Panasonic Wj-Ms424 User Manual

Page 1
Quad Unit
WJ-MS424
Before attempting to connect or operate this product, please read these instructions completely
ENGLISH
DEUTSCH
FRANÇAIS
ESPAÑOL
Page 2
Model No. Serial No.
THIS APPARATUS MUST BE EARTHED.
To ensure safe operation the three-pin plug supplied must be insert­ed only into a standard three-pin power point which is effectively earthed through the normal household wiring. Extension cords used with the equipment must be three-core and be correctly wired to pro­vide connection to earth. Wrongly wired extension cords are a major cause of fatalities. The fact that the equipment operates satisfactorily does not imply that the power point is earthed and that the installation is completely safe. For your safety, if in any doubt about the effective earthing of the power point, consult a qualified electrician.
The lightning flash with arrowhead sym­bol, within an equilateral triangle, is interned to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilat­eral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appli­ance.
WARNING:
TO PREVENT FIRE OR ELECTRIC SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOIS
TURE.
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK), NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
For Australia
FOR YOUR SAFETY PLEASE READ THE FOLLOWING TEXT CARE­FULLY.
This appliance is supplied with a moulded three pin mains plug for your safety and convenience. A 13 amp fuse is fitted in this plug. Should the fuse need to be replaced please ensure that the replacement fuse has a rating of 13 amp and that it is approved by ASTA or BSI to BS1362. Check for the ASTA mark
H or the BSI mark G on the body of the
fuse. If the plug contains a removable fuse cover you must ensure that it is refitted when the fuse is replaced. If you lose the fuse cover the plug must not be used until a replacement cover is obtained. A replacement fuse cover can be purchased from your local Panasonic Dealer.
IF THE FITTED MOULDED PLUG IS UNSUITABLE FOR THE SOCK­ET OUTLET IN YOUR HOME THEN THE FUSE SHOULD BE REMOVED AND THE PLUG CUT OFF AND DISPOSED OF SAFELY. THERE IS A DANGER OF SEVERE ELECTRICAL SHOCK IF THE CUT OFF PLUG IS INSERTED INTO ANY 13 AMP SOCKET.
If a new plug is to be fitted please observe the wiring code as shown below. If in any doubt please consult a qualified electrician.
WARNING: This apparatus must be earthed.
IMPORTANT
The wires in this mains lead are coloured in accordance with the follow­ing code.
Green-and-yellow: Earth Blue: Neutral Brown: Live
As the colours of the wire in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows.
The wire which is coloured green-and-yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol
I or coloured green or green-and-yellow.
The wire which is coloured blue must be connected to the terminal in the plug which is marked with the letter N or coloured black.
The wire which is coloured brown must be connected to the terminal in the plug which is marked with the letter L or coloured red.
How to replace the fuse
Open the fuse compartment with a screwdriver and replace the fuse and fuse cover.
For U.K.

