٨
The following labels are affixed on this product in accordance with the
FDA and IEC 60825-1 standard.
INSTRUCTION MANUAL
Photoelectric Sensor
LS-HغF Series
Thank you very much for using SUNX products. Please read this Instruction
Manual carefully and thoroughly for the correct and optimum use of this product.
Kindly keep this manual in a convenient place for quick reference.
٨
Never use this product as a sensing device for personel protection.
٨
In case of using sensing devices for personnel protection, use
products which meet standards, such as OSHA, ANSI or IEC etc.,
for personnel protection applicable in each region or country.
٨
Do not view direct beam by the unprotected eye or with
WARNING
1
FOR SAFE USE OF A LASER PRODUCT
٨
With regard to safety of laser products, IEC 60825-1 'Safety of laser products'
has been stipulated by the IEC (International Electrotechnical Commission). In
IEC 60825-1, laser products are divded into classes corresponding to the degree of danger of the laser component, and preventive measures to assure
safety which should be taken with each class are stipulated.
This product is classified as a 'Class 2 laser product' by IEC 60825-1.
٨
This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice
No. 50, dated July 26, 2001, issued by CDRH (Center for Devices and
Radiological Health) under the FDA (Food and Drug Administration). For
details, refer to the Laser Notice No. 50.
٨ Classification of laser product
Classification
Class 1
Class 1M
Class 2 Low power; eye protection normally afforded by aversion responses.
Class 2M As for class 2 except may be more hazardous if user employs optics.
Class 3R Direct intrabeam viewing may be hazardous.
Class 3B Direct intrabeam viewing normally hazardous.
Class 4 High power; diffuse reflections may be hazardous.
٨
Summary of user precautions of a laser product (IEC60825-1)
Laser safety
officer
Remote interlock
Key control
Beam attenuator
Emission indicator
Warning signs
Beam path
Specular reflection
Eye protection
Protective clothing
Training
Notes 1):
2):
an optical instrument. Lasers are potentially hazardous.
٨
Use of control or adjustment or performance of procedures other than those specified in this instruction
manual may result in hazardous rediation expose.
Safe under reasonably foreseeable conditions.
As for Class 1 except may be hazardous if user employs optics.
11M22M 43R 3BClass
Not required but recommended for applications that involve direct viewing of the laser
beam
Not required
Not
required
No requirements
No requirements
This table is intended to provide a convenient summary of precautions. See
text of IEC standard for complete precautions.
The user precautions depend on the wavelength, the aperture stop and the
distance etc. See text of IEC standard for complete precautions.
(Note 2) (Note 2)
(Note 2)
No requirements
No requirements
(Note 2)
Laser Sensor Head
Conforming to FDA
(IEC60825-1)
Description of hazard class
Not required
Not required
Not required
Not required
Not
required
No requirements
No requirements
(Note 2)
(Note 2)
Not required
for visible
emission
Required
non-visible
emission
Indicates laser
is energized
for non-visible
wavelength
Terminate beam at end of useful
Prevent unintentional reflections
Required for all operator and
maintenance personnel
Required
Connect to room or door circuits
Remove key when not in use
When in use prevents inadvertent
Indicates laser is
energized
Follow precautions on warning signs
Reqiuired if engineering and
administrative procedures not
practicable and MPE exceeded
Sometinmes
required
Sometinmes
required
LASER RADIATION
DO NOT STARE INTO BEAM
Maximum output : 3mW
Pulse duration : 3㱘s
Medium : Semiconductor Laser
Wave length : 655nm
FDA
CLASS 2 LASER PRODUCT
(Label based on IEC 60825-1(Label based on
IEC60825-1 2001
<Label position>
DO NOT STARE INTO BEAM
Maximum output : 3mW
Pulse duration : 3㱘s
Medium : Semiconductor Laser
CLASS 2 LASER PRODUCT
Wave length : 655nm
IEC60825-1 2001
LASER RADIATION
Direction of
laser emission
Direction of
laser emission
٨
Laser emission indicator (green)
While laser is emitted, the laser emission indicator (green) of the sensor head lights up.
This indicator is visible even when wearing laser protective glasses.
