Please read these operating instructions thoroughly before using
your air conditioner and keep them for future reference.
For assistance, please call: 1-800-211-PANA (7262) or send e-mail to
consumerproducts@panasonic.com
or refer to
www.panasonic.com
F563447
1
SAFETY PRECAUTIONS
Please observe these following safety precautions when using
your air conditioner.
• Failure or negligence in observing these safety precautions
could cause fire, electrical shock or personal injury.
This symbol (with a white background)
denotes an action that is PROHIBITED.
These symbols (with a blue background) denote
actions that are COMPULSORY.
INSTALLATION PRECAUTIONS
• Due to the weight of this product, we recommend that
you have a helper to assist in the installation. To avoid
injury, use the proper method of lifting. Avoid any sharp
edges.
• Make sure the window frame to be used can
properly support this product.
• This product must be installed in accordance with all local
codes and ordinances.
• Do not install the unit in places where inflammable gas,
fumes or soot may be generated.
OPERATION PRECAUTIONS
• Operate your air conditioner from a stable 115 volt AC
supply.
• Plug into a separate 15 amp grounded outlet only.
• Use of extension cords
Avoid using extension cords. If there are no alternatives,
ensure that the cord is a UL listed 3-wire grounding type,
rated 125 volts with a minimum current-carrying rating of
15 amps, number 14 or heavier wire.
• Use a 15 amp time delay fuse or a circuit breaker .
• Do not switch off by unplugging the power plug while it is
operating. Press the OFF/ON pad to “OFF” before
unplugging.
OPERATION PRECAUTIONS
WARNING
• Do not modify the length of the power cord or use an extension cord.
• Do not touch or operate with wet hands. Do not modify or damage
the cord.
• Do not turn on the unit by inserting the power plug. Do not switch off
the unit by pulling out the power plug.
• Avoid an extended period of direct airflow.
• Do not insert sticks, fingers or other objects into the unit.
• Do not try to repair the unit yourself.
• Plug in properly before operating and use a specified power cord.
• If abnormal conditions (burnt smell, etc) occur, switch off and remove
the power plug.
CAUTION
• Do not use the unit for other purposes, than its intended use.
• Do not remove the power plug by pulling the cord.
• Do not block the air intake and outlet vanes.
• Do not splash or direct water at the unit
• Do not expose the unit to direct sunlight during operation.
• Do not operate the unit without the air filter installed or when the front
intake grille has been removed.
• Do not place any objects on the unit.
• Do not operate any combustion equipment near the unit’s airflow area.
• Switch off the breaker and remove the power plug from the socket if
the unit will not be operated for a long period.
• Pay attention to any damages on the unit caused by extensive usage.
• Ventilate the room occasionally where the unit is installed.
• Remove the power plug when cleaning the unit.
This sign warns of risk of death or serious injury.
This sign warns of injury or damage to property.
POWER SUPPLY
Time Delay Fuse : 15 Amps
Rated Voltage : 115V
• Socket Type
• Line Cord Plug
2
INSTALLATION BOX CONTENTS
Sealer 50 g
(1.8 oz) (Putty)
Type A
screws
Type C screws
Type A screw
Left side
expandable panel
Top sealing
ribbon
Top
angle
Type B screws
ACCESSORIES
AIR CONDITIONER INSTALLATION
NOTE
Check that none of the accessories are missing.