ENGLISH VERSION

CAUTION:
Before attempting to connect or operate this prod­uct, please read the label on the bottom.
Page 3
-1-
CONTENTS
PREFACE .................................................................................................................................................................................. 2
FEATURES ................................................................................................................................................................................ 2
PRECAUTIONS ......................................................................................................................................................................... 2
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS ................................................................................................... 3
RACK MOUNTING .................................................................................................................................................................... 5
SETTING UP THE MENUS ........................................................................................................................................................ 6
SYSTEM CONNECTIONS ....................................................................................................................................................... 12
SPECIFICATIONS ................................................................................................................................................................... 16
STANDARD ACCESSORIES ................................................................................................................................................... 16
Wij verklaren als enige aansprakelijke, dat het product waarop deze verklaring betrekking heeft, voldoet aan de volgende normen of andere normatiefve dokumenten, overeenkomstig de bepalingen van Richtlijnen 73/23/EEC en 89/336/EEC.
Vi erklærer os eneansvarlige for, at dette produkt, som denne deklaration omhandler, er i overensstemmelse med den følgende standarder eller andre normative dokumenter i følge bestem­melserne i direktivene 73/23/EEC og 89/336/EEC.
Vi deklarerar härmed värt fulla ansvar för att den produkt till vilken denna deklaration hänvisar är i överensstämmelse med standard­dokument, eller andra normativa dokument som framstölls i Direktiv 73/23/EEC och 89/336/EEC.
Ilmoitamme yksinomaisella vastuullamme, että tuote, jota tämä ilmoitus koskee, noudattaa seuraavia standardeja tai muita ohjeel­lisia asiakirjoja, jotka noudattavat direktiivien 73/23/EEC ia 89/336/EEC. säädöksiä.
Vi erklærer oss alene ansvarlige for at produktet som denne erklæringen gjelder for, er i overensstemmelse med følgende normer eller andre normgivende dokumenter som fælger bestem­melsene i direktiven 73/23/EEC og 89/336/EEC.
We declare under our sole responsibility that the product to which this declaration relates is in conformity with the standards or other normative documents following the provisions of Directives EEC/73/23 and EEC/89/336.
Nosotros declaramos bajo nuestra única responsabilidad que el producto a que hace referencia esta declaración està conforme con las normas u otros documentos normativos siguiendo las estipula­ciones de la directivas CEE/73/23 y CEE/89/336.
Noi dichiariamo sotto nostra esclusiva responsabilità che il prodotto a cui si riferisce la presente dichiarazione risulta conforme ai seguenti standard o altri documenti normativi conformi alle dispo­sizioni delle direttive CEE/73/23 e CEE/89/336.
Wir erklären in alleiniger Verantwortung, daß das Produkt, auf das sich diese Erklärung bezieht, mit der folgenden Normen oder nor­mativen Dokumenten übereinstimmt. Gemäß den Bestimmungen der Richtlinite 73/23/EEC und 89/336/EEC.
ENGLISH
Page 4
-2-
The Panasonic WJ-MS424 Quad Unit is ideal for CCTV applications where multiple surveillance cameras are required. Most 2 : 1 interlace cameras available today, either colour or black and white, are compatible with the WJ-MS424. Up to four cameras may be connected to
PREFACE
1. Compatible with Most 2 : 1 Interlace cameras Advanced digital processing technology allows connection of most 2 : 1 interlace cameras available today without the requirement for synchronization of the four video inputs. The system may be added to existing security sys­tems and makes possible displays in black and white or full colour.
2. Alphanumeric Character Generator Title insertion of up to 8 characters in each of the four windows is possible. This promotes easy identi­fication of the separate camera locations.
3. Alarm with Built-in Buzzer This system can be combined with alarm sensors and switches as well as time-lapse VTRs through the alarm output and reset signal connectors. Upon receiving an alarm signal, a full-sized picture of the site is displayed. By setting the “CAM TITLE ON” and “ALARM TITLE ON” modes from the TITLE menu, “ALARM” and the window title will appear intermittently in the picture. The Automatic alarm reset time is adjustable from 1 to 30 sec.,1, 2, 3, 4, 5 min. or Off.
FEATURES
PRECAUTIONS
• Do not attempt to disassemble the unit. In order to prevent electrical shock, do not remove screws or covers. There are no user-serviceable parts inside.
• Do not abuse the unit. Avoid striking, shaking etc. It could be damaged by improper handling or stor­age.
• Do not use strong or abrasive detergents when cleaning the unit body.
• Do not expose the unit to water or moisture, and do not operate it in wet or humid areas.
• Do not use the unit in an extreme environment where high temperature or high humidity exists.
• Handle the unit with care.
• Take immediate action if ever the unit does become wet. Tune the power off and refer servicing to quali­fied service personnel. Moisture can damage the unit and also create a danger of electric shock.
• Use the unit under conditions where temperature is within –10°C to +50°C (14°F to 122°F), and humidity is below 90%. When installing the unit in the rack, it is recommended to install the fan.
• The input power source is 220 - 240 V AC, 50 Hz.
• Refer all installation work to qualified service per­sonnel or system installers.
4. Quad Picture Borderlines A white borderline can be inserted in the quad pic­tures by setting “BORDER ON” from the Setup Menu.
5. Two kinds of Video Output Connectors The Quad system offers two kinds of video output connectors : (a) VIDEO OUT : Quad or full-size single picture
can be selected with the front panel switches.
(b) VTR OUT : A quad display is always supplied,
regardless of the setting of the front panel switches.
6. A back-up memory inside maintains preset title character information.
7. Video Loss Checking Function If the video signal is lost due to a disconnected cable or other reasons, an alarm buzzer beeps and a caution message is displayed on the monitor screen.
the system, and if desired, the monitor can be divided into 4 windows for simultaneous display of the four dif­ferent images. Simple front panel switch operation allows quick selec­tion between quad and single camera display modes.
Page 5
-3-
1. Power ON/OFF Switch (POWER)
This switch turns the power of this switch on or off. The POWER indicator lights when the power of this unit is on.
Switch Protector (Standard Accessory)
To prevent that the power of this unit is turned off acci­dentally, install the supplied switch protector as shown below.
• QUAD button
When QUAD is selected for VIDEO OUT on the SYSTEM SETUP menu, this button works as the QUAD button. Pressing this button displays the quad picture on the monitor screen.
• SEQ button
When SEQ is selected for VIDEO OUT on the SYS­TEM SETUP menu, this button works as the SEQ button. Pressing this button displays the pictures on the monitor screen in the sequential order and with the dwell time set on the SEQ SETUP menu.
• ESC button
When the setup menu (SYSTEM SETUP, SEQ SETUP, TITLE SETUP, TITLE SET or TITLE POSI) is displayed on the monitor screen, this button works as the ESC button.
Pressing this button returns the current setup menu to the previous setup menu.
4. VIDEO SELECT (1, 2, 3, 4)/CURSOR (4, 5)/SELECT(–, +) Buttons
These buttons select the video signal or move the cursor on the setup menus.
• VIDEO SELECT(1, 2, 3, 4) buttons
When the setup menu is not displayed, these but­tons work as VIDEO SELECT buttons. Pressing one of these buttons selects a channel to be displayed in single picture mode.
• CURSOR (4, 5)/SELECT(–, +) buttons
When the setup menu is displayed, these buttons work as CURSOR (4, 5)/SELECT (–, +) buttons. Pressing these buttons moves the cursor or select s a mode or a parameter.

MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS

2. Alarm LED (ALARM)
This LED flashes while the alarm signal is received. It changes to steady light when the alarm is reset automatically. To turn the flashing LED off, press the ALARM RESET/QUAD/SEQ button.
3. Alarm Reset/Quad/Sequence/Escape Button (ALARM RESET/QUAD/SEQ/ESC)
This button has different functions in different modes, as described below.
• ALARM RESET button
When an alarm signal is received, this button works as the ALARM RESET button. Pressing this button in an alarm situation cancels the alarm mode with the following results:
1. The alarm LED stops flashing.
2. The alarm output is stopped.
3. The alarm buzzer stops beeping.
4. The video loss caution message on the monitor screen disappears and the screen returns to the camera picture.
ALARM RESET
QUAD/SEQ
POWER
ALARM
ESC
4
3
INOUT
INOUT
VIDEO
1 2 3 4
2
INOUT
POWER ON OFF
PROTECTION
SWITCH
PROTECTOR
VIDEO SELECT
CURSOR SELECT
1
INOUT
MENU
+
VTR
VIDEO
OUT
ALARM/REMOTE
OUT
Quad System WJ-MS
SIGNAL GND
Page 6
-4-
4 button: This button moves the cursor to the left or
selects an item on the setup menus.
5 button: This button moves the cursor to the right
or selects an item on the setup menus.
– button: This button selects a character or a para-
meter on the setup menus.
+ button: This button selects a character or a para-
meter on the setup menus.
5. Menu Button (MENU)
Pressing this button for approx. 2 seconds displays the setup menus. Pressing it again for approx. 1 second cancels the display of the setup menus.
6. Video input Connector (VIDEO IN 1, 2, 3, 4)
These connectors receive a composite video signal. They are automatically terminated.
Notes:
• The input signals must meet the CCIR B/W video signal standard, if the video inputs of this unit are to be synchronized.
• If the input signals have a high jitter content, as in the case of a VTR playback picture, it may not be possible to synchronize this unit.
13251224112310229218207196185174163152141
Not Used
Not Used
ALARM OUT
Not Used
ALARM RESET OUT
ALARM RECOVER IN QUAD/SEQ
Menu
Selector
REMOTE/ALARM 4
REMOTE/ALARM 3
REMOTE/ALARM 2
REMOTE/ALARM 1
GND
Pin-14 to 25 are connected to Ground
7. Video Output Connectors (VIDEO OUT 1, 2, 3, 4)
The video input signals connected to the VIDEO IN connector are looped through to these connectors.
Connectors a coaxial cable to these connectors cancels the termination.
8. VTR Output Connector (VTR OUT)
The video signal for the quad picture mode is always provided at this connector. By connecting it to the VIDEO IN connector of the time lapse VTR, you can record the quad picture.
9. Video Output Connector (VIDEO OUT)
The video signal selected by the QUAD/SEQ button (quad picture) or the VIDEO SELECT button (single picture) is output from this connector.
10. Alarm/Remote Control Connector (ALARM/REMOTE)
This connector accepts the alarm signal from asso­ciated alarm sensor units and the remote control signal from the external equipment.
Caution: The input voltage should be DC 24V or
less for ALARM IN.
11. Power Cord
Page 7
-5-
To install the WJ-MS424 Quad Unit in an EIA 19-inch rack, use the rack mounting brackets (provided) and eight screws (provided, M3x10).
1. Turn off the power of the unit.
2. Remove the four screws fixing the rubber legs, and remove the four rubber legs from the unit.

