Panasonic Wj-Ms424 User Manual

Quad Unit
WJ-MS424
Before attempting to connect or operate this product, please read these instructions completely
ENGLISH
DEUTSCH
FRANÇAIS
ESPAÑOL
Model No. Serial No.
THIS APPARATUS MUST BE EARTHED.
To ensure safe operation the three-pin plug supplied must be insert­ed only into a standard three-pin power point which is effectively earthed through the normal household wiring. Extension cords used with the equipment must be three-core and be correctly wired to pro­vide connection to earth. Wrongly wired extension cords are a major cause of fatalities. The fact that the equipment operates satisfactorily does not imply that the power point is earthed and that the installation is completely safe. For your safety, if in any doubt about the effective earthing of the power point, consult a qualified electrician.
The lightning flash with arrowhead sym­bol, within an equilateral triangle, is interned to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilat­eral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appli­ance.
WARNING:
TO PREVENT FIRE OR ELECTRIC SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOIS
TURE.
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK), NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
For Australia
FOR YOUR SAFETY PLEASE READ THE FOLLOWING TEXT CARE­FULLY.
This appliance is supplied with a moulded three pin mains plug for your safety and convenience. A 13 amp fuse is fitted in this plug. Should the fuse need to be replaced please ensure that the replacement fuse has a rating of 13 amp and that it is approved by ASTA or BSI to BS1362. Check for the ASTA mark
H or the BSI mark G on the body of the
fuse. If the plug contains a removable fuse cover you must ensure that it is refitted when the fuse is replaced. If you lose the fuse cover the plug must not be used until a replacement cover is obtained. A replacement fuse cover can be purchased from your local Panasonic Dealer.
IF THE FITTED MOULDED PLUG IS UNSUITABLE FOR THE SOCK­ET OUTLET IN YOUR HOME THEN THE FUSE SHOULD BE REMOVED AND THE PLUG CUT OFF AND DISPOSED OF SAFELY. THERE IS A DANGER OF SEVERE ELECTRICAL SHOCK IF THE CUT OFF PLUG IS INSERTED INTO ANY 13 AMP SOCKET.
If a new plug is to be fitted please observe the wiring code as shown below. If in any doubt please consult a qualified electrician.
WARNING: This apparatus must be earthed.
IMPORTANT
The wires in this mains lead are coloured in accordance with the follow­ing code.
Green-and-yellow: Earth Blue: Neutral Brown: Live
As the colours of the wire in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows.
The wire which is coloured green-and-yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol
I or coloured green or green-and-yellow.
The wire which is coloured blue must be connected to the terminal in the plug which is marked with the letter N or coloured black.
The wire which is coloured brown must be connected to the terminal in the plug which is marked with the letter L or coloured red.
How to replace the fuse
Open the fuse compartment with a screwdriver and replace the fuse and fuse cover.
For U.K.

