Thank you for purchasing Panasonic Air Conditioner.
Installation instructions attached.
Before operating the unit, read these operating
instructions thoroughly and keep them for future
reference.
English
F570018
Page 2
Provide fast cooling, maximum comfort,
clean air and optimise energy saving
i AUTO-X Cooling when it counts, Comfort when it matters
i AUTO-X with the new Panasonic Thermal Enhancement Technology (P-TECh) is a unique Panasonic
compressor control technology which enable compressor to achieve maximum frequency in a short time.
i AUTO-X also comes with new AEROWINGS - twin fl aps that works dynamically to adjust airfl ow
directions. AEROWINGS gives you fast cooling at start up by directing airfl ow downwards*, and comfort
of shower cooling by directing airfl ow upwards*.
So, you get to enjoy instant fast cooling satisfaction on a hot day and cooling comfort that goes on all
day long.
*Applicable for horizontal fl ap AUTO setting.
ECONAVI + INVERTER The Perfect Energy Saving Technology
ECONAVI detects where energy is normally wasted and adjusts cooling/heating power depending on
room conditions and activity levels. Then, INVERTER leverages ECONAVI sensor data and varies
compressor rotation speed. This helps to optimize cooling/heating operation and reduces wasteful
cooling/heating.
nanoe-G Purifi es the air down to the smallest particles
Deactivates harmful micro-organisms such as viruses, bacteria, etc. to keep air clean.
It also deactivates viruses and bacteria on the fi lter to keep inside of the unit clean.
See “To learn more...” for details.
2
Page 3
Quick guide
S
CK
RES
AC
RC
ON
O
CANCEL
1
3
TIMER
K
A
R
CK
R
C
RC
ON
OFFS
CANCEL
1
2
3
TIMER
I
NANOE-G
D
A
G
i
A
UTO
MILD DRY
MILD
DRY
Inserting the batteries
1
3
23
TIMER
1
2
1
3
ON
OFF
ETCHE
i AUTO-X
AUTO-X
MODE
MILD DRY
POWERFUL/QUIET
POWERFUL/QUIET
TIMER
ON
OFF
SETCHECKRESET
SETCHE
SET
123
CANCEL
FF
AIR CONDITIONER
IR CONDITIONE
AUTO
123
AC
CLOCKSETCHECKRESET
MODE
MODE
OFF/ON
TEMP
AIR SWING
FAN SPEED
FAN SPEE
AC
A
CLOCK
CLOC
ET
MILDDRY
ECONAVI
ECONAV
NANOE-G
IR SWIN
SET
ET
CANCEL
ESET
RC
RC
The illustrations in this manual are for explanation purposes
only and may differ from the actual unit. They are subject to
change without notice for future improvement.
1
2
Pull out the back cover of
remote control
Insert AAA or R03 batteries
2
(can be used ~ 1 year)
3
Close the cover
Clock setting
1
Press CLOCK
2
Set the time
3
Confi rm
Basic operation
Select the desired mode
1
AUTOHEATCOOL
Start/stop the operation
2
POWER
• Please note that the OFF
indication is on to start.
3
Select the desired
temperature
• Selection range: 16 °C ~
30 °C (Not applicable for
FAN mode).
•
Operating the unit within the
recommended temperature
may save energy.
HEAT : 20 °C ~ 24 °C.
COOL: 26 °C ~ 28 °C.
DRY : 1 °C ~ 2 °C lower than
room temperature.
8m
• To dim or restore the unit’s
indicator brightness, press
and hold for 5 seconds.
• Use remote control within 8 m
from the remote control receiver
of the indoor unit.
FANi AUTO-XDRY
Table of contents
Safety precautions ...................4-5
How to use...............................6-7
To learn more... ......................8-9
Cleaning instructions ................10
Troubleshooting ........................ 11
Information.................Back cover
Accessories
• Remote control
• AAA or R03 batteries × 2
• Remote control holder
• Screws for remote control
holder × 2
This symbol shows
that this equipment
uses a fl ammable
WARNING
CAUTION
CAUTION
CAUTION
CAUTION
refrigerant. If the
refrigerant is
leaked, together
with an external
ignition source,
there is a
possibility of
ignition.