Window sash
foam seal
Type A screws
(6 pcs)
(XTN5D25A)
(5 pcs)
(CWH4580211)
(6 pcs)
(XTT4D10C)
Window sash
sealing ribbon
SCREW FURNISHED
Side
sealing
ribbon
Type A
screw
Type AType BType C
(Qty 6)(Qty 5)(Qty 6)
SUGGESTED TOOL LIST
Type C screws
Right side
expandable
panel
SELECT THE BEST LOCATION
(Single or Double
Window
hung window)
Front grille
SIDE VIEW
WoodMachineTapping
ScrewScrewScrew
Medium sized
screwdriver (#2
Phillips)
Tape Measure
Pencil
Level
Knife or
Scissor
19–3/
inches
16
12 inches
More than
4 inches
WINDOW REQUIREMENTS
O
FF
/O
N
O
P
E
R
A
T
IO
N
TEMP/TIMER
C
O
O
L
F
A
N
H
IG
H
M
E
D
L
O
W
M
O
D
E
F
A
N
S
P
E
E
D
SET
T
IM
E
R
SET/
CANCEL
A
IR
S
W
IN
G
E
C
O
N
O
M
Y
hr
°F
Wireless
R
e
m
o
te
C
o
n
tro
l
O
F
F
/O
N
OPERATION
T
E
M
P
/T
IM
E
R
C
O
O
L
F
A
N
H
IG
H
M
E
D
L
O
W
M
O
D
E
F
A
N
S
P
E
E
D
S
E
T
TIMER
S
E
T
/
C
A
N
C
E
L
A
IR
S
W
IN
G
E
C
O
N
O
M
Y
hr
°F
Wireless
R
em
ote C
ontrol
OFF/ON
O
P
E
R
A
T
IO
N
TEMP/TIMER
COOL
FAN
HIGH
MED
LOW
MODE
FAN SPEED
SET
T
I
M
E
R
S
E
T/
C
A
N
C
E
L
AIR SWING
E
C
O
N
O
M
Y
h
r
°
F
W
ireless
R
em
ote C
on
trol
• Hot sun rays hitting the outside surface
of the cabinet will create considerable
heat load. If the outside of the cabinet is
exposed to direct sunlight, consider
building an awning to shade the cabinet
while providing ample area for the heated
air to be exhausted from the condenser
(both sides) and the top.
(min)
/16”
15
15-
22
to 42-
1
/
8
”
This unit is designed for installation in
standard double hung windows.
NOTE
The unit may also be installed “through the wall”. You should,
however, observe standard carpentry practices and frame the
opening without violating local ordinances.
INSTALLATION PROCEDURES
1 Remove the rear cabinet
screws and save for later use.
2 Slide the chassis out from the
cabinet.
°F
TIMER
O
P
E
R
A
T
IO
T
N
E
M
P
/T
IM
E
R
hr
S
E
T
S
O
E
F
T
/
F
/
O
N
C
A
N
C
E
L
C
O
O
L
F
A
M
N
O
D
E
A
I
R
S
W
I
N
G
H
I
E
G
C
H
O
N
O
M
Y
M
E
D
F
A
N
S
P
E
E
D
L
O
W
Wireless
Remote Control
HOW TO ASSEMBLE THE EXPANDABLE PANELS
Top sealing
ribbon (To be
attached to the
top angle)
Type B screws
NOTE
This procedure applies to left and right
of assembling expandable panel.
Top angle
Expandable panel
Side sealing ribbon
(To be attached to
the expandable
panel)
Type C screws
• Attach the top angle to the cabinet using screw type B (3 pcs).
• Insert expandable panels to cabinet sides as shown.
• Secure the first fold of expansion panel to cabinet using screw
type C (3 each).
CABINET INSTALLATION
CHASSIS INSTALLATION INTO THE CABINET
1 Slide the chassis into the cabinet.
2 Reinstall the cabinet screws.
Secure the cabinet to chassis by using screws (from
rear cabinet).
°F
T
IM
E
O
R
P
E
R
A
T
IO
TEMP/TIMER
N
hr
SET
S
O
E
F
T
/
F
/O
N
C
A
N
C
E
L
C
O
O
L
F
A
M
N
O
D
E
A
IR
S
W
IN
G
H
IG
E
C
H
O
N
O
M
Y
M
E
D
F
A
N
S
P
E
E
D
L
O
W
Wireless
R
e
m
o
te
C
o
n
tro
l
INSTALLATION OF THE FRONT GRILLE
Depending upon the location
of the AC outlet, route the AC
cord to either the left or right
side while installing the front
grille.
This figure shows the AC cord
routed to the left side.
1 Place the front grille on the
cabinet first.
2 Secure the front grille to the
main chassis using screw
provided.
