■ Overview
The DN6852 is an integrated circuit making use of Hall
effects. It is designed particularly for operating at a low supply
voltage in one way magnetic field. It is suitable for various sensors and contactless switches.
■ Features
•
Wide range of supply voltage : 3.6 to 16V
•
Operating in one way magnetic field.
•
TTL and MOS ICs directly drivable by output
•
Semipermanent service life because of no contact parts
•
Drivable with a small magnet
•
3-pin SIL plastic package (3-SIP)
•
Open colector
■ Applications
•
Speed sensors
•
Position sensors
•
Rotation sensors
•
Keyboard switches
•
Microswitches
Note) This IC is not suitable for car electrical equipments.
DN6852
Hall IC
(Operating Supply Voltage Range VCC=3.6 to 16V, Operating in One Way
Magnetic Field)
Unit : mm
SSIP003-P-0000A (E-3S)
1 : V
CC
2 : GND
3 : Output
0.5±0.1
5˚
123
2˚
5˚
5˚
2˚
1.27
4.0±0.3
0.7
4.5±0.3
0.43
+ 0.1
– 0.05
2.0±0.3
0.8±0.1
1.0
10.5±0.5
V
CC
I
CC
I
O
P
D
T
opr
T
stg
Supply voltage
Supply current
Circuit current
Power dissipation
Operating ambient temperature
Storage temperature
V
mA
mA
mW
˚C
˚C
Parameter Symbol Rating Unit
■ Absolute Maximum Ratings (Ta=25˚C)
18
8
20
100
–40 to + 85
–55 to + 125
Stabilized power supply
1 V
CC
3
Output
2
Hall element Amp. Schmitt trigger Output stage
GND
Parameter Symbol Condition min typ max
■ Electrical Characteristics (Ta=25˚C)
Operating flux density
B
1 (L to H)
mT
V
CC
=12V
B
2 (H to L)
mT
V
CC
=12V
Low output voltage V
OL
0.4 V
V
CC
=16V, IO=12mA,
B=60mT
V
V
CC
=3.6V, IO=12mA,
B=60mT
Note1) Operating supply voltage range VCC (opr)=3.6 to 16V
Note2) For the operating flux density, B
2 (H to L)
max 450 mT is also available as Rank A.
mA
V
CC
=16V
I
CC
mA
Supply current
V
CC
=3.6V
6
5.5
0.4
60
10
µA
V
CC
=16V, VO=18V,
B=10mT
10
µA
V
CC
=3.6V, VO=18V,
B=10mT
10
I
OH
High output current
Unit
1.3
1.0
1.75
1.0
Unit : mm
The center of the Hall element is in the hatched area in the left figure.
Marking surface
1 : V
CC
2 : GND
3 : Output
Applied flux direction
N
S
1 2 3
Flux density (B)
Output voltage (V
O
)
B
1
B
2
■ Flux-Voltage Conversion Characteristics
■ Precaution on Use
1. Change of the operation magnetic flux density dose not depend on the supply voltage,
because the stabilization power supply is built-in.
(only for the range ; VCC=4.5 to 16V)
2. Change from “H” to “L” level increases the supply current by approx. 1mA.