Panasonic FV-08VS1, FV-05-08VSA1, FV-05VSB1, FV-08VSB1 Supplementary Installation Instructions

READ AND SAVE THESE INSTRUCTIOINS.
Please
read
these
instructions
carefully
before
to
install,
operate or service the Panasonic Ventilating Fan. Failure to comply with instructions could result in personal injury and/or property
damage. Please retain this booklet for future reference.
Applicable to Models: FV-05VS1, FV-08VS1
SUPPLEMENTARY
INSTALLATION INSTRUCTIONS
(For Contractor Pack)
Housing Can
FV-05-08VSA1
Motor/Grille Assembly FV-05VSB1, FV-08VSB1
Table of Contents
2
Unpacking
2
General Safety Information
I
Installation
( Joist Mounting- )I
6-7
4-6
II
Installation
3
Supplied Accessories
3
Wiring diagram
( Joist Mounting- )II
III
Installation
( -Joist Mounting )I
8
IV
Installation
( Between Joist Mounting )
8-9
V
Installation
( Wooden Header )
9
VI
Installation
( In Existing Construction )
10
Product Service
12
VII
VIII
IX
Installation
Installation
Installation
( Wall Installation- )I ( Wall Installation- )II ( Wall Installation- )III
10-11
11
12
GENE AL SAFETY INFO MATIONRRGENE AL SAFETY INFO MATIONRR
1. Do not install this ventilating fan where air temperature may exceed 40 C (104 F).
oo
2. Make sure that the electric service supply voltage is 120V, 60 Hz.
3. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupation Safety and Health Act (OSHA).
4. Always disconnect the power source before working on or near the fan, motor or junction box.
5. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects.
6. Do not kink the power cord.
7. Do not install the unit where ducts are configured as shown in Fig. A.
8. Provide suction parts with proper ventilation.
9. This unit is UL listed for use over a bathtub or shower when installed in a GFCI protected branch circuit.
Fig. A
Prohibition Prohibition Prohibition Prohibition
Adaptor
UNPACKING
Unpack and carefully remove unit from carton. Refer to the Supplied Accessories list to verify that all parts are present.
2
Fig. B
WARNING:
CAUTION:
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. Not for use in cooking area. (Fig .B)
3. This product must be properly grounded.
equipment
Cooking
Floor
Do not install above or
(Cooking area)
inside this area
45
o
45
o
To reduce the risk of fire, electric shock or injury to persons, observe the following: A. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact
to the manufacturer.
B. Installation work and electrical wiring must be done by qualified person(s) in accordance with all
applicable codes and standards, including fire-rated construction.
C. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney)
of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
E. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. F. Ducted fans must always be vented to the outdoors.
G. These models are UL listed for tub and shower enclosures.
H. Solid state controls may cause harmonic distortion which can cause motor humming noise. To reduce
the risk of fire or electric shock, do not use this unit with any solid-state control device.
I. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting
means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
J. NEVER place a switch where it can be reached from a tub or shower.
L. Install the fan at least 1.5m (5 feet) above the floor, and the fan must be installed above a counter or major
appliances that serves as a barrier.
D. The Housing Can FV-05-08VSA1 must be installed with Motor/Grille Assembly FV-05/08VSB1 only.
K. Not to be installed in a ceiling thermally insulated to a value greater than R40. (This is required for
installation in Canada only.)
SUPPLIED ACCESSORIES SETS(4 )SUPPLIED ACCESSORIES SETS(4 )
(A) For Motor / Grille Assembly of model: FV-05/08VSB1
Quantity
Appearance
Part name
Grille
4
(B) For Housing Can of model: FV-05-08VSA1
WIRING DIAGRAM
4
24
4
4
8
4
8
4
Thumb screw
Long screw (ST4.2X20)
Suspension
bracket I
Suspension
bracket II
Screw
(ST4.2X8)
I
Suspension
bracket III
Screw
(ST4.2X10)
II
Quantity
Appearance
Part name
3
Spacer
Fan body
Red
Capacitor
White
Black
Junction box
Black Live
Power supply AC120V 60Hz
White NeutralWhite
Green
Green
Earth
Green
Earth ground Earth ground
OFF
ON
Switch
(not included)
4
INSTALLATION JOIST MOUNTING-II()INSTALLATION JOIST MOUNTING-II()
2 Screw (ST4.2X8)I
Suspension bracket III
Suspension bracket II
2. Insert the supension bracket into the fan body and adaptor. (Select the suspension bracket as shown below)
Spacing a on center joists
Insert suspension bracket
12 inches
16 inches
19.2 inches vertical joists
24 inches
Refer to Fig. 2-1
Refer to Fig. 2-2
Refer to Fig. 2-3
Refer to Fig. 2-4
If spacing A on center joists is 24 inches, connect suspension bracket and (C4 mark to C4 mark) as shown below :
II III
Joists
A
Suspension bracket I
Fig.2-1
Fan body
Suspension bracket I
Suspension bracket III
Fig.2-2
Fan body
Suspension bracket III
Suspension bracket I
Fig.2-3
Fig.2-4
Fan body
Suspension bracket I
Suspension bracket III
Suspension bracket II
Fig.1
Fan body
Remove tape
Adaptor
Damper
1. Before installation, secure the fan body to adaptor by using thumb screw. (Fig.1)
IMPORTANT :
Remove the tape from damper and adaptor before installation. As shown below:
Fan body
Thumb screw
A=12 inches
A=16 inches
A=24 inches
A=19.2 inches (vertical joist)
Loading...