T E C H N I C A L S P E C I F I C AT I O N

3 WATTS REGULATED OUTPUT POWER

2:1 WIDE INPUT VOLTAGE RANGE

INTERNATIONAL SAFETY STANDARD APPROVAL

FIVE-SIDED SHIELD

HIGH EFFICIENCY UP TO 82%

STANDARD 24 PIN DIP PACKAGE & SMD TYPE PACKAGE

OVER CURRENT PROTECTION

The FKC03 series offer 3 watts of output power from a package in an IC compatible 24pin DIP configuration without derating to 71ºC ambient temperature and pin to pin compatible with FKC05 series. FKC03 series have 2:1 wide input voltage of 9-18, 18-36 and 36-75VDC. The FKC03 features 1600VDC of isolation, short-circuit protection and as well as five sided shielding. All models are particularly suited to telecommunications, industrial, mobile telecom and test equipment applications.

All specifications are typical at nominal input, full load and 25ºC otherwise noted

OUTPUT SPECIFICATIONS

Output power

 

 

 

3 Watts max

Voltage accuracy

 

Full load and nominal Vin

 

± 2%

Minimum load (Note 1)

 

 

10% of FL

 

 

 

 

 

Line regulation

 

LL to HL at Full Load

 

± 0.2%

 

 

 

 

 

Load regulation

 

25% to 100% FL

Single

± 0.2%

 

Dual

± 1%

 

 

 

Cross regulation(Dual)

Asymmetrical load 25% / 100% FL

± 5%

 

 

 

 

 

Ripple and noise

 

20MHz bandwidth

 

50mVp-p

 

 

 

Temperature coefficient

 

I0.02% / ºC, max

 

 

Transient response recovery time 25% load step change

200uS

 

 

 

 

Over load protection

% of FL at nominal input

 

180% typ

 

 

Short circuit protection

Continuous, automatics recovery

 

 

 

INPUT SPECIFICATIONS

 

 

Input voltage range

12V nominal input

 

9 – 18VDC

24V nominal input

 

18 – 36VDC

 

 

48V nominal input

 

36 – 75VDC

Input filter

 

 

 

Pi type

 

 

 

 

 

Input surge voltage

12V input

 

36VDC

24V input

 

50VDC

100mS max

 

 

 

48V input

 

100VDC

 

 

 

Input reflected ripple (Note 2) Nominal Vin and full load

20mAp-p

 

 

 

Start up time

Nominal Vin and constant resistor load

350mS typ

 

 

 

 

 

M1 Version

(%)

 

FKC03-48S05 Derating Curve

 

 

 

 

 

 

 

 

 

 

 

OUTPUT POWER

100

 

 

 

 

 

 

 

 

75

M! Version

 

 

 

 

 

 

 

50

 

 

 

 

 

 

 

25

Nature convection

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

0

50

60 70

80

90

100

 

-40 -25 -10

AMBIENT TEMPERATURE (ºC)

GENERAL SPECIFICATIONS

Efficiency

 

 

See table

 

Input to Output

 

1600VDC, min

Isolation voltage

Input(Output) to Case

DIP

1600VDC, min

 

 

SMD

1000VDC, min

Isolation resistance

 

 

109ohms, min

Isolation capacitance

 

 

300pF, max

 

 

 

 

Switching frequency

 

 

300KHz, typ

 

 

Approvals and standard

IEC60950, UL1950, EN60950

 

 

 

 

Case material

 

 

Nickel-coated copper

 

 

 

Base material

 

Non-conductive black plastic

 

 

 

 

Potting material

 

 

Epoxy (UL94-V0)

 

 

 

Dimensions

 

1.25 X 0.80 X 0.40 Inch

 

(31.8 X 20.3 X 10.2 mm)

 

 

Weight

DIP

 

16g (0.55oz)

SMD

 

18g (0.62oz)

 

 

MTBF (Note 3)

 

 

3.155 x 106 hrs

ENVIRONMENTAL SPECIFICATIONS

Operating temperature range

Standard

-25ºC~+85ºC (with derating)

M1 (Note 4)

-40ºC~+85ºC (non-derating)

 

 

 

Maximum case temperature

 

+100ºC

 

 

 

 

 

Storage temperature range

 

-55ºC ~ +105ºC

 

 

 

 

 

Thermal impedance

Nature convection

20ºC/watt

 

 

 

 

 

 

Thermal shock

 

 

MIL-STD-810D

 

 

 

 

 

Vibration

 

10~55Hz, 2G, 30minutes along X,Y and Z

 

 

 

 

 

 

Relative humidity

 

 

5% to 95% RH

 

 

 

 

EMC CHARACTERISTICS

 

 

Conducted emissions

EN55022

Level A

 

 

 

 

Radiated emissions

EN55022

Level A

 

 

 

 

 

 

 

ESD

EN61000-4-2

Perf. Criteria2

 

 

 

 

 

 

 

Radiated immunity

EN61000-4-3

Perf. Criteria2

 

 

 

 

 

 

 

Fast transient

EN61000-4-4

Perf. Criteria2

 

 

 

 

 

 

 

Surge

EN61000-4-5

Perf. Criteria2

 

 

 

 

 

 

 

Conducted immunity

EN61000-4-6

Perf. Criteria2

 

 

 

 

 

 

 