Panasonic WV-Q151S, WV-Q151C User Manual

Before attempting to connect or operate this product,
please read these instructions carefully and save this manual for future use.
No model number suffix is shown in this manual.
Ceiling Mount Bracket
Operating Instructions
Model Nos.
WV-Q151C/WV-Q151S
3
If a selected area is too weak to support the total weight, a fall of the product may occur resulting in injury. Installation work shall be started after sufficient reinforcement.
• Periodic inspections shall be conducted.
Rust on the metal parts or screws may cause a fall of the product resulting in injury. Consult the dealer for the inspections.
• Do not rub the edges of metal parts with your hand.
Failure to observe this may cause injury.
• Consult the dealer about the installation area to select a strong ceiling area. Make sure that the installation area is strong enough to hold the total weight of the camera assembly (approx. 1.7 kg {3.6 lbs.}) before installation.
• The installation area shall have 180 mm {7-1/8"} or more space behind the ceiling.
• The thickness of the ceiling board for installation can range between 9 mm {3/8"} and 40 mm {1-9/16"}.
• Avoid installing in the following locations.
• Locations where it may get wet from rain or water splash (not only outdoor)
• Locations where a chemical agent is used such as a swimming pool
• Locations subject to steam and oil smoke such as a kitchen
• Locations near flammable gas or vapor
• Locations where radiation or x-ray emissions are produced
• Locations subject to strong magnetic field or radio waves
• Locations where it may be damaged by briny air such as seashores
• Locations where the temperature is not within –10 °C - +50 °C {14 °F - 122 °F}.
• Locations subject to vibrations (This product is not designed for on-vehicle use.)
• Locations where the temperature may rapidly change such as the peripheral areas of the air outlets of air conditioners or doors facing outside. (In case of installing the cam­era in such locations, the dome cover may become foggy or condensation may be caused on the cover.)
• The screws and bolts must be tightened with an appropriate tightening torque according to the material and strength of the installation area. After tightening the screws or bolts, per­form visual check to ensure tightening is enough and there is no backlash.
• The pull-out strength of the installation area shall be 196 N {20 kgf} or more per 1 screw.
• The protection sheet attached to the dome cover shall be peeled off after installation.
180 mm {7-1/8"} or more
Ceiling board: between 9 mm {3/8"} and 40 mm {1-9/16"}
2
CONTENTS
Preface ....................................................................................................................................... 2
Precautions ................................................................................................................................ 2
Major Operating Controls and Their Functions .......................................................................... 4
Installations ................................................................................................................................ 5
Specifications ................................................................................................................ back cover
Standard Accessories ................................................................................................... back cover
Precautions
• Refer installation work to the dealer.
Installation work requires technique and experiences. Failure to observe this may cause fire, electric shock, injury, or damage to the product. Be sure to consult the dealer.
• Avoid installing this bracket in the locations where salt damage occurs or corrosive gas is produced.
Otherwise, the mounting portions will deteriorate and accidents such as a fall of the camera may occur.
• Use only the specified camera.
Failure to observe this may cause a fall of an inappropriate camera resulting in injury or accidents. Mount WV-NS202 on this bracket exclusively.
• The screws and fixation mechanisms shall be tightened securely.
Failure to observe this may cause a fall of the camera resulting in injury.
• The measures of protection against a fall of the camera shall be taken.
Failure to observe this may cause injury. Be sure to install the safety wire.
Preface
This ceiling mount bracket is exclusively designed to mount the network camera, WV-NS202, on a ceiling. This bracket can be used for an area with weak pull-out strength such as plasterboard in a double ceiling. This bracket is an embedded type to reduce the exposed portion of the camera body.
• WV-Q151C: Clear dome cover
• WV-Q151S: Smoked dome cover (approx. 50 % of transmittance)
5
4
Installations
Be sure to read "Precautions" on the page xx before installation. The Installation Guide of the network camera, WV-NS202, shall be read as well.
1. Remove the decorative cover.
q Loosen the fixing screw (unremov-
able) to be used for cover fall pre­vention.
w Unhook the decorative cover from
the hooks (3 positions) of the cam­era mounting plate and remove the decorative cover by turning it coun­terclockwise.
e Take the inner shell out.
2. Remove the camera mounting plate.
Remove the screws (M4, 3 positions) and remove the camera mounting plate by turning it counterclockwise. Disengage the portion (a) from the hole (b) (2 positions).
Fixing screw to be used for cover fall prevention
Hook
(b)
Camera mount­ing plate
Screw (M4)
(a)
Major Operating Controls and Their Functions
Decorative cover
Microphone stand*
Fixing screw to be used for cover fall prevention
Camera mounting plate
Mounting base
Hole for microphone cable
Dome cover
Safety wire angle (Accessory)
Safety wire (Accessory)
Ceiling mount bracket
Decorative cover
WV-NS202
Dome cover
Ceiling board
Roof space
* If a microphone is used, mount the microphone on the rubber-made microphone stand.
Unless the microphone is used, cut the rubber with a nipper or conduct another treatment.
<Installation sample>
Inner shell
FRONT
K
C
O
L
T
N
O
R
F
K
C
O
L
T
N
O
FRONT
R
F
Loading...
+ 4 hidden pages