°F
T
IM
E
O
R
P
E
R
TEMP/TIM
ER
hr
SET
SET/
O
F
F
C
A
N
C
EL
C
O
O
L
F
A
M
N
O
D
E
A
IR
S
W
IN
G
H
IG
E
C
H
O
M
E
D
F
A
N
S
P
E
E
D
LO
W
Wireless
Re
mote
Co
ntrol
A
T
IO
N
/O
N
N
O
M
Y
1 Cut the “Sealing Ribbon” to the
proper length, and attach it along
the bottom edge of the bottom
window sash.
2 To prevent condensation water
Window sash
sealing ribbon
from dripping inside, the cabinet
should be installed level or very
slightly tilted to the outside.
3 Secure the cabinet using screws.
Type A
screw
Type B
screws
Inside of
sash
Top angle
Outside of sash
Window sash
Sealing ribbon
Expandable panel
Window sill
Type A
screws
Window sash
foam seal
• Expand the expandable panel fully into the grooves of the
window frame, secure the expandable panel, left, right and
top mounting frames to the bottom of the window sash
using 4 screws type A and 2 screws type B.
• Secure the cabinet using wood screws type A.
• Cut the window sash foam seal to the proper size and
seal the opening between the top of the inside window
sash and the outside window sash.
Note :If a gap exists between the unit and window sash, you may
use “Sealer” supplied with the installation kit for a better seal.
INSERT THE AIR FILTER
Attach the air filter to the intake grille
PLACE FRONT INTAKE GRILLE OVER THE FRONT GRILLE
Slide the front intake grille slightly to the right to reattach the
tabs and then push it down to close tight.
Lift up about 90°.
2
OFF/ON
OPERATION
TEMP/TIMER
COOL
FAN
HIGH
MED
LOW
MODE
FAN SPEED
SET
TIMER
SET/
CANCEL
AIR SWING
ECONOMY
hr
°F
Wireless
Remote Control
REMOVAL OF FRONT GRILLE
1 Remove the front intake grille.
Pull up the front intake
grille about 90° and slide
it slightly to the left to
unhook the tabs.
°
F
T
I
M
E
OPERATION
R
T
E
M
P
/
T
I
M
E
R
h
r
S
E
T
OFF/ON
S
E
T
/
C
A
N
C
E
L
C
O
O
L
F
A
M
N
O
D
E
A
I
R
S
W
I
N
G
E
C
H
O
IG
N
H
O
M
Y
M
E
D
F
A
N
S
P
E
E
D
L
O
W
W
ireless
R
e
m
o
te
C
o
n
tr
o
l
2 Remove the air filter.
Tilt up and pull
out the air filter
by the holder.
3 Remove the front grille.
aa
a
Remove the adhesive tape from all sides of the front grille.
aabb
b
At bottom right side of the front grille, press inward on cabinet near the power cord, and pull
bb
the grille outward to the right until right tab releases.
cc
c
At the bottom left side, push inward on cabinet and pull the grille outward to the left to release
cc
the left tab.
Do not pull the bottom edge toward you more than 3 inches to prevent the two top tabs from
damage.
dd
d
Slide the front grille upwards to free the two top tabs from slots at the top of the cabinet.
dd
HOW TO ATTACH THE DRAIN PAN (OPTIONAL)
AIR CONDITIONER INSTALLATION
Condensed water drainage
This air conditioner employs a “Slinger-Up System” which is designed to splash the condensed
water on the condenser coil for maximum cooling efficiency, thus producing a splashing sound.
If the splashing sound annoys you, you can provide an outside drainage by using the following
procedure which may, however, cause a small loss of performance.
Note: The cabinet should be installed tilted slightly lower to the rear for necessary condensate
drainage. (Max. 13/32”)
1 Remove the rubber plug and slide the chassis out from
the cabinet.
3 Connect a drain hose (optional).
Fit the drain hose to the drain pan.
