ORDER No. SM-99042
Colour Television
TX-28MK1P/M
TX-21MK1P/M
EURO-4 Chassis
SPECIFICATIONS
(Information in brackets {} refers to model TX-21MK1P/M)
Power Source: 220-240V a.c., 50Hz
Power Consumption: 130W {115W}
Stand-by Power
Consumption: 1,8W
Aerial Impedance: 75Ω unbalanced, Coaxial Type
Receiving System: PAL B/G, H, D/K, PAL-525/60
SECAM B/G, D/K
M.NTSC
NTSC (AV only)
Receiving Channels:
VHF E2-E12 VHF H1-H2 (ITALY)
VHF A-H (ITALY) VHF R1-R2
VHF R3-R5 VHF R6-R12
UHF E21-E69 CATV (S01-S05)
CATV S1-S10 (M1-M10) CATV S11-S20 (U1-U10)
CATV S21-S41 (HYPERBAND)
Intermediate Frequency:
Video/Audio
Video 38,9MHz
Audio 33,16MHz, 33,4MHz
32,4MHz (A2 Stereo)
33,05MHz (NICAM)
32,66MHz, 32,4MHz (Czech Stereo)
Colour 34,47MHz (PAL)
34,5MHz, 34,65MHz (SECAM)
Terminals:
AUDIO MONITOR OUT Audio (RCAx2) 500mV rms 1kΩ
AV1 IN Video (21 pin) 1V p-p 75Ω
Audio (21 pin) 500mV rms 10kΩ
RGB (21 pin)
AV2 IN Video (21 pin) 1V p-p 75Ω
Audio (21 pin) 500mV rms 10kΩ
S-Video IN Y: 1V p-p 75Ω
(21-pin) C:0,3V p-p 75Ω
AV2 OUT Video (21 pin) 1V p-p 75Ω
Audio (21 pin) 500mV rms 1kΩ
Selectable output (21 pin)
AV3 IN Audio (RCAx2) 500mV rms 10kΩ
Video (RCAx1) 1V p-p 75Ω
High Voltage: 28,2kV ±1kV {28kV ±1kV}
Picture Tube: A66ECF50X42 66cm
{A51EER35X70 51cm}
Audio Output: 2 x 15W (Music Power)
8Ω Impedance
Headphones: 8Ω Impedance
3,5 mm
Accessories
supplied : Remote Control
2 x R6 (UM3) Batteries
Dimensions:
Height: 580mm {481mm}
Width: 666mm {525mm}
Depth: 472mm {477mm}
Net weight: 31kg {22kg}
Specifications are subject to change without notice.
Weights and dimensions shown are approximate.
NOTE: This Service Manual should be used in conjunction with
the EURO-4 Technical guide.
AV1 OUT Video (21 pin) 1V p-p 75Ω
Audio (21 pin) 500mV rms 1kΩ
CONTENTS
SAFETY PRECAUTIONS..........................................................................................................................................................2
SERVICE HINTS.......................................................................................................................................................................3
ADJUSTMENT PROCEDURE AND SELF-CHECK ..................................................................................................................4
WAVEFORM PATTERN TABLE...............................................................................................................................................5
ALIGNMENT SETTINGS...........................................................................................................................................................6
BLOCK DIAGRAMS..................................................................................................................................................................7
PARTS LOCATION.................................................................................................................................................................11
REPLACEMENT PARTS LIST................................................................................................................................................12
SCHEMATIC DIAGRAMS.......................................................................................................................................................23
CONDUCTOR VIEWS.............................................................................................................................................................28
SAFETY PRECAUTION
GENERAL GUIDE LINES
1. It is advisable to insert an isolation transformer in the
a.c. supply before servicing a hot chassis.
2. When servicing, observe the original lead dress in the
high voltage circuits. If a short circuit is found, replace
all parts that have been overheated or damaged by
the short circuit.
3. After servicing, see that all the protective devices
such as insulation barriers, insulation papers, shields
and isolation R-C combinations are correctly
installed.
4. When the receiver is not being used for a long period
of time, unplug the power cord from the a.c. outlet.
5. Potentials as high as 29,2kV {29kV} are present
when this receiver is in operation. Operation of the
receiver without the rear cover involves the danger of
a shock hazard from the receiver power supply.
Servicing should not be attempted by anyone who is
not familiar with the precautions necessary when
working on high voltage equipment. Always
discharge the anode of the tube.
6. After servicing make the following leakage current
checks to prevent the customer from being exposed
to shock hazard.
LEAKAGE CURRENT COLD CHECK
1. Unplug the a.c. cord and connect a jumper between
the two prongs of the plug.
2. Turn on the receiver’s power switch.
3. Measure the resistance value with an ohmmeter,
between the jumpered a.c. plug and each exposed
metallic cabinet part on the receiver, such as screw
heads, aerials, connectors, control shafts etc. When
the exposed metallic part has a return path to the
chassis, the reading should be between 4M ohm and
20M ohm. When the exposed metal does not have a
return path to the chassis, the reading must be
infinite.
LEAKAGE CURRENT HOT CHECK
1. Plug the a.c. cord directly into the a.c. outlet. Do not
use an isolation transformer for this check.
2. Connect a 2kΩ 10W resistor in series with an
exposed metallic part on the receiver and an earth,
such as a water pipe.
3. Use an a.c. voltmeter with high impedance to
measure the potential across the resistor.
4. Check each exposed metallic part and check the
voltage at each point.
5. Reverse the a.c. plug at the outlet and repeat each of
the previous measurements.