This symbol shows
type of fl ammable
refrigerant
contained in the
system.
This symbol shows
that the Operation
Instructions should
be read carefully.
This symbol shows
that a service
personnel should
be handling this
equipment with
reference to the
Installation
Instructions.
This symbol
shows that there
is information
included in
the Operation
Instructions and/
or Installation
Instructions.
English
3
Page 4
Safety precautions
To prevent personal injury, injury to others or
property damage, please comply with the following:
Incorrect operation due to failure to follow
instructions below may cause harm or damage, the
seriousness of which is classifi ed as below:
This appliance is fi lled with R32
(mild fl ammable refrigerant). If the
refrigerant is leaked and exposed to
an external ignition source, there is a
risk of fi re.
WARNING
CAUTION
The instructions to be followed are classifi ed by the
following symbols:
Indoor unit
Air outletAir outlet
Remote control
Outdoor unit
This sign warns of
death or serious injury.
This sign warns of
injury or damage to
property.
This symbol denotes an action
that is PROHIBITED.
These symbols denote actions
COMPULSORY.
Power supply
Air inletAir inlet
Air inletAir inlet
Air outletAir outlet
WARNING
Indoor unit and outdoor unit
This appliance is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience
and knowledge, unless they have been given
supervision or instruction concerning use of the
appliance by a person responsible for their safety.
Children should be supervised to ensure that they
do not play with the appliance.
The appliance shall be installed and operated in a
room with fl oor area larger than 2.06m² and keep
away from ignition sources (such as heat/sparks/
open-fl ame) or, hazardous areas (such as gas
appliances, gas cooking, reticulated gas supply
systems, or electric cooling appliance, etc.
(Refer to the Installation Instruction table A
Be aware that refrigerant may not contain an odour,
highly recommended to ensure suitable fl ammable
refrigerant gas detectors are present, operating and
able to warn of a leak.
Please consult authorised dealer or specialist to
clean the internal parts, repair, install, remove and
reinstall the unit. Improper installation and handling
will cause leakage, electric shock or fi re.
Confi rm with authorised dealer or specialist on
usage of any specifi ed refrigerant type.
Using refrigerant type other than the specifi ed may
cause product damage, burst and injury etc.
Do not use means to accelerate the defrosting
process or to clean, other than those recommended
by manufacturer. Any unfi t method or using in-
compatible material may cause product damage,
burst and serious injury.
Do not pierce or burn as the appliance is
pressurized. Do not expose the appliance to heat,
fl ame, sparks, or other sources of ignition. Else it
may explode and cause injury or death.
Do not install the unit in a potentially explosive or
fl ammable atmosphere. Failure to do so could result
in fi re.
Do not insert your fi ngers or other objects
into the air conditioner indoor or outdoor
unit, rotating parts may cause injury.
Do not touch the outdoor unit during lightning, it
may cause electric shock.
Do not expose yourself directly to cold air for a long
period to avoid excess cooling.
Do not sit or step on the unit, you may fall
down accidentally.
min
(m²))
4
Page 5
Remote control
Do not allow infants and small children to play
with the remote control to prevent them from
accidentally swallowing the batteries.
Power supply
Do not use a modifi ed cord,
joint cord, extension cord or
unspecifi ed cord to prevent
overheating and fi re.
To prevent overheating, fi re or electric shock:
•
Do not share the same power outlet with other
equipment.
•
Do not operate with wet hands.
•
Do not over bend the power supply cord.
•
Do not operate or stop the unit by inserting or
pulling out the power plug.
If the supply cord is damaged, it must be
replaced by the manufacturer, service agent or
similarly qualifi ed persons in order to avoid a
hazard.
It is strongly recommended to be installed
with Earth Leakage Circuit Breaker (ELCB)
or Residual Current Device (RCD) to prevent
electric shock or fi re.
To prevent overheating, fi re or electric shock:
•
Insert the power plug properly.
•
Dust on the power plug should be periodically
wiped with a dry cloth.
Stop using the product if any abnormality/failure
occurs and disconnect the power plug or turn off
the power switch and breaker.
(Risk of smoke/fi re/electric shock) Examples of
abnormality/failure
•
The ELCB trips frequently.
