Panasonic KXMB1520SL, KXMB1500SL, KXMB1500BL, KXMB1520JT, KXMB1520BL Operating Instructions

...
Important Information Guide
Multi-Function Printer
Model No. KX-MB1500BL
KX-MB1500GX
KX-MB1500FR
KX-MB1520FR
KX-MB1520SP
KX-MB1520G KX-MB1520NL
KX-MB1500G
KX-MB1500SL
KX-MB1520SL
KX-MB1520BL
n Replacement accessory
FOR ENGLISH USERS: You can select English for the display and report (feature #110).
To ensure that the unit operates properly, we recommend the use of Panasonic toner cartridge. – Toner cartridge
R Model No. (Part No.): KX-FAT410X
n The supplied Setup CD-ROM provides the Operating Instructions in PDF format with a detailed description on how to use the unit. Adobe Reader® is required to view them. Please read before using the unit and save the CD-ROM for future reference. R Save the original carton and packing materials
for future shipping and transportation of the unit.
R After unpacking the product, take care of the
packing materials and/or power plug cap appropriately.
R The suffix in the model number will be omitted in
these instructions.
Language selection:
You can select the desired language.
The display and reports will be in the selected language. If you want to change the setting, see the operating instructions (feature #110).
Location selection:
KX-MB1520SP only: R Designed to be used in Spain and Portugal
according to the location setting feature.
The default setting is Spain. To change the location setting, see the operating instructions (feature #114).
®
Caution: R When you operate this product, the power
outlet should be near the product and easily accessible.
R Be sure to use the telephone line cord supplied
with this unit (KX-MB1520 only).
R Do not extend the telephone line cord
(KX-MB1520 only).
R Do NOT connect the unit to a computer with
the USB cable until prompted to do so during the setup of Multi-Function Station (CD-ROM).
Trademarks:
R Adobe and Reader are either registered
trademarks or trademarks of Adobe Systems Incorporated in the United States and/or other countries.
R All other trademarks identified herein are the
property of their respective owners.
Table of Contents
1.1 For your safety 3
1.2 Important safety instructions 4
1.3 Information for Users on Collection and Disposal of Old Equipment and used Batteries
1.4 Illegal copies 4
1.5 Useful Information 5
1.6 Declaration of Conformity (KX-MB1520 only)
4
6
Caution: R The maximum sound pressure level is 70 dB (A)
or less as per EN ISO 7779. (Germany only)
R This device is not intended for use in the direct
field of view at visual display workplaces. To avoid incommoding reflexions at visual display workplaces this device must not be placed in the direct field of view. (Germany only)
R In the event of problems, you should contact your
equipment supplier in the first instance (KX-MB1520 only).
KX-MB1520BL
R This equipment is designed for use on the Belgium
analogue telephone network.
KX-MB1520FR
R This equipment is designed for use on the France
analogue telephone network.
KX-MB1520G
R This equipment is designed for use on the Germany
and Austria analogue telephone network.
KX-MB1520JT
R This equipment is designed for use on the Italy
analogue telephone network.
KX-MB1520NL
R This equipment is designed for use on the
Netherlands analogue telephone network.
KX-MB1520SL
R This equipment is designed for use on the
Switzerland analogue telephone network.
KX-MB1520SP
R This equipment is designed for use on the Spain and
Portugal analogue telephone network.
Declaration of Conformity (KX-MB1520 only):
R Panasonic System Networks Co., Ltd. declares that
this equipment is in compliance with the essential requirements and other relevant provisions of Radio & Telecommunications Terminal Equipment (R&TTE) Directive 1999/5/EC. Declarations of Conformity for the relevant Panasonic products described in this manual are available for download by visiting: http://www.doc.panasonic.de
ENERGY STAR:
R As an ENERGY STAR® Partner, Panasonic has
determined that this product meets the ENERGY STAR guidelines for energy efficiency. ENERGY STAR is a U.S. registered mark.
Contact to Authorised Representative: Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15, 22525 Hamburg, Germany
Information of Compliance with EU relevant Regulatory Directives (KX-MB1500 only):
R Contact to Authorised Representative:
Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15, 22525 Hamburg, Germany
2

1.1 For your safety

To prevent severe injury and loss of life/property, read this section
1. . Important Information
carefully before using the unit to ensure proper and safe operation of your unit.