RACK MOUNTING

Remove four rubber legs.
3. Attach the rack mounting brackets on both sides and fix them with eight screws (provided).
Eight screws (Provided)
4. Install the unit in the rack with four screws (to be procured locally).
Cautions:
1. Leave one space free both above and below the unit, or install a cooling fan in the rack.
2. If the rack is subject to vibrations, secure the rear of the unit to the rack using additional rack mounting brackets (to be procured locally).
EIA 19” rack
Fix the rack mounting brackets
Page 8
ALARM
MENU
ESC
ALARM RESET
QUAD/SEQ
1 2 3 4
VIDEO SELECT
CURSOR SELECT
+
** MAIN **
SYSTEM SETUP
* ALARM BUZZER 2SEC ALARM OUT 2SEC ALARM AUTO RESET OFF SEQ SETUP
*
TITLE SETUP
*
-6-
Before the Settings
1. Confirm that the cameras and peripherals are con­nected correctly and firmly.
2. Turn on the power of this unit and connected peripherals.

1. Displaying the Menus

Press the MENU button for 2 seconds or more.
The MAIN menu appears.
You can setup the following items:
• SYSTEM SETUP
• ALARM BUZZER
• ALARM OUT
• ALARM AUTO RESET
• SEQ SETUP
• TITLE SETUP
See the following pages for details about the func­tions and settings.

2. How to Operate the Menus

To select the desired item, press the CURSOR (4,
5) buttons. Each time you press a button, the cur- sor moves to the next (5) or previous (4) item.

SETTING UP THE MENUS

To select the desired parameter of the selected item, press the SELECT (–, +) buttons.
3 4
+
Note:
Some items have a setting menu (The
“*”
mark indicates that a setting menu exists, for exam­ple, SYSTEM SETUP.), press the SELECT (–, +) buttons to select ON for its parameter. The set­ting menu of the selected item appears.
Precaution:
Entering the setup menu is not possible while the ALARM LED is flashing. Make sure the alarm mode is canceled. To cancel the alarm mode, press the ALARM RESET button.
All Reset Operation
All reset allows you to reset all setup menu items to the factory settings if you are unsure about the cor­rect settings. Proceed as follows:
1. Turn the power of this unit off.
2. Keep holding down the CURSOR button (5), the SELECT button (+), and the MENU button simultaneously, and press the POWER button. The buzzer beeps when all settings are reset to the factory settings.
1 2
Page 9
-7-
3-1-1. Border (BORDER)
This parameter lets you set the appearance of the bor­ders that divide the screen.
1. Move the cursor to BORDER.
2. Select ON or OFF. ON: The borders appear when QUAD is selected
for VIDEO OUT.
OFF: The borders do not appear.
ALARM
MENU
ESC
ALARM RESET
QUAD/SEQ
1 2 3 4
VIDEO SELECT
CURSOR SELECT
+
or
** SYSTEM SETUP **
BORDER ON VIDEO OUT QUAD AUTO SKIP OFF VIDEO LOSS ON
Borderline (white)
e
3-1-2. Quad/Sequence (VIDEO OUT)
This parameter lets you select the quad picture or sequential single picture for display on the monitor screen.
1. Move the cursor to VIDEO OUT.
2. Select QUAD or SEQ. QUAD: The quad picture appears on the monitor
that is connected to the VIDEO OUT connector.
SEQ: The single picture appears sequentially in
the order to set on the of SEQUENCE SETUP submenu of the MAIN menu.
** SYSTEM SETUP **
BORDER ON VIDEO OUT QUAD AUTO SKIP OFF VIDEO LOSS ON

