Panasonic NV-SD260B Service Manual

TechInfo Sheet fax: 01344 853689
Audio Visual email: av.technical@mail.panasonic.co.uk
Product Group: VCR Model: NV-SD260B Date: 05/11/98 Revision No: 01 Document No: 01 Subject: Common Faults
CHANNEL LOCK UP PROBLEM
SYMPTOM: The position on the Front Information Panel (FIP) can be changed or locked
but the tuner picture is always the same when the customer changes the channel on the VCR. Also, there is no OSD.
CAUSE: The channel data transmission between IC7706 and IC7704 (serial clock
& serial data) is corrupted (permanently keeping the signal HIGH), but data transmission of the OSD microprocessor and system microprocessor are correct (for FIP display). Therefore, the result being that the FIP display works properly but the tuner data does not, resulting in an error.
REMEDY: Please add the oscillation circuit to prevent the noise effect on IC7708.
Reference No. Add the Parts Delete the Parts
X7701 VSX0875 ---------­C7740 ECUM1H150JCN ---------­C7741 ECUM1H150JCN ---------­R7798 ERJ6GMYJ102 ---------­C7733 ---------- ECUN1H103ZFN
Please refer to the details of the new circuit layout on the next page.
PARTS KIT NUMBER
VSX0875KIT
Panasonic CS U.K. Document No: 01
Model: NV-SD260B
1
TechInfo Sheet fax: 01344 853689
Audio Visual email: av.technical@mail.panasonic.co.uk
CHANGE OF CYLINDER UNIT
SYMPTOM: Different cylinder unit fitted, this unit may be identified by the letter “U” on
serial number label as shown below.
NEW PARTS: DESCRIPTION OLD PART NO. NEW PART NO.
Cylinder Unit VEG1198 VEG1360 Upper Cylinder VEH0707 VEH0832 Stator Unit - VEK7236 Rotor Unit - VXP1500 Cylinder Retainer - VDB1256
A supplement service manual may be ordered using part number .NV-SD200B/SUPP