Panasonic LS-H92 User Manual

Easy setting, dual display
Maximum display of 9999
2 switches enabling simple operation
Connects easily sensor head and output wire by one-touch connector
LS-400SERIES
High power even eliminates dust effects
The sensors are high-powered, so that they can be used even in extremely dusty environments.
LS-H92(F
)
DIGITAL LASER SENSOR
Assorted mounting brackets available
Because their mounting is compatible with general purpose photoelectric sensors, the mounting brackets for the general purpose photoelectric sensors as well as the universal sensor mounting stand can be used.
Sensing position can be checked
Bright visible light spots and a digital display amplifier allow beam axis alignment to be carried out easily even when using long-range sensing.
Sensing of projections from conveyor belts
Sensing items inside large stockers
APPLICATIONS
LS-H92
Previous model
30 m
98.425 ft
7 m
22.966 ft
Long sensing range coaxial retroreflective type
A spot diameter of approx. "3 mm "0.118 in at a 3 m 9.843 ft sensing range
Ultra long-range sensing up to 30 m 98.425 ft is possible!
Approx. 4.3
times longer
Approx. 4.3
times longer
Conforming to EMC Directive
Industry standard mounting pitch
The mounting pitch of sensor heads is 25.4 mm 1.000 in, the same
industry standard as the CX-400 series general purpose photoelectric sensors. The mounting brackets can be used as is even when replacing general purpose sensors with laser sensors.
FDA approved types are also available
25.4 mm
1.000 in
PHOTOELECTRIC SENSOR
(LS-H only)
GB
(LS-H92F only)
FDA
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Phone: +81-(0)568-33-7211 FAX: +81-(0)568-33-2631
SUNX Limited
Phone: +81-(0)568-33-7861 FAX: +81-(0)568-33-8591
Overseas Sales Dept.
http://www.sunx.co.jp/
All information is subject to change without prior notice.
No.PCE-LSH92 May, 2005
Cautions for laser beams
IEC / JIS / GB standards conforming type
Never use this product as a sensing device for personnel protection.
In case of using sensing devices for personnel protection, use products which meet standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.
The safety standard IEC 60825-1-2001 specifies the use of laser
beam products. Please read it carefully before using the laser beam sensor.
PRECAUTIONS FOR PROPER USE
PRECAUTIONS FOR PROPER USE
Type
Model No.
Item
Applicable amplifiers
U-LG
STD
FAST
H-SP
Operation indicator
Laser emission indicator
Ambient temperature
Material
Cable
Weight
Emitting element
Accessories (Note 5)
IEC / JIS / GB standards conforming type
LS-H92
FDA / IEC / JIS standards conforming type (Note 2)
LS-H92F
LS-401(P), LS-401(P)-C2
0.2 to 30 m 0.656 to 98.425 ft (Note 3)
0.2 to 20 m 0.656 to 65.617 ft (Note 3)
0.2 to 10 m 0.656 to 32.808 ft (Note 3)
0.2 to 10 m 0.656 to 32.808 ft (Note 3)
Orange LED (lights up when the amplifier output is ON)
Green LED (lights up during laser emission)
10 to 55 C 14 to 131 F (No dew condensation or icing allowed)
Sensing range
RF-230 (Reflector): 1 pc. Warning label: 2 pcs. (English 1 pc. and Japanese 1 pc.)
RF-230 (Reflector): 1 pc. Warning label: 2 pcs. (English 1 pc. and Japanese 1 pc.)
Notes: 1)
2)
3)
4)
5)
Measurement conditions that are not specified are at an ambient temperature of
23 C 73.4 F.
FDA approved devices based on Laser Notice No. 50. The sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.2 m 0.656 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. Cable cannot be extended. LS-H92(F) are also available without the reflector. IEC / JIS / GB standards conforming type: LS-H92-Y FDA / IEC / JIS standards conforming type: LS-H92F-Y
Enclosure: PBT (Polybutylene terephthalate)(Mounting part: PEI), Lens cover: Acrylic
0.1 mm2, single core two parallel shielded cables, 2 m 6.562 ft long (Note 4)
Net weight: 30 g approx., Gross weight: 40 g approx.
This catalog is a guide to select a suitable product. Be sure to read the instruction manual attached to the product prior to its use.
DIMENSIONS (Unit: mm in)
The CAD data in the dimensions can be downloaded
from the SUNX website: http://www.sunx.co.jp/
LS-H92 LS-H92F
Sensor head
Red semiconductor laser, Class 2 (IEC / JIS / GB)
Max. output: 3 mW or less
,
peak emission wavelength: 655 nm 0.026 mil
Red semiconductor laser, Class 2 (FDA / IEC / JIS)
Max. output: 3 mW or less, peak emission wavelength: 655 nm 0.026 mil
When placing the sensor head horizontally or vertically, the reflector shall also be positioned horizontally or vertically.
Fig. 1 Proper positioning
When placing the sensor head horizontally or vertically, but the reflector is leaned.
Fig. 2 Improper positioning
Mounting
RF-230
Reflector (Accessory)
Material: Acrylic (Reflector)
ABS (Base)
2-"4.6 "0.181 mounting holes
50.3
1.980
49.3
1.941
59.3
2.335
30
1.181
40
1.575
5 0.197
8.3
0.327
3.3
0.130
10
0.394
CN-EP1
16
0.630
8.8
0.346
11.2
0.441
5
0.197
1
0.039
7.6
0.299
Laser emission indicator (Green)
Operation indicator (Orange)
"1.45 "0.057, single core two parallel shielded cables
2-M30.5 0.020 thru-hole threads
3 0.118
Beam emitting / receiving part
SPECIFICATIONS
Refer to the LS series catalog or the SUNX website
(http://www.sunx.co.jp/) for details on amplifiers.
These products are class 2 laser in compliance with FDA / IEC / JIS / GB standards. To reduce the risk of danger, do not look directly at the laser beam or view it through an optical system. The right appears on labels adhered to the product. Handle this sensor as per the instruction on the labels. [In addition, both English and Japanese warning labels are included. (IEC / JIS / GB conforming type)] The English warning label based on FDA standards is pasted on the FDA / IEC / JIS standards conforming type. [In addition, English warning label (based on IEC) is included.]
When placing the sensor head horizontally or vertically, the reflector must also be positioned horizontally or vertically as shown in Fig. 1 below. If the sensor head is placed horizontally or vertically but the reflector is leaned as shown in Fig. 2 below, the reflection amount will decrease, which may cause unstable detection.
Good
Not good
15.5
0.610
31
1.220
25.4
1.000
25
0.984
18
0.709
2,000
78.740
( )
( )