3. Setup Menu Description

3-1. SYSTEM SETUP
The SYSTEM menu lets you set the following items:
• BORDER
• VIDEO OUT
• AUTO SKIP
• VIDEO LOSS
1. Move the cursor to SYSTEM SETUP.
2. Press one of the SELECT buttons (– or +). The SYS­TEM SETUP menu appears on the monitor screen. Note: To return to the MAIN menu, press the ESC
button.
ALARM
MENU
ESC
ALARM RESET
QUAD/SEQ
1 2 3 4
VIDEO SELECT
CURSOR SELECT
+
** SYSTEM SETUP **
BORDER ON VIDEO OUT QUAD AUTO SKIP OFF VIDEO LOSS ON
or
ALARM
ALARM RESET
QUAD/SEQ
ESC
** SYSTEM SETUP **
BORDER ON VIDEO OUT QUAD AUTO SKIP OFF VIDEO LOSS ON
VIDEO SELECT
1 2 3 4
CURSOR SELECT
or
MENU
+
Page 10
-8-
** SYSTEM SETUP **
BORDER ON VIDEO OUT QUAD AUTO SKIP OFF VIDEO LOSS ON
** SYSTEM SETUP **
BORDER ON VIDEO OUT QUAD AUTO SKIP ON VIDEO LOSS ON
1
2
3
4
1
3
4
d
3-1-3. Auto Channel Skipping (AUTO SKIP)
Setting
This parameter lets you set automatic skipping of chan­nels to which no camera is connected.
1. Move the cursor to AUTO SKIP.
2. Select ON or OFF.
ON: Channels to which no camera is connected are
skipped when SEQ is selected.
OFF: No channels are skipped.
** MAIN **
SYSTEM SETUP
* ALARM BUZZER 2SEC ALARM OUT 2SEC ALARM AUTO RESET OFF SEQ SETUP
*
TITLE SETUP
*
OFF 1SEC 2SEC
......
30SEC
1MIN
......
5MIN EXT
3-2. ALARM BUZZER
This parameter lets you adjust the buzzer time between 1 and 30 seconds and 1 and 5 minutes.
1. Move the cursor to ALARM BUZZER.
2. Select the buzzer time. OFF: The alarm buzzer does not beep when an
alarm signal is received.
1-30 SEC, 1-5 MIN: The buzzer keeps on beeping
for the duration you set.
EXT: The alarm buzzer keeps on beeping until an
operation is performed from an external equip­ment such as a time lapse VTR.
3-1-4. Video Loss Checking (VIDEO LOSS)
This parameter lets you activate a function that checks whether the video signal is being supplied to the VIDEO INPUT connector.
1. Move the cursor to VIDEO LOSS.
2. Select ON or OFF.
OFF: The video loss alarm is ignored. ON: When video loss alarm is received, the picture
switches to the quad format. The message “CHXX LOSS” appears on the monitor screen and the alarm buzzer starts beeping.
** SYSTEM SETUP **
BORDER ON VIDEO OUT QUAD AUTO SKIP OFF VIDEO LOSS OFF
Page 11
-9-
3-3. ALARM OUT
This parameter lets you adjust the duration the alarm signal is output between 1 and 30 seconds and 1 and 5 minutes.
1. Move the cursor to ALARM OUT.
2. Select the duration the alarm signal is output. 1-30 SEC, 1-5 MIN: The alarm signal is output for
the duration you set.
** MAIN**
SYSTEM SETUP
*
ALARM BUZZER 2SEC ALARM OUT 2SEC ALARM AUTO RESET OFF SEQ SETUP
*
TITLE SETUP
*
1SEC
......
30SEC 1MIN
......
5MIN
3-4. ALARM AUTO RESET
This parameter lets you set the time until the unit recov­ers after receiving the alarm signal.
1. Move the cursor to ALARM AUTO RESET.
2. Select the recover time. OFF: The alarm condition is maintained until the
ALARM RESET button on the front panel is pressed or the alarm recover signal from the time lapse VTR is supplied to the ALARM/ REMOTE connector.
1-30 SEC, 1-5 MIN: The alarm condition is main-
tained for the length of the recover time you set.
** MAIN **
SYSTEM SETUP
* ALARM BUZZER 2SEC ALARM OUT 2SEC ALARM AUTO RESET OFF SEQ SETUP
*
TITLE SETUP
*
OFF 1SEC
......
30SEC 1MIN
......
5MIN
3-5. SEQ SETUP
This parameter lets you set the sequential order and dwell time for camera switching.
1. Move the cursor to SEQ SETUP.
2. Press one of the SELECT buttons (– or +). The SEQUENCE menu appears on the monitor screen, and “1 CH” starts blinking.
ALARM
MENU
ESC
ALARM RESET
QUAD/SEQ
1 2 3 4
VIDEO SELECT
CURSOR SELECT
+
** MAIN **
SYSTEM SETUP
* ALARM BUZZER 2SEC ALARM OUT 2SEC ALARM AUTO RESET OFF SEQ SETUP
*
TITLE SETUP
*
** SEQ SETUP **
1: 1CH 2SEC 2: 2CH 2SEC 3: 3CH 2SEC 4: 4CH 2SEC 5: OFF 6: OFF 7: OFF 8: OFF