Note
OPERATION
ER
TIM
OFF/ON
T
E
S
R
E
IM
/T
/
P
°F
T
M
E
E
S
T
L
E
C
N
A
C
hr
Y
M
O
N
O
C
E
G
IN
W
S
IR
A
L
E
D
O
O
O
C
M
N
A
F
l
tro
n
Wireless
o
C
te
o
H
m
e
IG
R
H
D
E
E
P
S
N
A
F
D
E
M
W
O
L
Remove the
rubber plug
2 Install the optional drain pan (part no. CWH40175).
Install the drain pan at the right
corner of the cabinet using 2
INTERNAL VIEW
screws (part no. CWG86C733).
Note
The drain pan (part no.
CWH40175) can be obtained
from nearest servicenter.
Screws
Drain pan (optional)
Drain hose or tubing can be
purchased locally to satisfy your
particular needs.
4 Slide the chassis back into the
cabinet.
Reinstall the cabinet screws.
Secure the cabinet to chassis by
using screws.
Air filter
°
F
T
I
M
E
OPERATION
R
T
E
M
P
/
T
I
M
E
R
h
r
S
E
T
O
SE
FF/O
T/
N
C
A
N
CE
L
C
O
O
L
F
A
M
N
O
D
E
A
I
R
S
W
I
N
G
E
C
H
O
I
G
N
H
O
M
Y
M
E
D
F
A
N
S
P
E
E
D
L
O
W
W
ireless
R
e
m
o
te
C
o
n
tr
o
l
dd
d
dd
aa
a
aa
°
F
TIMER
O
P
E
R
A
T
IO
T
N
EM
P/TIM
ER
hr
S
E
T
SET/
O
F
F
/
O
N
CANCEL
C
O
O
LFA
MN
OD
E
AIRS
WIN
G
H
I
E
G
C
H
O
N
O
M
Y
M
E
D
F
A
N
S
P
E
E
D
L
O
W
W
ireless
Re
m
o
te
C
o
n
tro
cc
c
cc
l
bb
b
bb
Maximum
13/32”
Condensed water
EXTERNAL VIEW
Drain hose
(not included)
Under-side view with drain
pan and hose in place.
°
F
T
I
M
E
O
R
P
E
R
A
T
I
O
TEM
N
P/TIM
ER
h
r
S
ET
S
OFF/ON
E
T
/
C
A
N
C
E
L
COOL
FAN
MODE
AIR SWING
HIGH
ECONOMY
MED
FAN SPEED
LOW
W
ire
le
ss
R
e
m
o
te
C
o
n
tr
o
l
3
MAIN UNIT
1
2
6
7
4
8
5
9
3
1 Air inlet louver4 Air filter
2 Cabinet5 Front intake
3 Power cord6 Front grille
7 Vertical airflow direction vane
(Airflow direction adjustment up-down).
The vertical airflow direction
vane is controlled by
rotating the horizontal vane
forward or backward.
8 Ventilation lever
The ventilation lever must be in the CLOSE position in order
to maintain the best cooling conditions. When fresh air is
°F
T
IM
E
O
R
P
E
R
A
TEMP/TIMER
T
IO
N
hr
SET
S
E
OFF/ON
T
/
C
A
N
C
E
COOL
L
FAN
MODE
AIR SWING
HIGH
MED
PART IDENTIFICATION
LOW
TYPES OF SIGNAL SOUND
One long “Beep” and one short “Beep”. (Sound from the main unit.)
necessary in the room, set the ventilation lever to the OPEN
E
C
O
N
O
M
Y
FAN SPEED
Wireless
Rem
ote Control
position. The damper is opened and room air is drawn out.
grille
9 Touch control panel
e
d
a
b
g
f
i
h
c
a Display Panel
b MODE selection pad
°
F
TIMER
O
P
E
R
A
T
T
E
IO
M
N
P
/T
I
M
E
R
h
r
S
E
T
S
E
OFF/ON
T
/
C
A
N
C
E
L
C
O
O
L
F
A
M
N
O
D
E
A
IR
S
W
IN
G
H
IG
H
E
C
O
N
O
M
Y
M
E
D
F
A
N
S
P
E
E
D
L
O
W
W
ireless
R
e
m
o
te
C
o
n
t
r
o
l
c FAN SPEED selection pad
d TEMPERATURE/TIMER
setting pad
e TIMER pad
f Timer SET/CANCEL pad
g OPERATION OFF/ON pad
h AIR SWING pad
i ECONOMY pad
• Aim remote control at control
panel on air conditioner when
operating.
