Panasonic fv-05vs3, fv-08vs3, fv-10vs3 installation

FV-05VS3 FV-08VS3 FV-10VS3
2-3
4
4
4
4
5
(Jois t Mou nting)
(Wal l Mou nti ng)
(C le a ni n g)
Back co ver
Back co ver
Back co ver
5-6
6
7
For Your Safety
To reduce the risk of injury, loss of life, electric shock, fire, malfunction, and damage to equipment or property, always observe the following safety precautions.
Explanation of symbol word panels
The following symbol word panels are used to classify and describe the level of hazard, injury, and property damage caused when the denotation is disregarded and improper use is performed.
Denotes a potential hazard that could result in serious
WARNING
injury or death.
CAUTION
The following symbols are used to classify and describe the type of instructions to be observed.
This symbol is used to alert users to a specific operating procedure that must not be performed.
This symbol is used to alert users to a specific operating procedure that must be followed in order to operate the unit safely.
Denotes a hazard that could re sult in m ino r injury.
WARNING
To reduce the risk of fire, electric shock or injury to persons, observe the following :
Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switch on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Ducted fans must always be vented to the outdoors.
If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
These models are UL listed for tub and shower enclosures.
2
WARNING
US A only: Thi s pro duc t has a fluores c ent l am p t hat c ontain s mercury. Dis posal may be regulated in yo ur co mmun it y due to envi ron men tal c onside ration s. Fo r dis posa l or recyc li n g information , p lea se co nta ct yo ur lo cal au tho ri tie s o r visit Pa nas on i c web sit e: ht tp:// www. p ana so nic.com /en vironm ent al or c all 1- 88 8-769- 0149.
Canada only: Not to be installed in a ceiling thermally insulated to a value greater than R40.
A statement to the effect that when the product is to no longer be used, it must not be left in place but removed, to prevent it from possible falling.
Ceiling joist or wall stud must be subjected to static load more than five times the weight of the product.
Do not install with a method which is not approved in the instructions.
Do not use this fan with any solid-state speed control device. Solid state controls may cause harmonic distortion which can cause motor humming noise.
Install the fan at least 1.5m (5 feet) above the floor, and the fan must be installed above a counter or major appliances that serves as a barrier.
This product must be properly grounded.
CAUTION
Do n ot install this ve nti lating fan where interior room t emperature may exceed 104°F (40°C).
Make sure that the electric service sup ply volta ge is AC 12 0V, 60 Hz.
Follow all lo cal electrical and safety codes, as well as the National Electrical Code (NEC) and t he Occupation Safety and Health Act (OSHA).
Alwa ys disco nne ct the po wer source before working on or near the fan, motor, light fixture or junct ion bo x.
Protect the sup ply wiring from sharp ed ges, oil, grease, hot su rfaces, chemicals or other objects.
Do n ot kink t he supply wi ring.
Provide make up air for proper ventilation.
For general ventilating use only. Do not use to exhaust hazard ous or explosive materials and vapors .
Do n ot install the unit where duc ts are configured as sho wn in Fig.A.
Not for use in cooking area. (Fig .B)
Adapt or
The special-purpos e o r dedicated parts, such as mounting fixtures, must be used if such parts are provi ded.
3
Loading...