Direction of
laser emission
2
SPECIFICATIONS
Type
Coaxial retroreflective
Item
Sensing
range
(Note)
Ambient temperature
Emitting element
Accessories
Model No.
0.1 to 3m 30 to 300mmH-SP mode
0.1 to 3m 30 to 300mmFAST mode
0.1 to 5m 30 to 500mmSTD mode
0.1 to 7m 30 to 1,000mmU-LG mode
Orange LED (Lights up when amplifier output is ON)Operation indicator
-10 to 55(No dew condensation or icing allowed), Storage: -20 to 70
Connector for amplifier:
1 pc.
RF-330 (Reflector): 1 pc.
Warning label (IEC) : 1 pc.
Green LED (Lights up when laser is emitted)Laser emission indicator
Red semiconductor laser Class 2 (FDA/IEC standard)
(Max. output: 3mW or less, Peak emission wavelength: 655nm)
Enclosure: PBT(Attachment: PEI), Lens cover: AcrylicMaterial
Note: Configure the mode settings in the applicable amplifier LS-400 series.
3
CAUTIONS
Operation indicator (Orange)
Laser emission indicator (Green)
LS-H21FLS-H91F
LS-400 seriesApplicable amplifier
2
shielded cable, 2m longCable
30g approx.Weight
Diffuse reflective type
Long sensing range spot reflective
35㨪85%RH, Storage: 35㨪85%RHAmbient humidity
0.1mm
Connector for amplifier:
1 pc.
Warning label (IEC): 1
Long
sensing range
LS-H22F
30 to 300mm
30 to 300mm
30 to 500mm
30 to 1,000mm
Connector for amplifier:
1 pc.
LS-MR1 (Lens attachment
for line reflection): 1 pc.
pc.
Warning label (IEC): 1
line reflective
pc.
This product has been designed to meet the specifications when it is used
along with the optional exclusive amplifier. If an amplifier other than the
exclusive amplifier is used, not only the specifications may not be met, but
it may also be a cause for malfunction or break down. Hence, please
ensure to use this product along with the optional exclusive amplifier.
٨
Always use the sensor with the connector to be joined to the amplifier.
٨
Make sure that the power is off while wiring to the amplifier.
٨
In case noise generating equipment (switching regulator, inverter motor
etc.) is used in the vicinity of this product, connect the frame ground
(F.G.) terminal of the equipment to an actual ground.
٨
If power is supplied from a commercial switching regulator, ensure that the frame
ground (F.G.) terminal of the power supply is connected to an actual ground.
٨
Do not use the sensor during the initial transient time (0.5 sec.) just after
the power supply is switched on.
٨
Do not run the wires together with high-voltage lines or power lines or put
them in the same raceway. This can cause malfunction due to induction.
٨
Take care that the sensor head is not directly exposed to fluorescent
lamp from a rapid-starter lamp or a high frequency lighting device, as it
may affect the sensing performance.
٨
The sensor head cable cannot be extended.
٨
Make sure that stress is not applied directly to the sensor head cable joint.
٨
This sensor is suitable for indoor use only.
٨
Do not allow any water, oil fingerprints, etc., which may refract light, or dust, dirt,
etc., which may block light, to stick to the emitting/receiving surfaces of the sensor
head. In case they are present, wipe them with a clean, soft cloth or lens paper.
٨
Do not use the sensor in vaporous, dusty or corrosive gas atmospheres.
٨
Take care that the sensor does not come in direct contact with water, oil,
grease or organic solvents, such as, thinner, etc.
٨
Make sure that the power is off while cleaning the emitting/receiving
windows of the sensor head.
4
MOUNTING
٨
The tightening torque should be 0.5N㨯m or less.
M3 (length 12 mm)
screw with washers
Sensor bracket
(optional)
٨
When placing the sensor horizontally or vertically, the reflector must also
be positioned horizontally or vertically as shown in Fig. 1 below.
If the sensor is placed horizontally or vertically but the mirror is tilted as
shown in Fig. 2 below, the reflection amount will decrease, which may
cause unstable detection.
<Fig. 1 Proper positioning>
When placing the sensor horizontally or vertically, the reflector shall also
be positioned horizontally or vertically.