•
Burning smell is observed.
•
Abnormal noise or vibration of the unit is
observed.
•
Water leaks from the indoor unit.
•
Power cord or plug becomes abnormally hot.
•
Fan speed cannot be controlled.
•
The unit stops running immediately even if it is
switched on for operation.
•
The fan does not stop even if the operation is
stopped.
Contact your local dealer immediately for
maintenance/repair.
This equipment must be earthed to prevent
electrical shock or fi re.
Prevent electric shock by switching off the power
supply and unplug:
- Before cleaning or servicing,
- When extended non-use, or
- During abnormally strong lightning activity.
CAUTION
Indoor unit and outdoor unit
Do not wash the indoor unit with water, benzine,
thinner or scouring powder to avoid damage or
corrosion at the unit.
Do not use for preservation of precise equipment,
food, animals, plants, artwork or other objects.
This may cause quality deterioration, etc.
Do not use any combustible equipment in front of
the airfl ow outlet to avoid fi re propagation.
Do not expose plants or pet directly to airfl ow to
avoid injury, etc.
Do not touch the sharp aluminium fi n,
sharp parts may cause injury.
Do not switch ON the indoor unit when waxing
the fl oor. After waxing, aerate the room properly
before operating the unit.
Do not install the unit in oily and smoky areas to
prevent damage to the unit.
Do not dismantle the unit for cleaning purpose to
avoid injury.
Do not step onto an unstable bench when
cleaning the unit to avoid injury.
Do not place a vase or water container on the
unit. Water may enter the unit and degrade the
insulation. This may cause an electric shock.
Do not open window or door for long time during
operation, it may lead to ineffi cient power usage
and uncomfortable temperature changes.
Prevent water leakage by ensuring drainage
pipe is:
- Connected properly,
- Kept clear of gutters and containers, or
- Not immersed in water
After a long period of use or use with any
combustible equipment, aerate the room
regularly.
After a long period of use, make sure the
installation rack does not deteriorate to prevent
the unit from falling down.
Safety precautions
English
Remote control
Do not use rechargeable (Ni-Cd) batteries. It may
damage the remote control.
To prevent malfunction or damage of the remote
control:
•
Remove the batteries if the unit is not going to
be used for a long period of time.
•
New batteries of the same type must be
inserted following the polarity stated.
Power supply
Do not disconnect the plug by pulling the cord to
prevent electric shock.
5
Page 6
How to use
K
O
ON
CHECK
ON
OFFS
CANCEL
1
2
3
TIMER
TEMP
i AUTO-X
To reach temperature quickly
(Cooling only)
i AUTO-X
•
The unit controls set temperature according to room
temperature to accelerate room cooling.
i AUTO-X
•
After max 4 hours, the set temperature is shifted
Set
temperature
-1°C
Max = 4 hours
according to activity detection.
•
Fan speed is fi xed at AUTO, fan speed selection is
prohibited.
•
During unit is off, press
i AUTO-X
will turn on the unit
with i AUTO-X mode.
•
i AUTO-X mode can be cancelled by pressing the
respective button again.
MODE
To select operation mode
AUTO - For your convenience
HEAT - To enjoy warm air
COOL - To enjoy cool air
DRY - To dehumidify the environment
FAN - To circulate air in the room
i AUTO-X - To reach temperature quickly (Cooling only)
To improve humidity and
MILD DRY
moisture level
•
This operation reduces air dryness and provides you
with a comfortable living environment during COOL
mode only.
•
When vertical airfl ow direction is set to AUTO, it
stops at lower position to avoid cold air contact.
However, you can adjust the louver direction
manually.
POWERFUL/QUIET
To switch between powerful &
quiet
QUIETPOWERFULNORMAL
POWERFUL: To reach temperature quickly
POWERFUL
•
This operation stops automatically after 4 hours.
QUIET: To enjoy quiet operation
QUIET
•
This operation reduces airfl ow noise.
