New cycle defrosting
system
Compact and
large capacity
Pharmaceutical
Refrigerators
KM-RS16A1, KM-RS34A1 Series
Temperature range
+2
+2˚C to 14˚C
Compact and
Compact and
large capacity
large capacity
New cycle defrosting
New cycle defrosting
system
system
Medical Refrigerators for reliable
˚C to
14
˚C
KM-RS16A1
storage of pharmaceutical and
medical supplies
• Precise temperature control
• Superior cooling performance
• Forced air circulation
• Double-glazing glass door
• Slim, and space saving design
• Useful alarm functions
KM-RS34A1

KM-RS16A1, KM-RS34A1 Series
Features
Improved Energy Saving
Panasonic’s new cycle defrosting system achieved 15%* energy saving
compared to conventional models. This system observes the defrosting
condition after every cycle, and prevents temperature rises that are
caused by defrosting.
*The data is a measured example (set temp. 5°C, AT 23°C, 230V 50Hz, no load). Actual power
consumption will vary depending on the set and ambient conditions, loading and local voltage.
User Friendly Design
1. New Control Panel
- Newly designed for improved
operability, visibility, and
calibration
- Digital setup for easy and
secure operation
- Temperature alarm settings made on the control panel
2. LED Interior Light
The LED interior light
automatically turns on/off in
conjunction with the door
opening/closing. It can also be
controlled from the control
panel.
3. Double-Paned Glass with Heat-Reflective Film
The refrigerator doors constructed of double-paned glass with heatreflective film, allow easy loading and unloading of medical supplies
while preventing ultraviolet rays, which may damage stored items,
from entering the unit. Panasonic’s unique heat-reflective film blocks
the passage of radiant heat rays through the glass panels and keeps
the inside temperature from being adversely affected by excessive
amounts of heat.
Effective Temperature Control
1. Microprocessor Temperature Control
A thermistor sensor monitors temperature inside the chamber, and
microprocessor temperature control ensures that the set
temperature is maintained. Even if the door is opened and closed
frequently, the circulation fan ensures rapid temperature adjustment
to provide a highly reliable, stable preservation environment that is
not affected by ambient temperature.
2. Fan-Forced Air Circulation
The temperature stays even throughout the inside of the refrigerator
with the fan-forced air circulation system. No matter how the load is
distributed, every corner of the unit is immediately cooled with no
noticeable variation in temperature apparent inside the cabinet.
Enhanced Alarm and Safety Functions
1. Door Open Alarm
When the door is opened, the Door Open indicator lamp lights
automatically. After approx. 2 minutes, a buzzer alarm will sound
if the door has not been closed (settable from 0 to 15 minutes). If
the door remains open even after the buzzer is stopped, the buzzer
rings again after 30 minutes (settable from 0 to 60 minutes in
increments of 10 minutes).
2. Abnormal Temperature Alarm
If the inside temperature changes ±2˚C to ±14˚C from the set
temperature, the digital temperature display flashes, and a buzzer
sounds an alarm after 15 minutes (settable from 0 to 15 minutes).
Specifications
220V-240V, 50Hz
220V, 60Hz
22 0V, 60Hz ( for Saudi Arabia)
22 0V, 60Hz ( for Taiwan)
110/115 V, 60H z
230/240V, 50Hz
220V, 50Hz/60Hz
22 0V, 50Hz /60 Hz (for Saudi Arabia)
22 0V, 50Hz /60 Hz (for Taiwan)
External dimensions (W x D x H)*
Internal dimensions (W x D x H)
Effective capacity
Net weight
External cabinet
Internal cabinet
Insulation
Doors
Shelves
Access port
Lighting / Casters
Compressor
Refrigerant
Evaporator
Condenser
Defrosting
Defrosting heaters
Temperature control
Temperature display
High/Low temperature alarm system
Door ajar alarm
Options
Caution: Panasonic guarantees the product under certain warranty conditions.
Panasonic in no way shall be responsible for any loss of content or damage to content.
• Appearance and specifications are subject to change without notice.
• Water condensation may sometimes appear on the glass doors, but this is normal and not a malfunction.
*1 Exterior dimensions of main cabinet only - see dimension drawings showing handles and other external
projections.
Dimensions
800 (31.5)
720 (28.3) (inside)
1090 (42.9)
405 (15.9)
KM-RS16A1 KM-RS34A1
90 (3.5)
1
Unit : mm (inch)
465 (18.3)
8
(0.3)
450 (17.7)
20 (0.8)
725 (28.5)
300
638 (25.1)
(11.8)
325 (12.8)
KM-RS16A1E
KM-RS16A1K
KM-RS16A1R
KM-RS16A1T
—
—
—
—
800 x 465 x 1090 (mm)
31.5 x 18.3 x 42.9 (inch)
720 x 300 x 725 (mm)
28.3 x 11.8 x 28.5 (inch)
158 liters (5.6 cu.ft.)
71 kg (156 lbs.)
Galvanised steel with baked-on finish
Sliding glass doors, double-glazing glass with
Hermetic type, 90 W
Cyclical defrosting & evaporator temp. detection system
±2˚C to ±14˚C from temperature setting value
MTR-0621LH-PE/PA (recorder fixing: MPR-S30-PW)
MTR-G04C-PE/G04A-PA (recorder fixing: MPR-S7-PW)
Battery mounting box: KM-RPP01BB1W
Interface board: MTR-480-PW, MTR-L03-PW
720 (28.3) (inside)
25
(1.0)
Model No.
—
Stainless steel
Polyurethane foam
heat-reflective film
Hard steel wire
30mm ø on back wall
LED/2 casters
HFC
Fin & Tube, Forced-air circulation
Wire & Tube
87 W
2˚C to 14˚C
Digital (1˚C increments)
Buzzer / door ajar lamp
Temperature recorder:
DAQ system: MTR-5000-PW
800 (31.5)
90 (3.5)
—
—
—
—
KM-RS34A1A
KM-RS34A1E
KM-RS34A1K
KM-RS34A1R
KM-RS34A1T
800 x 465 x 1800 (mm)
31.5 x 18.3 x 70.9 (inch)
720 x 350 x 1435 (mm)
28.3 x 13.8 x 56.5 (inch)
340 liters (12.0 cu.ft.)
100 kg (220 lbs.)
Hermetic type,160 W
101 W
8
465 (18.3)
(0.3)
450 (17.7)
20 (0.8)
300
(11.8)
1435 (56.5)
1800 (70.9)
350
638 (25.1) 638 (25.1)
(13.8)
405 (15.9)
325 (12.8)
25
(1.0)
Panasonic Healthcare Co., Ltd., Medical Systems Business Unit
is certified for:
Quality management system: ISO9001
Medical devices quality management system: ISO134 85
DISTRIBUTED BY:
Panasonic Healthcare Co., Ltd., Medical Systems
Business Unit is certified for:
Environmental management system: ISO14001
http://panasonic.net/healthcare/biomedical/
Printed in Japan 192-2013-09