
|||
|
|
|
|
|||
INPUT SPECIFICATIONS |
|
|
|
|||
Input voltage range |
|
|
|
36 – 75VDC |
||
|
|
|
|
|
||
UVLO start-up voltage |
|
|
|
34V typ. |
||
|
|
|
|
|
||
UVLO shuntdown voltage |
|
|
|
32V typ. |
||
|
|
|
|
|
||
Input filter (Note 3) |
|
|
|
L-C type |
||
|
|
|
|
|
|
|
Input voltage variation |
dv/dt |
|
|
5V/ms,max |
||
(Complies with ETS300 132 part 4.4) |
||||||
|
|
|
||||
Input surge voltage 100mS max |
|
|
100VDC |
|||
|
|
|
||||
Start up time |
Nominal Vin and constant resistive load |
25mS typ. |
||||
|
|
|
|
|||
Input reflected-ripple current |
|
|
20mAp-p |
|||
(5Hz to 20MHz, 12uH source impedance) |
||||||
|
||||||
Remote ON/OFF(Note4) |
|
|
|
|
||
(Positive logic) |
|
ON=Open or 3.5V < Vr < 15V, |
IIN=50 $ max. |
|||
|
|
OFF=Short or 0V < Vr < 1.2V, |
IIN=1m$ max. |
|||
(Negative logic) |
|
ON=Short or 0V < Vr < 1.2V, |
IIN=1m$ max. |
|||
|
|
OFF=Open or 3.5V < Vr < 15V, |
IIN=50 $ max. |
|
GENERAL SPECIFICATIONS |
|
|
||
|
Efficiency |
|
|
|
See table |
|
|
|
|
|
|
|
|
|
Input to Output |
|
1600 VDC, min. |
|
Isolation voltage |
|
Input to Case |
|
1000 VDC, min. |
|
|
|
Output to Case |
|
1000 VDC, min. |
|
Isolation resistance |
|
|
107 ohms, min |
|
|
Isolation capacitance |
|
|
2500 pF, max |
|
|
|
|
|
|
|
|
Switching frequency |
|
|
300 KHz, typ |
|
|
|
|
|||
|
Approvals and standard (Note 5) |
IEC60950, UL60950, EN60950 |
|||
|
|
|
|
|
|
|
Case material |
|
|
Open with Aluminum base-plate |
|
|
|
|
|
|
|
|
Weight |
|
Single |
|
53g (1.87oz) |
|
|
Dual |
|
57g (2.01oz) |
|
|
|
|
|
||
|
MTBF (Note 6) |
|
Single |
|
2 x 106 hrs |
|
|
Dual |
|
1.3 x 106 hrs |
|
|
|
|
|
||
|
ENVIRONMENTAL SPECIFICATIONS |
|
|||
|
Operating base-plate temperature range (Note 7) |
-40ºC to +100ºC |
|||
|
|
|
|
||
|
Over temperature protection |
|
110ºC |
||
|
|
|
|
||
|
Humidity max, Non-condensing |
|
95% |
||
|
|
|
|
||
|
Storage temperature range |
|
-55ºC to +125ºC |
||
|
|
|
|
|
|
|
Thermal shock |
|
|
|
MIL-STD-810D |
|
|
|
|||
|
Vibration |
10~55Hz, 2G, 3minutes period, 30minutes along X,Y and Z |
|||
|
|
|
|
||
|
EMC CHARACTERISTICS |
|
|
||
|
Conducted emissions |
EN55022 (Note 8) |
Level A |
||
|
EN55022 (Note 8) |
Level B |
|||
|
|
|
|||
|
Radiated emissions |
EN55022 |
|
Level A |
|
|
|
|
|
|
|
|
ESD |
|
EN61000-4-2 |
|
Perf. Criteria2 |
|
Radiated immunity |
EN61000-4-3 |
|
Perf. Criteria2 |
|
|
Fast transient |
|
EN61000-4-4 |
|
Perf. Criteria2 |
|
Surge |
|
EN61000-4-5 |
|
Perf. Criteria2 |
|
Conducted immunity |
EN61000-4-6 |
|
Perf. Criteria2 |