UL E193009
TUV R50009835 CB JPTUV-003843 CE MARK
Patent No.144566
•OFFER SINGLE, DUAL (TOTAL OUTPUT CURRENT 8A) AND TRIPLE OUTPUT
•40 WATTS MAXIMUM OUTPUT POWER
•2:1 WIDE INPUT VOLTAGE RANGE
•INTERNATIONAL SAFETY STANDARD APPROVAL
•SIX-SIDED CONTINUOUS SHIELD
•HIGH EFFICIENCY UP TO 90%
•STANDARD 2” x 2” x 0.4” PACKAGE
•FIXED SWITCHING FREQUENCY
The FEC40 series offer 40 watts of output power from a 2 x 2 x 0.4 inch package. The FEC40 series with 2:1 wide input voltage of 18-36VDC and 36-75VDC and features 1600VDC of isolation, short-circuit and over-voltage protection, as well as six sided shielding. All models are particularly suited to telecommunications, industrial, mobile telecom and test equipment applications.
T E C H N I C A L S P E C I F I C AT I O N All specifications are typical at nominal input, full load and 25ºC otherwise noted
OUTPUT SPECIFICATIONS
Output power |
|
|
|
|
|
40 Watts max |
|
|
|
|
|
Single / Dual |
|
± 1% |
|
Voltage accuracy FL and nominal Vin |
Triple |
Main |
|
± 1% |
|||
|
|
|
|
|
Auxiliary |
|
± 3% |
Voltage adjustability (Note 1) |
|
Single output only |
|
± 10% |
|||
|
|
|
|
|
|
|
|
Minimum load (Note 2) |
|
|
Single and Dual |
|
0% |
||
|
|
Triple |
|
10% of FL |
|||
|
|
|
|
|
|||
|
|
|
|
Single/Dual |
|
± 0.5% |
|
Line regulation LL to HL at Full Load |
|
Triple(main) |
|
± 1% |
|||
|
|
|
|
Triple(auxiliary) |
|
± 5% |
|
|
|
|
|
Single |
|
± 0.5% |
|
Load regulation |
10% to 100% FL |
|
Dual |
|
|
± 1% |
|
(Note 3) |
|
Triple |
Main |
|
± 2% |
||
|
|
|
|
||||
|
|
|
|
|
Auxiliary |
|
± 5% |
Load cross regulation |
|
|
Single/Dual/Triple(main) |
± 1% |
|||
(Note 4) |
|
|
|
Triple(auxiliary) |
|
± 5% |
|
Ripple and noise |
|
20MHz bandwidth |
|
See table |
|||
(Note 5) |
|
(Measured with a 104pF/50V MLCC) |
|||||
|
|
|
|||||
Temperature coefficient |
|
|
|
s0.02% / ºC, max |
|||
|
|
|
|
||||
Transient response recovery time |
25% load step change |
|
400uS |
||||
|
|
|
|
|
|
|
|
Over voltage protection |
3.3V output |
|
|
|
|
3.9V |
|
5V output |
|
|
|
|
6.2V |
||
Zener diode clamp |
|
12V output |
|
|
|
|
15V |
|
|
15V output |
|
|
|
|
18V |
Over load protection |
% of FL at nominal input |
150% max |
|||||
|
|
|
|
|
|||
Short circuit protection |
|
|
|
Hiccup, automatics recovery |
INPUT SPECIFICATIONS
Input voltage range |
|
24V nominal input |
18 – 36VDC |
||
|
48V nominal input |
36 – 75VDC |
|||
|
|
||||
|
|
24V input |
DC-DC ON |
17.8VDC |
|
Under voltage lockout |
|
DC-DC OFF |
16VDC |
||
|
|
||||
|
48V input |
DC-DC ON |
36VDC |
||
|
|
||||
|
|
DC-DC OFF |
34VDC |
||
|
|
|
|||
Input filter (Note 6) |
|
|
|
L-C type |
|
|
|
|
|
|
|
Input voltage variation |
dv/dt |
|
|
5V/ms,max |
|
(Complies with ETS300 132 part 4.4) |
|||||
|
|
||||
Input surge voltage |
|
24V input |
|
50VDC |
|
100mS max |
|
48V input |
|
100VDC |
|
Input reflected ripple (Note 7) Nominal Vin and full load |
40mAp-p |
||||
|
|
||||
Start up time Nominal Vin and constant resistor load |
25mS typ |
||||
|
|
|
|
||
Remote ON/OFF (Note 8) |
|
|
|
||
|
DC-DC ON |
Open or 3.5V < Vr < 12V |
|||
Remote off input current |
DC-DC OFF |
Short or 0V < Vr < 1.2V |
|||
Nominal Vin |
|
2.5mA |
GENERAL SPECIFICATIONS
Efficiency |
|
|
See table |
|
Isolation voltage |
|
|
1600VDC, min |
|
|
|
|
|
|
Isolation resistance |
|
|
109ohms, min |
|
Isolation capacitance |
|
|
1000pF, max |
|
|
|
|
||
Switching frequency (Note 9) |
|
300KHz, typ |
||
|
|
|
||
Approvals and standard |
|
IEC60950, UL1950, EN60950 |
||
|
|
|
||
Case material |
|
Nickel-coated copper |
||
|
|
|
||
Base material |
|
Non-conductive black FR4 |
||
|
|
|
|
|
Potting material |
|
|
Epoxy (UL94-V0) |
|
|
|
|
||
Dimensions |
|
2.00 X 2.00 X 0.40 Inch |
||
|
(50.8 X 50.8 X 10.2 mm) |
|||
|
|
|||
Weight |
|
|
60g (2.11oz) |
|
|
|
|
|
|
MTBF (Note 10) |
|
|
1.398 x 106 hrs |
|
ENVIRONMENTAL SPECIFICATIONS |
|
|||
Operating temperature range |
-40ºC ~ +85ºC (with derating) |
|||
|
|
|
|
|
Maximum case temperature |
|
|
100ºC |
|
|
|
|
|
|
Storage temperature range |
|
|
-55ºC ~ +105ºC |
|
|
|
|
|
|
Over temperature protection |
|
|
115ºC, typ |
|
|
|
|
||
Thermal impedance |
Nature convection |
9.2ºC/Watt |
||
Heat-sink with 20LFM |
8.5ºC/Watt |
|||
(Note 11) |
||||
Heat-sink with 500LFM |
2.8ºC/Watt |
|||
|
||||
Thermal shock |
|
|
MIL-STD-810D |
|
|
|
|||
Vibration |
10~55Hz, 2G, 30minutes along X,Y and Z |
|||
|
|
|
|
|
Relative humidity |
|
|
5% to 95% RH |
|
|
|
|
||
EMC CHARACTERISTICS |
|
|
||
Conducted emissions |
EN55022 |
|
Level A |
|
|
|
|
|
|
Radiated emissions |
EN55022 |
|
Level A |
|
|
|
|
|
|
ESD |
EN61000-4-2 |
|
Perf. Criteria2 |
|
|
|
|
|
|
Radiated immunity |
EN61000-4-3 |
|
Perf. Criteria2 |
|
|
|
|
|
|
Fast transient |
EN61000-4-4 |
|
Perf. Criteria2 |
|
|
|
|
|
|
Surge |
EN61000-4-5 |
|
Perf. Criteria2 |
|
|
|
|
|
|
Conducted immunity |
EN61000-4-6 |
|
Perf. Criteria2 |
|
|
|
|
|