Panasonic LS-H, LS-H91, LS-H92, LS-H21, LS-H22 Instruction Manual

INSTRUCTION MANUAL
Laser Sensor Head
LS-H Series
Thank you very much for purchasing Panasonic products. Read this Instruction Manual carefully and thoroughly for the correct and optimum use of this product. Kindly keep this manual in a convenient place for quick reference.
Never use this product as a sensing device for personnel protection.
In case of using sensing devices for personnel protection, use
products which meet standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. Do not view direct beam by the unprotected eye or with an
WARNING
optical instrument. Lasers are potentially hazardous. Use of control or adjustment or performance of procedures
other than those specified in this instruction manual may result in hazardous radiation expose.
1
FOR SAFE USE OF A LASER PRODUCT
In order to prevent the accident by laser product and protect the users,
JIS C 6802
-2014 “Safety of laser products” was established based on the
regulation of IEC (International electrotechnical Commission). This regulation classifies laser products according to the level of hazard, and provides the safety measures for respective classes.
This product are classified as “Class 2 laser products” according to IEC 60825-1-2014 (JIS C 6802-2014) “Safety of laser products”.
Laser hazardous class
Classification according to IEC 60825-1
Visible beam, low power. Blink response of eye affords protection.Class 2
The following label is affixed on this product in accordance with the
Description of hazardous evaluationClass
-2014 (JIS C 6802-2014)
Safety of laser product.
Warning label
In Japanese
クラス1レーザ製品
JIS C 6802
(Based on JIS C 6802-2014)
In English
<Label position>
Direction of laser emission
JIS C 6802
クラス1レーザ製品
When this product is used in China,
In Chinese
affix the chinese warning label (accessory) on the label in the product.
If the affixed label on this product may not be visible after installation of
the product, affix the accessory lable close to the product where you can see.
In Japanese
In English In Chinese
MJE-LSH No.0059-56V
(Based on IEC 60825-1-2014)
Direction of laser emission
(Based on GB 7247.1
-2012
)
2
SPECIFICATIONS
Coaxial retroreflective type (Note 2)
Type
Model No. (Note 1)
Item LS-H21LS-H91
Sensing range (Note 4)
Ambient temperature Ambient humidity
Emitting element
Accessories
Notes: 1)
The model No. with suffix '-C5' stands for the 5m cable length type. (e.g.) LS-H91-C5
2)
The model No. of retroreflective type sensor with the suffix '-Y' is the sensor without the RF-330 and RF-230 reflector. Arrange the reflector separately. (e.g.) LS-H91-Y
3)
LS-H22 is the model No. for the long sensing range spot reflective type (LS-H21) with the lens attachment for line reflective type (LS-MR1). 'LS-H21' is indicated on the actual product.
4)
Configure the mode settings in the applicable amplifier LS-400 series.
3
CAUTIONS
0.1 to 3m 30 to 300mm 30 to 300mmH-SP mode
0.1 to 3m 30 to 300mm 30 to 300mmFAST mode
0.1 to 5m 30 to 500mm 30 to 500mmSTD mode
0.1 to 7m 30 to 1,000mm 30 to 1,000mmU-LG mode
-10 to +55 (No dew condensation or icing allowed), Storage: -20 to +70
Red semiconductor laser Class 2 (IEC/JIS/GB/KS standard) (Max. output: 3mW or less, Peak emission wavelength: 655nm)
Connector for amplifier: 1 pc. RF-330 (Reflector) : 1 pc. Warning label
Japanese / English / Chinese
: 1 set
Long sensing range
LS-H92
LS-400 seriesApplicable amplifier
0.2 to 10m
0.2 to 10m
0.2 to 20m
Orange LED (Lights up when amplifier output is ON)Operation indicator
Enclosure: PBT (Attachment: PEI), Lens cover: AcrylicMaterial
0.2 to 30m
Green LED (Lights up when laser is emitted)Laser emission indicator
3585% RH, Storage: 3585% RH
2
shielded cable, 2m longCable
0.1mm 30g approx.Weight
Connector for amplifier: 1 pc. RF-230 (Reflector) : 1 pc. Warning label
Japanese / English / Chinese
: 1 set
Diffuse reflective type
Long sensing range spot reflective
Connector for amplifier: 1 pc. Warning label
Japanese / English / Chinese
: 1 set
Long sensing range line reflective
LS-H22 (Note 3)
Connector for amplifier: 1 pc. LS-MR1 (Lens attachment for line reflective type): 1 pc. Warning label
Japanese / English / Chinese
: 1 set
This product has been designed to meet the specifications when it is used along with the optional exclusive amplifier. If an amplifier other than the exclusive amplifier is used, not only the specifications may not be met, but it may also be a cause for malfunction or break down. Hence, please ensure to use this product along with the optional exclusive amplifier.