or
3. Press the SELECT buttons (–, +) to select the chan­nel. The channel changes as below:
** SEQUENCE **
1: 1CH 2SEC 2: 2CH 2SEC 3: 3CH 2SEC 4: 4CH 2SEC 5: OFF 6: OFF 7: OFF 8: OFF
: Cursor Move
<Channel>
4. Press the CURSOR buttons (4 or 5) so that “SEC” starts blinking. The cursor moves in the SEQ SETUP menu as shown below:
1CH 2CH 3CH
4CH QUAD OFF
<Display time>
5. Select the dwell time by pressing the SELECT buttons (–, +). The dwell time changes as below:
1SEC 2SEC 3SEC • • • • 30SEC
6. Repeat steps 3 to 5 to determine the sequential order and dwell time.
7. Press the ESC button to return to the MAIN menu.
Page 12
-10-
3-6. TITLE SETUP
A title consisting of up to 8 alphanumeric characters can be displayed on the monitor.
1. Move the cursor to TITLE SETUP.
2. Press one of the SELECT buttons (– or +). The TITLE SETUP menu appears on the monitor screen.
or
ALARM
MENU
ESC
ALARM RESET
QUAD/SEQ
1 2 3 4
VIDEO SELECT
CURSOR SELECT
+
** TITLE SETUP **
CAM TITLE ON TITLE SET
*
TITLE POSI
*
ALARM TITLE ON
** MAIN **
SYSTEM SETUP
*
ALARM BUZZER 2SEC ALARM OUT 2SEC ALARM AUTO RESET OFF SEQ SETUP
*
TITLE SETUP
*
You can set the following items:
• CAM TITLE
• TITLE SET
• TITLE POSI
• ALARM TITLE
Note: To return to the MAIN menu, press the ESC
button.
3-6-1. CAM TITLE
This parameter lets you decide whether or not to have the title displayed.
1. Move the cursor to the CAM TITLE parameter.
2. Select ON or OFF.
ON: Title display. OFF: No title display.
3-6-2. TITLE SET
This parameter lets you edit a displayed title.
1. Move the cursor to TITLE SET.
2. Press one of the SELECT buttons (– or +). The EDITTING menu appears on the monitor screen and “1” starts blinking.
3. Move the cursor to the channel number whose title is to be edited by pressing the CURSOR buttons (4 or 5).
4. Select a character by pressing the SELECT buttons (– or +).
5. After selecting the first character, press the CUR­SOR button(5). Then select the second character.
6. Repeat steps 3 to 5 above to complete the title.
7. Repeat steps 3 to 6 to edit the other channels.
8. Press the ESC button to return to the previous menu.
or
1....... 2.......
3....... 4.......
ABCDEFGHIJKLM NOPQRSTUVWXYZ ДЬЦЖСЕШ 0123456789 ←→=?'"#&()*+,
-./:;
E
(blank)
ALARM
MENU
ESC
ALARM RESET
QUAD/SEQ
1 2 3 4
VIDEO SELECT
CURSOR SELECT
+
** TITLE SETUP **
CAM TITLE ON TITLE SET
*
TITLE POSI
* ALARM TITLE ON TITLE EDIT ON
** TITLE SETUP **
CAM TITLE ON TITLE SET
*
TITLE POSI
*
ALARM TITLE ON
ABCDEFGH
Page 13
-11-
To erase a specific character
1. Select a character to be erased.
2. Select “•” (blank mark) to erase the character.
To erase the title of a specific channel
1. Move the cursor to the channel number whose title is to be erased.
2. Press the SELECT buttons (– and +) simultaneous­ly.
3-6-3. TITLE POSI
This parameter lets you select the position on the moni­tor screen where you want the title to be displayed.
1. Move the cursor to TITLE POSI.
2. Press one of the SELECT buttons (– or +). The TITLE POSITION menu appears with the title of the channel 1 on the monitor screen.
3. Select the position where the title is to be displayed by pressing the CURSOR buttons (
4 or 5).
4. Press the ESC button to return to the previous menu.
1.......
** TITLE SETUP **
CAM TITLE ON TITLE SET
*
TITLE POSI
*
ALARM TITLE OFF
Note: All channel titles will be displayed in the
same position. You cannot specify a different position for each title.
3-6-4. ALARM TITLE
This parameter lets you decide whether or not to have the word”ALARM” displayed when the unit receives the alarm signal.
1. Move the cursor to ALARM TITLE .
2. Select ON or OFF.
ON: “ALARM” is displayed OFF: “ALARM” is not displayed.
** TITLE SETUP **
CAM TITLE ON TITLE SET
*
TITLE POSI
*
ALARM TITLE ON
ALARM
Page 14
-12-