• Do not drop or throw the remote
3
5
7
9
control.
• Do not place the remote control
in a location that is exposed to
direct sunlight or next to a heating
unit or other heat sources.
• Maximum distance : 10 m
°F
T
I
M
E
R
O
P
E
R
A
TEMP/TIMER
T
IO
N
hr
SET
S
E
O
T
F
/
F
/O
N
C
A
N
C
E
L
COOL
FAN
MODE
AIR SWING
HIGH
E
C
O
N
O
M
Y
MED
FAN SPEED
LOW
W
ireless
R
e
m
o
te
C
o
n
tro
l
4
HOW TO INSERT BATTERIES
OPERATING
1
Open the cover.
PREPARATION BEFORE
5
CAUTION
OPERATING THE UNIT
OPERATION
OFF/ON
OPERATION
SETTING DISPLAY TEMPERATURE
TEMP/TIMER
TEMP/TIMER
WARNING
Ensure that the power
plug is securely inserted.
A loose plug may cause a
fire or an electric shock.
2
Insert the two batteries.
NOTES
• If the unit is not going to be used for an extended period of time, remove the
power plug. Otherwise, approximately 2.5W of electricity will be used even if the
unit has been turned off using the remote control.
• If operation is stopped, and to be restarted immediately, the unit will resume
operation only after 3 minutes.
3
Close the cover.
Do not use rechargeable (Ni-Cd) batteries
because such batteries differ from the standard
dry cell batteries in shape, dimension and
performance.
Start operation by pressing
°F
hr
OPERATION.
The operation will turn on and the
display panel will light up.
°F
hr
To stop the operation, press the
OPERATION again.
The unit will stop operating and the
display panel light will turn off.
Press TEMP/TIMER ▲ or ▼ to set the
°F
hr
display temperature.
Display will
change
according to
the setting.
The temperature can be set between
60°F and 86°F.
Recommended temperature:
75°F ~ 78°F.
ABOUT THE BATTERIES
• The batteries can be used for approximately one year.
• Be sure to replace the batteries with two new identical
batteries.
• Remove the batteries if the air conditioner will not be used
for an extended period of time.
SELECTING OPERATION MODE
HIGH
FAN SPEED
MED
LOW
Press MODE to select the desired
operation .
COOL
The indicator will light up and a “beep”
FAN
sound will indicate changing setting.
COOL mode
To set room temperature to your
preference of cooling comfort.
FAN mode
T o provide air circulation without cooling
the room.
During Fan operation, temperature
setting cannot be selected.
AIR CONDITIONER OPERATION
NOTES
• The latest temperature setting will be memorized and will
appear on the display the next time it’s turned on.
• The display temperature selection is for display purpose only
and does not indicate actual room setting temperatures. Your
room temperature may not necessarily match the displayed
temperature.
SELECTING FAN SPEED
Press FAN SPEED to choose the
HIGH
speed level of the fan.
The indicator will light up and the “beep”
MED
FAN SPEED
sound will indicate changing setting.
LOW
NOTE
• The latest fan speed setting will be memorized and the indicator
will light up the next time the unit is turned on.
ADJUSTING HORIZONTAL AIR FLOW DIRECTION
Press to select AIR SWING.
The air circulation will automatically move the
horizontal louvers left and right for better air
distribution around the room.
NOTE
Using your hands to adjust the direction may cause
the louvers to malfunction. If this happens, stop
operation immediately and restart.
NOTE
Vertical
louvers
°
F
T
IM
E
OPERATION
R
TEMP/TIMER
h
r
SET
S
E
OFF/ON
T
/
C
A
N
C
E
C
L
O
O
L
F
A
M
N
O
D
E
A
IR
S
W
IN
G
H
IG
H
E
C
O
N
O
M
Y
M
E
D
F
A
N
S
P
E
E
D
L
O
W
W
ireless
Remote Control
Vertical adjustment of the airflow direction
is done manually.
Loading...
+ 11 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.