Panasonic WHADC0309G3E5UK Operating Instructions

Air-to-Water Hydromodule + Tank
Model No.
Indoor Unit
WH-ADC0309G3E5UK
Outdoor Unit
WH-UD03EE5 WH-UD05EE5 WH-UD07FE5 WH-UD09FE5
Operating Instructions Air-to-Water Hydromodule + Tank
Installation Instructions attached. Serial number and production year please refer to name plate.
English
Manufactured by: Panasonic Appliances Air-Conditioning Malaysia Sdn. Bhd. Lot 2, Persiaran Tengku Ampuan, Section 21, Shah Alam Industrial Site, 40300 Shah Alam, Selangor Darul Ehsan, Malaysia.
F569829
Thank you for purchasing Panasonic product.
Before operating the system, read these operating instructions thoroughly and keep them for future reference.
Table of contents
Safety precautions ………………………………………… 3-5 To adjust initial settings …………………………………… 6-7 How to use ……………………………………………… 8-11 Cleaning instructions ……………………………………… 12 Troubleshooting …………………………………………13-14 Information ………………………………………………… 15
The illustrations in this manual are for explanation purposes only and may differ from the actual unit. They are subject to change without notice for future improvement.
System overview
Open and Close Top Front Plate
Do not open or close the Top Front Plate by excessive force.
To Open: To Close:
Top Front Plate
open
“click”
Before use, make sure the system has been installed correctly by an authorised dealer according to the given instructions.
Panasonic Air-to-Water is a split system, consisting of two units: indoor and outdoor units. The indoor unit consist of the hydromodule and 200L sanitary water tank.
• These operating instructions describe how to operate the system using the indoor and outdoor units.
• As for the operation of other products such as radiator, external thermo controller, and underfloor units, refer to the operating instructions of each product.
• System could be locked to operate in HEAT mode and disable COOL mode.
• Some functions described in this manual may not be applicable to your system.
• Consult your nearest authorised dealer for further information.
1
*
The system is locked to operate without COOL mode.
It can be unlocked only by authorised installers or our authorised service partners. *2 Only displayed when COOL mode is unlocked (Means when COOL mode is available).
Bottom Front Plate
“click”
Control panel
“click”
Hold in position
Note:
Not recommended to open the Bottom Front Plate. (For authorised dealer/ specialist use only)
Operating conditions
HEATING
(TANK)
Water outlet temperature (°C)
(Min. / Max.)
Outdoor ambient temperature (°C)
(Min. / Max.)
* Above 55 °C, only possible with backup heater operation.
- / 65* 25 / 55 5 / 20
2
close
Power Supply Radiator
HEATING
(CIRCUIT)
-20 / 35 16 / 43
COOLING (CIRCUIT)
Floor HeatingOutdoor Unit
Fan Coil Unit
Indoor Unit
When the outdoor temperature is out of the range in the table, the heating capacity will drop significantly and the outdoor unit may stop operating for its protection. The unit will restart automatically after the outdoor temperature returns to the specified range.
Shower
Safety precautions
To prevent personal injury, injury to others or property damage, please comply with the following: Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classified as below:
This sign warns of
WARNING
death or serious injury.
This sign warns of
CAUTION
injury or damage to property.
The instructions to be followed are classified by the following symbols:
This symbol denotes an action that is PROHIBITED.
These symbols denote actions COMPULSORY.
WARNING
Indoor unit and outdoor unit
This appliance may be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Please consult an authorised dealer or specialist to clean the internal parts, repair, install, remove and reinstall the unit. Improper installation and handling will cause leakage, electric shock or fire.
Safety precautions
Confirm with an authorised dealer or specialist on usage of any specified refrigerant type. Using refrigerant type other than the specified may cause product damage, burst and injury etc.
When open the Top Front Plate, make sure it is securely hold in position. Else it may fall and cause injury.
English
3
Safety precautions
Do not install the unit in a potentially explosive or flammable atmosphere. Failure to do so could result in fire.
Do not insert your fingers or other objects into the indoor or outdoor unit; the rotating parts may cause injury.
Do not touch the outdoor unit during lightning, it may cause an electric shock.
Do not sit or step on the unit, you may fall down accidentally.
Do not install the indoor unit outdoors. This is designed for indoor installation only.
Power supply
Do not use a modified cord, joint cord, extension cord or unspecified cord to prevent overheating and fire.
To prevent overheating, fire or electric shock:
• Do not share the same power outlet with other equipment.
• Do not operate with wet hands.
• Do not bend or twist power supply cord.
If the supply cord is damaged, it must be replaced by the manufacturer, service agent or similarly qualified persons in order to avoid a hazard.
This unit is equipped with Residual Current Circuit Breaker/Earth Leakage Circuit Breaker (RCCB/ELCB). Ask an authorised dealer to check RCCB/ELCB operation regularly, especially after installation, inspection, and maintenance. RCCB/ELCB malfunction may result in electric shock and/or fire.
It is strongly recommended that Install Residual Current Device (RCD) on-site to prevent electric shock and/or fire.
Before obtaining access to terminals, all supply circuits must be disconnected.
Stop using the product if any abnormality/failure occurs and disconnect the power supply. (Risk of smoke/fire/electric shock) Examples of abnormality/failure
• RCCB/ELCB trips frequently.
• Burning smell is observed.
• Abnormal noise or vibration of the unit is observed.
• Hot water leaks from the indoor unit.
Contact your local dealer immediately for maintenance/ repair.
Wear gloves during inspection and maintenance.
4
This equipment must be earthed to prevent electrical shock or fire.
Prevent electric shock by disconnecting the power supply
- Before cleaning or servicing.
- When extended non-use. This appliance is for multiple
uses. To avoid electric shock, burn and/or fatal injury, make sure to disconnect all power supplies before accessing any terminal in the indoor unit.
Prevent water leakage by ensuring that the drainage pipe is connected properly.
After a long period of use, make sure the installation rack is not deteriorated. The deteriorated rack may cause the unit to fall down.
Ask an authorised dealer to determine the level of sterilisation function field settings according to the local laws and regulations.
CAUTION
Indoor unit and outdoor unit
Do not wash the indoor unit with water, benzine, thinner or scouring powder to avoid damage or corrosion on the unit.
Do not install the unit close to any combustibles or at bathroom. Otherwise, it may cause electric shock and/or fire.
Do not touch the water discharge pipe of the indoor unit during operation.
Do not place any material on the unit or under it.
Do not touch the sharp aluminium fin; sharp parts may cause injury.
Do not use the system during sterilisation in order to prevent scalding with hot water, or overheating of shower.
Control panel
Do not wet the control panel. Failure to do so may result in electric shock and/or fire.
Do not press the buttons on the control panel using hard and sharp objects. Failure to do so may cause damage to the unit.
Do not wash the control panel using water, benzine, thinner or scouring powder.
Do not inspect or maintain the control panel by yourself. Consult an authorised dealer in order to prevent personal injury caused by incorrect operation.