Always use the sensor with the connector to be joined to the amplifier.
Make sure that the power is off while wiring to the amplifier.
In case noise generating equipment (switching regulator, inverter motor
etc.) is used in the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground. If power is supplied from a commercial switching regulator, ensure that
the frame ground (F.G.) terminal of the power supply is connected to an actual ground. Do not use the sensor during the initial transient time (0.5 sec.) just after
the power supply is switched on. Do not run the wires together with high-voltage lines or power lines or put
them in the same raceway. This can cause malfunction due to induction. Take care that the sensor head is not directly exposed to fluorescent
lamp from a rapid-starter lamp or a high frequency lighting device, as it may affect the sensing performance. The sensor head cable cannot be extended.
Make sure that stress is not applied to the sensor head cable joint.
This sensor is suitable for indoor use only.
Do not allow any water, oil fingerprints, etc., which may refract light, or
dust, dirt, etc., which may block light, to stick to the emitting/receiving surfaces of the sensor head. In case they are present, wipe them with a clean, soft cloth or lens paper. Do not use the sensor in vaporous, dusty or corrosive gas atmospheres.
Take care that the sensor does not come in contact with water, oil,
grease or organic solvents, such as, thinner, etc. Make sure that the power is off while cleaning the emitting/receiving
windows of the sensor head.
Laser emission indicator (green)
While laser is emitted, the laser emission indicator (green) of the sensor head lights up. This indicator is visible even when wearing laser protective glasses.
Direction of laser emission
Operation indicator (Orange)
Laser emission indicator (Green)
4
MOUNTING
●●The tightening torque should be 0.5N・
m or less.
M3 (length 12 mm) screw with washers
When placing the sensor horizontally or vertically, the reflector must also be positioned horizontally or vertically as
Sensor bracket (optional)
shown in Fig. 1 below. If the sensor is placed horizontally or vertically but the mirror is tilted as shown in Fig. 2 below, the reflection amount will decrease, which may cause unstable detection.
<Fig. 1 Proper positioning>
When placing the sensor horizontally or vertically, the reflector shall also be positioned horizontally or vertically.
Good
<Fig. 2 Improper positioning>
When placing the reflector tilted even when the sensor is positioned horizontally or vertically.
Not good
Note: The diagrams above are examples for the sensor head (LS-H91) with the reflector (RF-330).
For the sensor head (LS-H92) with the reflector (RF-230), take care of the posisioning as well.
5
COAXIAL RETROREFLECTIVE TYPE (Only for LS-H91 and LS-H92)
In principle, the coaxial retroreflective type (LS-H91 and LS-H92) may be
unable to detect a mirror object or an object which easily diffuses the receiving light at a short sensing distance since the polarized light becomes unstable. In this case, take the following measures.
<Measures>
Lower the receiving light sensitivity with the M.G.S. function of the
amplifier. Change the response time.
Make the distance between the sensor head and the sensing object
farther.
The receiving light intensity may change depending on the surface
condition of the reflector. When a threshold value is set with the applicable amplifier LS-400 series, sufficient margin should be taken into accout. LS-H92 is in super high sensitivity setting. Thus, the output may be unstable
since it can be easily affected by extraneous noise. In this case, lower the the receiving light sensitivity with the M.G.S. function. The sensing distance depends on the receiving light sensitivity as shown in the table below.