SYSTEM 1

The input video signals for this unit are not synchronized.
Notes :
• When pressing the ALARM RESET/QUAD/SEQ/ECS button or the VIDEO SELECT/CURSOR/SELECT buttons, the pic­ture on the video monitor may roll briefly at the time of switching.
• The video signal to be recorded by the VTR should be supplied from the VTR OUT connector of this unit and not from the VIDEO OUT/ESC connector of this unit, unless VTR servo control disturbances are allowable when setting the ALARM RESET/ QUAD/SEQ/ECS button or the VIDEO SELECT/CURSOR/SELECT buttons.
Connections
• Connect the VIDEO IN connectors of this unit to the video output connectors of the cameras.
• Connect the VTR OUT connector of this unit to the video input connector of the time lapse VTR for recording.
• Connect the VIDEO OUT connector of this unit to the video input connector of the video monitor.
VTR OUT
1
VIDEO
OUT
ALARM/REMOTE
INOUT
2
VIDEO
INOUT
3
INOUT
4
INOUT
SIGNAL GND
Monitor
Monitor
VTR
WJ-MS424
VIDEO
VIDEO
VIDEO
VIDEO

SYSTEM CONNECTIONS

Page 15
-13-

SYSTEM 2

The input video signals for this unit are synchronized, and synchronization noise or disturbances in the video output signal will not occur when the quad or single picture mode is selected.
Connections
• Connect the VIDEO IN connectors of this unit to the video output connectors of the cameras.
• Connect the VTR OUT connector of this unit to the video input connector of the video distribution amplifier (V.D.A).
• Connect the output of the video distribution amplifier (V.D.A.) to the video input connector of the time lapse VTR and to the gen-lock input connectors of the cameras.
• Connect the VIDEO OUT connector of this unit to the video input connector of the monitor.
VTR OUT
1
VIDEO
OUT
ALARM/REMOTE
INOUT
2
VIDEO
INOUT
3
INOUT
4
INOUT
SIGNAL GND
Monitor
Monitor
VTR
VDA
VIDEO
WJ-MS424
GENLOCK
GENLOCK GENLOCK
GENLOCK
VIDEO
VIDEO
VIDEO
Page 16
-14-
VTR OUT
1
VIDEO
OUT
ALARM/REMOTE
INOUT
2
VIDEO
INOUT
3
INOUT
4
INOUT
SIGNAL GND
IN
CAMERA
OUT
VIDEO
OUT
AUDIO
4ch
IN
CAMERA
OUT
VIDEO
OUT
AUDIO
3ch
IN
CAMERA
OUT
VIDEO
OUT
AUDIO
2ch
IN
CAMERA
OUT
VIDEO
OUT
AUDIO
1ch
IN
VD/SYNC
OUT
VD/SYNC
(4Vp-p 75)
CAUTION
Monitor
Monitor
VTR
VIDEO
WJ-MS424
WV-PS104C