ENGLISH VERSION

CAUTION:
Before attempting to connect or operate this prod­uct, please read the label on the bottom.
-1-
CONTENTS
PREFACE .................................................................................................................................................................................. 2
FEATURES ................................................................................................................................................................................ 2
PRECAUTIONS ......................................................................................................................................................................... 2
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS ................................................................................................... 3
RACK MOUNTING .................................................................................................................................................................... 5
SETTING UP THE MENUS ........................................................................................................................................................ 6
SYSTEM CONNECTIONS ....................................................................................................................................................... 12
SPECIFICATIONS ................................................................................................................................................................... 16
STANDARD ACCESSORIES ................................................................................................................................................... 16
Wij verklaren als enige aansprakelijke, dat het product waarop deze verklaring betrekking heeft, voldoet aan de volgende normen of andere normatiefve dokumenten, overeenkomstig de bepalingen van Richtlijnen 73/23/EEC en 89/336/EEC.
Vi erklærer os eneansvarlige for, at dette produkt, som denne deklaration omhandler, er i overensstemmelse med den følgende standarder eller andre normative dokumenter i følge bestem­melserne i direktivene 73/23/EEC og 89/336/EEC.
Vi deklarerar härmed värt fulla ansvar för att den produkt till vilken denna deklaration hänvisar är i överensstämmelse med standard­dokument, eller andra normativa dokument som framstölls i Direktiv 73/23/EEC och 89/336/EEC.
Ilmoitamme yksinomaisella vastuullamme, että tuote, jota tämä ilmoitus koskee, noudattaa seuraavia standardeja tai muita ohjeel­lisia asiakirjoja, jotka noudattavat direktiivien 73/23/EEC ia 89/336/EEC. säädöksiä.
Vi erklærer oss alene ansvarlige for at produktet som denne erklæringen gjelder for, er i overensstemmelse med følgende normer eller andre normgivende dokumenter som fælger bestem­melsene i direktiven 73/23/EEC og 89/336/EEC.
We declare under our sole responsibility that the product to which this declaration relates is in conformity with the standards or other normative documents following the provisions of Directives EEC/73/23 and EEC/89/336.
Nosotros declaramos bajo nuestra única responsabilidad que el producto a que hace referencia esta declaración està conforme con las normas u otros documentos normativos siguiendo las estipula­ciones de la directivas CEE/73/23 y CEE/89/336.
Noi dichiariamo sotto nostra esclusiva responsabilità che il prodotto a cui si riferisce la presente dichiarazione risulta conforme ai seguenti standard o altri documenti normativi conformi alle dispo­sizioni delle direttive CEE/73/23 e CEE/89/336.
Wir erklären in alleiniger Verantwortung, daß das Produkt, auf das sich diese Erklärung bezieht, mit der folgenden Normen oder nor­mativen Dokumenten übereinstimmt. Gemäß den Bestimmungen der Richtlinite 73/23/EEC und 89/336/EEC.
ENGLISH
-2-
The Panasonic WJ-MS424 Quad Unit is ideal for CCTV applications where multiple surveillance cameras are required. Most 2 : 1 interlace cameras available today, either colour or black and white, are compatible with the WJ-MS424. Up to four cameras may be connected to
PREFACE
1. Compatible with Most 2 : 1 Interlace cameras Advanced digital processing technology allows connection of most 2 : 1 interlace cameras available today without the requirement for synchronization of the four video inputs. The system may be added to existing security sys­tems and makes possible displays in black and white or full colour.
2. Alphanumeric Character Generator Title insertion of up to 8 characters in each of the four windows is possible. This promotes easy identi­fication of the separate camera locations.
3. Alarm with Built-in Buzzer This system can be combined with alarm sensors and switches as well as time-lapse VTRs through the alarm output and reset signal connectors. Upon receiving an alarm signal, a full-sized picture of the site is displayed. By setting the “CAM TITLE ON” and “ALARM TITLE ON” modes from the TITLE menu, “ALARM” and the window title will appear intermittently in the picture. The Automatic alarm reset time is adjustable from 1 to 30 sec.,1, 2, 3, 4, 5 min. or Off.
FEATURES
PRECAUTIONS
• Do not attempt to disassemble the unit. In order to prevent electrical shock, do not remove screws or covers. There are no user-serviceable parts inside.
• Do not abuse the unit. Avoid striking, shaking etc. It could be damaged by improper handling or stor­age.
• Do not use strong or abrasive detergents when cleaning the unit body.
• Do not expose the unit to water or moisture, and do not operate it in wet or humid areas.
• Do not use the unit in an extreme environment where high temperature or high humidity exists.
• Handle the unit with care.
• Take immediate action if ever the unit does become wet. Tune the power off and refer servicing to quali­fied service personnel. Moisture can damage the unit and also create a danger of electric shock.
• Use the unit under conditions where temperature is within –10°C to +50°C (14°F to 122°F), and humidity is below 90%. When installing the unit in the rack, it is recommended to install the fan.
• The input power source is 220 - 240 V AC, 50 Hz.
• Refer all installation work to qualified service per­sonnel or system installers.
4. Quad Picture Borderlines A white borderline can be inserted in the quad pic­tures by setting “BORDER ON” from the Setup Menu.
5. Two kinds of Video Output Connectors The Quad system offers two kinds of video output connectors : (a) VIDEO OUT : Quad or full-size single picture
can be selected with the front panel switches.
(b) VTR OUT : A quad display is always supplied,
regardless of the setting of the front panel switches.
6. A back-up memory inside maintains preset title character information.
7. Video Loss Checking Function If the video signal is lost due to a disconnected cable or other reasons, an alarm buzzer beeps and a caution message is displayed on the monitor screen.
the system, and if desired, the monitor can be divided into 4 windows for simultaneous display of the four dif­ferent images. Simple front panel switch operation allows quick selec­tion between quad and single camera display modes.
-3-
1. Power ON/OFF Switch (POWER)
This switch turns the power of this switch on or off. The POWER indicator lights when the power of this unit is on.
Switch Protector (Standard Accessory)
To prevent that the power of this unit is turned off acci­dentally, install the supplied switch protector as shown below.
• QUAD button
When QUAD is selected for VIDEO OUT on the SYSTEM SETUP menu, this button works as the QUAD button. Pressing this button displays the quad picture on the monitor screen.
• SEQ button
When SEQ is selected for VIDEO OUT on the SYS­TEM SETUP menu, this button works as the SEQ button. Pressing this button displays the pictures on the monitor screen in the sequential order and with the dwell time set on the SEQ SETUP menu.
• ESC button
When the setup menu (SYSTEM SETUP, SEQ SETUP, TITLE SETUP, TITLE SET or TITLE POSI) is displayed on the monitor screen, this button works as the ESC button.
Pressing this button returns the current setup menu to the previous setup menu.
4. VIDEO SELECT (1, 2, 3, 4)/CURSOR (4, 5)/SELECT(–, +) Buttons
These buttons select the video signal or move the cursor on the setup menus.
• VIDEO SELECT(1, 2, 3, 4) buttons
When the setup menu is not displayed, these but­tons work as VIDEO SELECT buttons. Pressing one of these buttons selects a channel to be displayed in single picture mode.
• CURSOR (4, 5)/SELECT(–, +) buttons
When the setup menu is displayed, these buttons work as CURSOR (4, 5)/SELECT (–, +) buttons. Pressing these buttons moves the cursor or select s a mode or a parameter.

MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS

2. Alarm LED (ALARM)
This LED flashes while the alarm signal is received. It changes to steady light when the alarm is reset automatically. To turn the flashing LED off, press the ALARM RESET/QUAD/SEQ button.
3. Alarm Reset/Quad/Sequence/Escape Button (ALARM RESET/QUAD/SEQ/ESC)
This button has different functions in different modes, as described below.
• ALARM RESET button
When an alarm signal is received, this button works as the ALARM RESET button. Pressing this button in an alarm situation cancels the alarm mode with the following results:
1. The alarm LED stops flashing.
2. The alarm output is stopped.
3. The alarm buzzer stops beeping.
4. The video loss caution message on the monitor screen disappears and the screen returns to the camera picture.
ALARM RESET
QUAD/SEQ
POWER
ALARM
ESC
4
3
INOUT
INOUT
VIDEO
1 2 3 4
2
INOUT
POWER ON OFF
PROTECTION
SWITCH
PROTECTOR
VIDEO SELECT
CURSOR SELECT
1
INOUT
MENU
+
VTR
VIDEO
OUT
ALARM/REMOTE
OUT
Quad System WJ-MS
SIGNAL GND
-4-
4 button: This button moves the cursor to the left or
selects an item on the setup menus.
5 button: This button moves the cursor to the right
or selects an item on the setup menus.
– button: This button selects a character or a para-
meter on the setup menus.
+ button: This button selects a character or a para-
meter on the setup menus.
5. Menu Button (MENU)
Pressing this button for approx. 2 seconds displays the setup menus. Pressing it again for approx. 1 second cancels the display of the setup menus.
6. Video input Connector (VIDEO IN 1, 2, 3, 4)
These connectors receive a composite video signal. They are automatically terminated.
Notes:
• The input signals must meet the CCIR B/W video signal standard, if the video inputs of this unit are to be synchronized.
• If the input signals have a high jitter content, as in the case of a VTR playback picture, it may not be possible to synchronize this unit.
13251224112310229218207196185174163152141
Not Used
Not Used
ALARM OUT
Not Used
ALARM RESET OUT
ALARM RECOVER IN QUAD/SEQ
Menu
Selector
REMOTE/ALARM 4
REMOTE/ALARM 3
REMOTE/ALARM 2
REMOTE/ALARM 1
GND
Pin-14 to 25 are connected to Ground
7. Video Output Connectors (VIDEO OUT 1, 2, 3, 4)
The video input signals connected to the VIDEO IN connector are looped through to these connectors.
Connectors a coaxial cable to these connectors cancels the termination.
8. VTR Output Connector (VTR OUT)
The video signal for the quad picture mode is always provided at this connector. By connecting it to the VIDEO IN connector of the time lapse VTR, you can record the quad picture.
9. Video Output Connector (VIDEO OUT)
The video signal selected by the QUAD/SEQ button (quad picture) or the VIDEO SELECT button (single picture) is output from this connector.
10. Alarm/Remote Control Connector (ALARM/REMOTE)
This connector accepts the alarm signal from asso­ciated alarm sensor units and the remote control signal from the external equipment.
Caution: The input voltage should be DC 24V or
less for ALARM IN.
11. Power Cord
Loading...