M.G.S. function
Response time
H-SP, FAST
STD
U-LG 30m 20m 10m 7m
Note: The value above is with the reflector (RF-230).
6
SPOT-SIZE ADJUSTER (Only for LS-H21 and LS-H22)
The diffuse reflective type (LS-H21 and LS-H22) incorporates the
spot-size adjuster to adjust the size of spot diameter.
7
LENS ATTACHMENT FOR LINE REFLECTIVE TYPE (LS-MR1) (Only for LS-H21 and LS-H22)
The lens attachment for line reflective type (LS-MR1) mounted in the
long sensing range line reflective type (LS-H22) is removable. When LS-H22 is used without LS-MR1, it will provide the equivalent performance to the long sensing range spot reflective type (LS-H21). In addition, the optional LS-MR1 can be attached to LS-H21 to obtain the performance equivalent to LS-H22. Keep the lens from dust, dirt, water, oil, grease, etc.
Do not apply any excessive bending force
to LS-MR1. Such force may cause damage.
Removing method
Insert a screwdriver into the fixing
slot located at the top of sensor. Tilt the screwdriver inserted in Step
to remove LS-MR1.
Level 4 Level 3 Level 2 Level 1
- -
Turn the spot-size adjuster clockwise or counterclockwise to adjust the spot diameter at your desired detecting distance. However, if the adjuster is over turned, it may be damaged.
10m 4m 3m 20m 8m 5m
DescriptionSpot-size adjuster
Fixing slot
Lens attachment for line reflective type (LS-MR1)
Fixing slot
Fixing hooks
Mounting method
The size of upper fixing hook of LS-MR1 is not same as lower fixing
hook. After confirming upper and lower fixing hooks, insert LS-MR1 upper fixing hook into the fixing slot at the top of sensor and then insert LS-MR1 lower fixing hook into the fixing slot at the bottom of sensor. After mounting, check that LS-MR1 is properly fixed to the sensor.
8
WIRE CONNECTION
The cable of sensor head can be shortened to your desired length.
However, it cannot be extended.
<Connector for amplifier connection>
Wire inlet
1234
Operating lever (white)
Strip gauge
STRIP GAUGE
Wire inlet
Operating lever (white)
Releasing slot
Releasing procedure
Use a flat-head screwdriver (Blade width: 2mm or less) to
push the operating lever (white) located at the wire inlet and remove the wire.
Blade width 2mm or less
Wire connecting procedure
Process the core length to 7 to 8 mm in accordance with 'STRIP
GAUGE' indicated on the side of this unit, and twist the core several times. When using shielded wires, twist the wire until obtaining the diameter of φ1.2 mm or less.
Use a flathead screwdriver (Blade
width: 2 mm or less) to push the operating lever (white) located at
Connector for amplifier
STRIP GAUGE
Core length: 7 to 8 mm
Wire
Flathead screwdriver
Blade width: 2mm or less
the operating area until it is locked.
Insert the wire to the innermost of
the wire inlet. Check that the shielded wire is
Operating area
Wire connection area
Shielded wire
Wire inlet
properly inserted into the wire inlet as well as that the core end has passed through the wire connection area as shown in the right figure.
Terminal No.
① ② ③ ④
Place the head of a flathead
Connecting cable Conductive core: Brown Shielded wire Conductive core: Yellow Shielded wire
Cable color: Gray
Cable color: Black
Core end
screw-driver underneath the operating lever (white) through the releasing slot, and lift the screw­driver head.
Operating lever (white)
Releasing slot
If you hear a snap, the operating lever (white) is returned and the wire is fixed.
Lightly pull the wire to ensure that
Shielded wires
wire is not loose. When using shielded wires, also check that they do not contact each other.
9
INTENDED PRODUCTS FOR CE MARKING
The models listed under “ SPECIFICATIONS” come with CE
2
Marking. As for all other models, please contact our office.
http://panasonic.net/id/pidsx/global
Overseas Sales Division (Head Office)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Phone: +81-568-33-7861 FAX: +81-568-33-8591
For sales network, please visit our website.
PRINTED IN JAPAN © Panasonic Industrial Devices SUNX Co., Ltd. 2017
Loading...