SYSTEM 3

A system consisting of this Quad Unit and the specified cameras should include the WV-PS104C Camera Drive Unit.
Note: When pressing the ALARM RESET/QUAD/SEQ/ESC button or the VIDEO SELECT/CURSOR/SELECT buttons, the pic-
ture on the video monitor may roll briefly at the time of switching.
Connections
• Connect the VIDEO IN connectors of this unit to the video output connectors of the WV-PS104C Camera Drive Unit.
• Connect the VIDEO OUT connector of this unit to the video input connector of the monitor.
• Connect the VTR OUT connector of this unit to the video input connector of the time lapse VTR.
• Connect the video output connectors of the cameras to the camera input connectors of the WV-PS104C Camera Drive Unit.
Page 17
-15-

SYSTEM 4

Connections
• Connect the VIDEO IN connectors of this unit to the video output connectors of the cameras.
• Connect the VTR OUT connector of this unit to the input connector of the time lapse VTR.
• Connect the VIDEO OUT connector of this unit to the input connector of the monitor.
• Connect the wires of the alarm sensors to the alarm input pins of ALARM/REMOTE connector.
• Connect the ALARM OUTPUT pin of the ALARM/REMOTE connector of this unit to the alarm input terminal of the time lapse VTR.
• Connect the recover output (alarm reset output) of the time lapse VTR to the ALARM RECOVER IN pin of the ALARM/ REMOTE connector of this unit.
• Connect the ALARM RESET OUT pin of the ALARM/REMOTE connector of this unit to the alarm reset in terminal of the time lapse VTR.
VTR OUT
1
VIDEO
OUT
ALARM/REMOTE
INOUT
2
VIDEO
INOUT
3
INOUT
4
INOUT
SIGNAL GND
Monitor
Monitor
VTR
Sensor
WJ-MS424
Sensor
Sensor
Sensor
Page 18
-16-
Video Input : 2:1 interlace, composite 1V [p-p] 75 , auto termination or loop-through, black and white or
colour video signal x 4 (Each video signal should be synchronized vertically for vertical interval switching. Does not have to be synchronized in case vertical interval switching is not required.)
Video Output : Video Output x 1, composite, 1V [p-p] 75 , colour or black and white video signal with com-
posite sync and burst signal. Title : Up to 8 characters per window Alarm Input : One per 4 video inputs (max. DC 12V and a make-contact for ground) Alarm Output : One (max. DC 24V, 100mA, open collector circuit) Alarm Time : Adjustable approx. 1s to 30s, 1, 2, 3, 4, 5 min. or EXT Recover Input : One (max. DC 12V and a make-contact for ground) Auto Reset Time : Adjustable approx. 1s to 30s, 1, 2, 3, 4, 5 min. or OFF Ambient Operating Temperature : 10˚C to +50˚C (14˚F to 122˚F) Power Source and
Power Consumption: 220 - 240V AC, 50Hz, 14W
Dimensions : 420 (W) x 44 (H) x 350 (D) mm
[16-1/2” (W) x 1-3/4” (H) x 13-3/4” (D)] Weight : 3.6 kg (7.9 lbs.)
Weight and Dimensions shown above are approximate. Specifications are subject to change without notice.

SPECIFICATIONS

STANDARD ACCESSORIES

Rack Mounting Brackets ................................................1 set
Rack Mounting Bracket Fixing Screws ..........................8 pcs
Switch Protector .............................................................1 pc
Page 19
Matsushita Electric Industrial Co., Ltd.
Central P.O. Box 288, Osaka 530-91, Japan
N0398-1048 YWV8QA4909BN Printed in Japan
N 30 Gedruckt in Japan
Imprimé au Japon Impreso en Japón
Loading...