Removing method
Ԙ
Insert a screwdriver into the fixing
Fixing slot
slot located at the top of sensor.
ԙ
Tilt the screwdriver inserted in Step
to removeLS-MR1.
Ԙ
Mounting method
Ԙ
The size of upper fixing hook of LS-MR1
Lens attachment for line
reflective type
LS-MR1
Fixing hooks
is not same as lower fixing hook.
After confirming upper and lower fixing hooks, insert LS-MR1 upper fixing
hook into the fixing slot at the top of sensor and then insert LS-MR1
lower fixing hook into the fixing slot at the bottom of sensor.
ԙ
After mounting, check that LS-MR1 is properly fixed to the sensor.
9
WIRE CONNECTION
٨
The cable of sensor head can be shortened to your desired length.
However, it cannot be extended.
Releasing procedure
Ԙ Use a flat-head screwdriver (Blade width: 2mm or less) to
push the operating lever (white) located at the wire inlet
and remove the wire.
<Fig. 2 Improper positioning>
When placing the reflector tilted even when the sensor is positioned
horizontally or vertically.
5
BEAM ALIGNMENT (Only for LS-H91F)
Ԙ
Placing the sensor and the reflector face
Sensing object
to face along a straight line, move the
reflector in the up, down, left and right
directions. In order to determine the
range of the beam received condition with
the help of the operation indicator. Then,
set the sensor at the center of this range.
ԙ
Simillarly, adjust for up, down, left
and right angular movement.
Ԛ
Furthermore, perform the angular
Sensor
Reflector
adjustment for the sensor also.
6
CONNECTOR PIN POSITION
Terminal No.
Ԙ
Conductive core: Brown
ԙ
Shielded wire
Ԛ
Conductive core: Yellow
ԛ
Shielded wire
7
SPOT-SIZE ADJUSTER (Only for LS-H21F and LS-H22F)
Connecting cable
Cable color: Gray
Cable color: Black
٨ The diffuse reflective type LS-H21F and LS-H22F incorporates the spot-
size adjuster to adjust the size of spot diameter.
DescriptionSpot-size adjuster
Turn the spot-size adjuster clockwise or counterclockwise to
adjust the spot diameter at your desired detecting distance.
However, if the adjuster is over turned, it may be damaged.
Wire connecting procedure
Ԙ
Process the core length to 7 to 8 mm in accordance with 'STRIP GAUGE'
indicated on the side of this unit, and twist the core several times.
When using shielded wires,
twist the wire until obtaining
the
diameter of Ǿ1.2 mm or less.
ԙ
Use a flathead screwdriver (Blade width:
2 mm or less) to push the operating
Connector
for amplifier
STRIP GAUGE
Core length:
7 to 8 mm
Flathead screwdriver
(Blade width: 2 mm or less)
lever (white) located at the operating
area until it is locked.
Operating
Ԛ
Insert the wire to the innermost of
the wire inlet.
Check that the shielded wire is
area
Wire
connection
area
Shielded wire
Wire inlet
properly inserted into the wire inlet
as well as that the core end has
passed through the wire connection area as shown in the right figure.
ԛ
Place the head of a flathead screwdriver underneath the operating
lever (white) through the releasing
slot, and lift the screwdriver head.
If you hear a snap, the operating
lever (white) is returned and the
wire is fixed.
Operating lever
(white)
Releasing slot
Ԝ Slightly pull the wire to ensure that
wire is not loose. When using
shielded wires, also check that
they do not contact each other.
Shielded wires
Wire
8
LENS ATTACHMENT FOR LINE REFLECTIVE TYPE (LS-MR1)
٨
The lens attachment for line reflective type LS-MR1 mounted in the long
sensing range line reflective type LS-H22F is removable.
When LS-H22F is used without LS-MR1, it will provide the equivalent
performance to the long sensing range spot reflective type LS-H21F. In
addition, the optional LS-MR1 can be attached to LS-H21F to obtain the
performance equivalent to LS-H22F.
٨
Keep the lens from dust, dirt, water, oil, grease, etc.
٨
Do not apply any excessive force to LS-MR1. Such force may cause damage.