1.1.1 WARNING

Power and ground connection
R Unplug this unit from power outlets if it emits smoke, an abnormal smell
or makes unusual noise. These conditions can cause fire or electric shock. Confirm that smoke has stopped and contact an authorised service centre.
R Use only the power source marked on the unit. If you are not sure of
the type of power supplied to your home, consult your retailer/dealer or local power company.
R For safety purposes this unit is equipped with a grounded plug. If you
do not have this type of outlet, please have one installed. Do not ignore this safety feature by tampering with the plug.
R Do not place objects on the power cord. Install the unit where no one
can step or trip on the cord.
R Do not overload power outlets and extension cords. This can result in
the risk of fire or electric shock.
R Completely insert the AC adaptor/power plug into the power outlet.
Failure to do so may cause electric shock and/or excessive heat resulting in a fire.
R Regularly remove any dust, etc. from the AC adaptor/power plug by
pulling it from the power outlet, then wiping with a dry cloth. Accumulated dust may cause an insulation defect from moisture, etc. resulting in a fire.
R Never touch the plug with wet hands. There is a danger of electric shock.
Installation
R Place the unit securely on a stable, level surface. Serious damage and/
or injury may result if the unit falls.
R To prevent the risk of fire or electrical shock, do not expose this product
to rain or any type of moisture.
R Use this unit in a well ventilated area. Particularly, if you will be using
the unit for extended periods of time or will be printing in large volumes, be sure to ventilate the room sufficiently.
Operating safeguards
R Turn the power OFF before cleaning. Do not use liquid or aerosol
cleaners.
R Do not cover slots and openings on the unit. They are provided for
ventilation and protection against overheating. Never place the unit near radiators, or in a place where proper ventilation is not provided.
R Never push any objects through slots in this unit. This may result in the
risk of fire or electric shock. Never spill any liquid on the unit.
R To reduce the risk of electric shock, do not disassemble this unit. Take
the unit to an authorised service centre when service is required. Opening or removing covers may expose you to dangerous voltage or other risks. Incorrect reassembly can cause electric shock when the unit is subsequently used.
R Follow all warnings and instructions marked on this unit. R Do not spill liquids (detergents, cleansers, etc.) onto the telephone line
cord plug, or allow it to become wet at all. This may cause a fire. If the telephone line cord plug becomes wet, immediately pull it from the telephone wall jack, and do not use (KX-MB1520 only).
1. Important Information
R Unplug this unit from power outlets and refer servicing to an authorised
service centre when any of the following conditions occur: – If the power cord is damaged or frayed. – If the unit has been exposed to rain or water, or liquid has been
spilled into the unit. Do not use a microwave oven to speed up the drying process of any parts of the unit to avoid permanent damage.
If the unit does not work normally by following the operating
instructions. Adjust only controls covered by the operating instructions. Improper adjustment may require extensive work by
an authorised service centre. – If the unit has been dropped or physically damaged. – If the unit exhibits a distinct change in performance.
USB cable
R To assure continued emission limit compliance, use only shielded USB
cable (Example: Hi-Speed USB 2.0 certified cable).

1.1.2 CAUTION

Installation and relocation
R After moving the unit from cold areas to warmer areas, wait
approximately 30 minutes before turning on the power switch to allow the unit to adjust to the ambient temperature. If the power switch is turned on too soon after a sudden climate change, condensation may form inside the unit, causing malfunction.
R Never turn the unit upside down or sideways when moving it. R Never install telephone wiring during a lightning storm (KX-MB1520
only).
R Never install telephone jacks in wet locations unless the jack is
specifically designed for wet locations (KX-MB1520 only).
R Never touch uninsulated telephone wires or terminals unless the
telephone line has been disconnected at the network interface (KX-MB1520 only).
R Use caution when installing or modifying telephone lines (KX-MB1520
only).
R Do not position the unit in a location where it is unstable or subject to
vibrations.
Laser radiation
CLASS 1 LASER PRODUCT
R The printer of this unit utilises a laser. Use of controls or adjustments
or performance of procedures other than those specified herein may result in hazardous radiation exposure.
See the operating instructions for the Laser diodes properties.
LED light
CLASS 1 LED PRODUCT
R When using the unit, do not look directly at the CIS’s LED light. Direct
eye exposure can cause eye damage.
See the operating instructions where the CIS LED specifications are listed.
Fuser unit
R During or immediately after printing, the fuser unit gets hot. This is
normal. Do not touch the fuser unit.
Detailed operating instructions are on the CD-ROM.