Sunlight sensor
and remote
control receiver
i AUTO-X
POWERFUL
Indicator
Human activity
sensor
Remote control
display
AIR CONDITIONER
MODE
AUTO
i AUTO-X
OFF/ON
FF/
MODE
TEMP
MILD DRY
POWERFUL/QUIET
FAN SPEED
TIMER
ON
123
OFF
CLOCK
SET CHECKRESET
CLOC
MILD
DRY
ECONAVI
NANOE-G
AIR SWING
SET
ET
CANCEL
RC
AC
POWER
TIMER
i AUTO-X
NANOE-G
POWERFUL
QUIET
Press and hold for
approximately
10 seconds to show
temperature setting in
°C or °F.
Press to restore the
remote control to
default setting.
For AUTO, the indoor fan speed is automatically
adjusted according to the operation mode.
•
If i AUTO-X mode is set, fan speed is fi xed to AUTO.
To adjust fan speed, cancel i AUTO-X mode.
Auto OFF/ON button
6
Use when remote control is misplaced or a malfunction occurs. Raise the front panel:
• To use in AUTO mode, press the button once.
• To use in COOL mode, press and hold the button until 1 beep is heard, then
release.
• To use in HEAT mode, press and hold the button until 1 beep is heard, then
release. And press again until 2 beeps are heard, then release.
• Press the button again to turn off.
Page 7
See "To learn more..." for details.
CANCEL
3
TIMER
ECONAVI
NANOE-G
•
•
To optimise energy saving
To purify the air
NANOE-G
nanoe-G starts automatically when the unit is turned
OFF/ON
on with
Can be activated even when the unit is turned off. In
or timer ON is activated.
this condition, the unit will operate as a fan with AUTO
fan speed and fl ap swing.
To deactivate viruses/bacteria on the fi lter
NANOE-G
•
After the unit is turned off, the nanoe-G in-fi lter
deactivation may activate up to 150 minutes. Turning
on the unit cancels this operation.
•
To disable this operation in the future, press and hold
NANOE-G
until a short beep sound is heard. This will not
disable the nanoe-G to purify the air.
•
To restore the nanoe-G in-fi lter deactivation, press and
NANOE-G
hold
AIR SWING
(Remote control display)
•
Keeps the room ventilated.
•
In COOL/DRY mode, if AUTO is set, the fl aps swings
left/right and up/down automatically.
•
In HEAT mode, if AUTO is set, the horizontal fl ap is fi xed at the predetermined position. The vertical fl ap
swings left/right after the temperature rises.
•
In i AUTO-X mode, if AUTO is set, the horizontal fl ap
is fi xed at the lower position and shift to the upper
position after reaches set temperature. The vertical
fl ap movement depends on human activity sensor.
•
If manual is set, the horizontal and vertical fl ap are fi xed at the predetermined position.
•
Do not adjust the fl ap by hand.
POWER
until a long beep sound is heard.
To adjust airfl ow direction
Auto Restart Control
• If power is resumed after a power failure, the
operation will restart automatically after a period
of time with previous operation mode and airfl ow
direction.
• This control is not applicable when TIMER is set.
To set the timer
2 sets of ON and OFF timers are available
to turn ON or OFF the unit at different preset
times.
123
TIMER
ON
123
OFF
Select ON or OFF
1
timer
• Each time pressed:
Set the time
2
Confi rm
3
SET
CANCEL
Example:
OFF at 22:00
OFF
Cancel
2
SET
TIMER
• To cancel ON or OFF timer, press ON or
to select respective or then press
• If timer is cancelled manually or due to power
failure, you can restore the timer again by
pressing ON or
then press
OFF
to select respective or
SET
.
• The nearest timer setting will be displayed and
will activate in sequence.
• When ON Timer is set, the unit may start
earlier (up to 35 minutes) before the actual
set time in order to achieve the desired
temperature on time.
• Timer operation is based on the clock set in
the remote control and repeats daily once set.
For clock setting, please refer to Quick guide.
OFF
CANCEL
.
Note
ECONAVI
• Can be activated in HEAT, COOL and DRY
• Cannot be selected at the same time.
• Cannot be activated during MILD DRY.
POWERFUL/QUIET
,
NANOE-G
,
mode and can be cancelled by pressing the
respective button again.
i AUTO-X
ECONAVI
,
POWERFUL/QUIET
,
How to use
English
7
Page 8
To learn more...
Operation mode
AUTO : During operation mode selection the POWER indicator blinks.