6. The potential at any point should not exceed
1,4 Vrms. In case a measurement is outside the limits
specified, there is a possibility of a shock hazard, and
the receiver should be repaired and rechecked before
it is returned to the customer.
HOT CHECK CIRCUIT
a.c. VOLTMETER
2kΩ 10 Watts
TO INSTRUMENT’S EXPOSED
METALLIC PARTS
Fig. 1.
X-RADIATION WARNING
1. The potential sources of X-Radiation in TV sets are
the high voltage section and the picture tube.
2. When using a picture tube test jig for service, ensure
that the jig is capable of handling 29,2kV {29kV}
without causing X-Radiation.
NOTE: It is important to use an accurate periodically
calibrated high voltage meter.
1. Set the brightness to minimum.
2. Measure the high voltage. The meter should indicate.
TX-28MK1P/M 28,2kV± 1kV.
TX-21MK1P/M 28kV ± 1kV.
If the meter indication is out of tolerance, immediate
service and correction is required to prevent the
possibility of premature component failure.
3. To prevent any X-Radiation possibility, it is essential
to use the specified tube.
WATER PIPE
(
EARTH)
2
SERVICE HINTS
How to remove the rear cover
1. Remove the 9 screws as shown in Fig.2.
LOCATION OF CONTROLS
SCREWS
Fig.2.
E-BOARD
H-BOARD
Fig.3.
FOCUS
SCREEN
Y-BOARD
3
ADJUSTMENT PROCEDURE
Item / Preparation Adjustments
+B SET-UP
1. Receive a Greyscale signal.
2. Set the controls :Brightness Minimum
Contrast Minimum
Volume Minimum
CUT OFF / Ug2 Test
1. Receive a Greyscale signal.
2. Degauss the tube externally.
3. Set the TV into Service Mode 1.
4. Select Cut off mode.
1. Set the +B voltage up as follows:Adjust R811 so that B2 shows 148V±1V [130V±1V
TX-21MK1P/M]
2. Confirm the following voltages.
B9 5 ± 0,25V B10 5 ± 0,25V
B5 12 ± 0,5V B11 33 ± 1,5V
B4 16 ± 1V B7 8 ± 0,5V
B12 26 ± 1V B8 5,5 ± 0,5V
B3 35 ± 1V B13 15 ± 1V
B1 200 ± 10V B14 -15 ± 1V
To adjust Cutoff connect an oscilloscope to the Blue
cathode, adjust "cutoff" value using the "Yellow" and "Blue"
buttons until the black level is 160V±5V press "STR" to store
the value. Remove the oscilloscope.
Select Ug2 adjustment and adjust the screen VR until the
display shows "O.K."
SELF CHECK
Self-check is used to automatically check the bus lines and hexadecimal code of the TV set.To enter Self-Check mode. press
the down (-/v) button on the customer controls at the front of the TV set, at the same time pressing the STATUS button
on the remote control. To exit Self Check, switch off the TV set at the power button.
VDP O.K.
TUN O.K.
E2 O.K.
PCB O.K.
Cab O.K.
Sum
Factory use only
MSP O.K.
--
OPTION 1 3D{3D}
OPTION 2 0C{0E}
OPTION 3 1F {1F}
OPTION 4 00 {00}
OPTION 5 EF{E F }
OPTION 6 21 {21}
If the CCU ports have been checked and found to be incorrect or not located then " - - " will appear in place of "O.K.".
Service Aids
To aid in the service of our current chassis there are a number of Service Aids which have been made available.
• LUCI interface kit (Linked Utility Computer Interface)
Part number: TZS6EZ002
This contains interface and cables for connecting TV service connector and a PC as well as diagnostic software. As new
models are introduced upgrade software will become available.
• VICI (Visual Interactive Computer Information)
These C.D.'s contain multimedia documentation providing quick access to service information.
Part No. TZS7EZ006, TZS7EZ005 & TZS8EZ001
1. Service Manuals
2. Instruction Books
3. Technical Information
• TASMIN (Technically Advanced System for Multimedia Interactive Notes)
As well as providing a first step towards more interactive training this product also achieves quick access to Technical
Information.
4
ALIGNMENT SETTINGS
(The figures below are nominal and used for representative purposes only.)
Alignment Function Settings / Special features
Horizontal Position
Vertical Position
Horizontal Amplitude
Vert. Amplitude
EW-amplitude
EW-amplitude
Trapezium-comp
Trapezium-comp
H-Pos
061
V-Pos
005
H-Amp
055
V-Amp
054
E/W-Amp1
-128
E/W-Amp2
006
Trapez-1
047
Trapez-2
-128
Optimum setting.
Optimum setting.
Optimum setting.
Optimum setting.
Optimum setting.
Optimum setting.
Optimum setting.
Optimum setting.
Vertical Linearity
Vertical Symmetry
DVCO
Cut-off DC
Ug2 Test
Highlight
Lowlight
Sub-Brightness
V-Lin
006
V-Sym
002
DVCO
-005
Cut-off
0171
Ug2
055
O.K.
High 0902 0777 0864
Low 0117 0132 0112
Sub-Brightness
255
Optimum setting.
Optimum setting.
Receive a PAL Colour Bar Pattern. For
DVCO alignment press "Blue" button, wait
until the colours are changing slowly and
press "STR".
To adjust Cutoff connect an oscilloscope to
the blue cathode, adjust "cutoff" value
using the "Yellow" and "Blue" buttons until
the black level is 160V±5V press "STR" to
store the value. Remove the oscilloscope.
Select Ug2 adjustment and adjust the
screen VR until the display shows "O.K."
Black Level
160V±5V
GND
Optimum setting.
Optimum setting.
6