• Unit selects operation mode every 10 minutes according to setting temperature and room temperature.
HEAT : Unit takes a while to warm up. The POWER indicator blinks during this operation.
COOL : Provides effi cient comfort cooling to suit your needs.
DRY : Unit operates at low fan speed to give a gentle cooling operation.
FAN : To circulate air in the room.
i AUTO-X : The fast cooling is ideal when you come home on a hot day.
nanoe-G in-fi lter deactivation
Depending on the unit’s accumulated operation time, nanoe-G in-fi lter deactivation may activate only once a day after
the unit turned off.
To remove the moisture left in the internal parts, the fan will operate for 30 minutes with fl ap opened slightly. This
process only applicable when the unit is operated in COOL/DRY mode before turned off.Then, nanoe-G deactivates
viruses/bacteria on the fi lter for 2 hours with fan stopped and fl ap closed.
Do not turn off the power supply during this operation. After power failure, this operation will not resume.
ECONAVI
ECONAVI
The unit will start to initialise
(for approximately 1 minute)
The human activity sensor
and the sunlight sensor will
start to detect.
Human activity sensor operation
ECONAVI ; Detecting human presence and activity, the unit controls room temperature to save energy.
Mode
COOL/DRY
HEAT
Human
Set
temperature
Low activityNormal activity
+1 °C
Note
AIR SWING
When manual AIR SWING is selected,
the ECONAVI operations will be
cancelled.
High activityAbsent
+2 °C
-2 °C-2 °C
ECONAVI
Precise control of temperature during low activity to maximise energy saving.
Mode
COOL/DRY
Human
Set
temperature
Low activity
ECONAVI take advantage of the human nature that
human being takes time to feel the temperature rise
during low activity level; the unit adjusts temperature to
maximise energy saving without sacrificing the comfort.
Sunlight Sensor operation
ECONAVI ; Detecting sunlight intensity, the unit adjust temperature to save energy.
Mode
COOL/DRY
HEAT
• In a room without window or with thick curtain, the sunlight sensor will judge as cloudy/night.
Ambient condition
+1 °C
Set
temperature
-1 °C-1 °C
8
ECONAVI is activated,
the unit maintains set
temperature until a high
sunlight intensity is detected.
The sunlight sensor detects
sunlight intensity during
weather or day/night
changes, and the unit adjusts
temperature.
Page 9
The human activity sensor will also scan for area of heat source and movement in a room.
Detection area
120º
7m
• The human activity sensor may:
- mistakenly detect an object with heat source & movement similar to human, such as pets, etc.
- mistakenly detect as non-heat source & movement if a human stays motionless for certain period of time.
• Do not place large objects near the sensor and keep away heating units or humidifi er from the sensor’s detection
area. They may cause sensor malfunction.
• Based on area activeness horizontal airfl ow direction will adjust either fi x
at predetermined position or swing left/right periodically.
• The human activity sensor performance is infl uenced by indoor unit
location, movement speed, temperature range, etc.
i AUTO-X
i AUTO-X ; Fast cooling to maximum of 4 hours, the unit continue to provide cooling comfort according human
presence and activity detection.
Mode
i AUTO-X
Human
Set
temperature
Low activityNormal activity
+1 °C
High activityAbsent
+2 °C
-1 °C
Operation conditions
Use this air conditioner under the following temperature range.
DBT : Dry bulb temperature
WBT : Wet bulb temperature
Temperature (°C)
COOL
HEAT
Max.32234626
Min.16115-
Max.30-2418
Min.16--15-
IndoorOutdoor
DBTWBTDBTWBT
To learn more...
English
9
Page 10
Cleaning instructions
To ensure optimal performance of the unit,
cleaning has to be carried out at regular
intervals. Dirty unit may cause malfunction
and you may see nanoe-G indicator blinks or
error code “H99”. Please consult authorised
dealer.
• Switch off the power supply and unplug before
cleaning.
• Do not touch the aluminium fi n, sharp parts may
cause injury.
• Do not use benzine, thinner or scouring powder.
• Use only soap (
pH 7) or neutral household
detergent.
• Do not use water hotter than 40 °C.
Indoor unit
Wipe the unit gently with a soft,
dry cloth.
Human activity sensor
Do not hit or violently press or poke it with a sharp
object. This can lead to damage and malfunction.
Outdoor unit
Clear debris that surround the unit.
Clear any blockage from drain
pipe.
Front panel
Wash gently and dry.
Remove the front panel
Pull out
2
Indoor unit
Aluminium fi nFront panel
POWER
TIMER
i AUTO-X
NONOE-G
POWERFUL
QUIET
Human activity
sensor
Air fi lters
nanoe-G
Generator
nanoe-G Generator
Every 2 weeks
• Clean with dry cotton bud.
• Do not touch during operation.
Air fi lters
Every 2 weeks
• Wash/rinse the fi lters gently
with water to avoid damage to
the fi lter surface.
• Dry the fi lters thoroughly under shade, away
from fi re or direct sunlight.
• Replace any damaged fi lters.
Remove air fi lterAttach air fi lter
Raise
1
Close it securely
Close down
2
Press both ends of the front panel
3
For CS-Z18RKR, CS-Z21RKR,
4
CS-Z24RKR, CS-Z28RKR:
Press at center of the front panel.
10
POWER
TIMER
i AUTO-X
NONOE-G
POWERFUL
QUIET
Insert into the unit
For seasonal inspection after extended
non-use
Insert at both sides1
• Checking of remote control batteries.
• No obstruction at air inlet and air outlet vents.
• Use Auto OFF/ON button to select COOL/
HEAT operation. After 15 minutes of
operation, it is normal to have the following
POWER
TIMER
i AUTO-X
NONOE-G
POWERFUL
QUIET
temperature difference between air inlet and
air outlet vents:
COOL: ≥ 8 °C HEAT: ≥ 14 °C
For extended non-use
•
Activate HEAT mode for 2~3 hours to remove
moisture left in the internal parts thoroughly to
prevent mould growth.
• Turn off the power supply and unplug.
• Remove the remote control batteries.
Page 11
Troubleshooting
K
SETRES
AC
RC
ON
O
S
CANCEL
1
3
TIMER
The following symptoms do not indicate malfunction.
SymptomCause
Mist emerges from indoor unit.
Water fl owing sound during operation.
The room has a peculiar odour.
Indoor fan stops occasionally during automatic fan
speed setting.
Airfl ow continues even after operation has stopped.• Extraction of remaining heat from the indoor unit
Operation is delayed a few minutes after restarting.
Outdoor unit emits water/steam.
TIMER indicator is always on.
POWER indicator blinks during HEAT mode with no
warm air supply (and fl ap is closed).
Indoor fan stops occasionally during heating
operation.
POWER indicator blinks before the unit is switched
on.
Cracking sound during operation.
Discoloration of some plastic parts.
Louder noise at outdoor unit during early
operation of i AUTO-X.
Dust may have collected around the front panel,
grilles and wall surrounding the unit after extended
use.
Check the following before calling for servicing.
SymptomCheck
Operation in HEAT/COOL mode is not working
effi ciently.
Noisy during operation.
Remote control does not work.
(Display is dim or transmission signal is weak.)
The unit does not work.
The unit does not receive the signal from the
remote control.
NON SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY AND
UNPLUG then please consult authorised
dealer under the following conditions:
• Abnormal noise during operation.
• Water/foreign particles have entered the
remote control.
• Water leaks from Indoor unit.
• Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.
• Switches or buttons are not functioning
properly.
•
Condensation effect due to cooling process.
•
Refrigerant fl ow inside the unit.
•
This may be due to damp smell emitted by the wall, carpet,
furniture or clothing.
•
This helps to remove the surrounding odour.
(maximum 30 seconds).
•
The delay is a protection to the unit’s compressor.
•
Condensation or evaporation occurs on pipes.
•
The timer setting repeats daily once set.
•
The unit is in defrost mode (and AIR SWING is set to AUTO).
•
To avoid unintended cooling effect.
•
This is a preliminary step in preparation for the operation
when the ON timer has been set.
•
Changes of temperature caused the expansion/contraction
of the unit.
•
Discoloration is subject to material types used in plastic parts,
accelerated when exposed to heat, sun light, UV light, or
environmental factor.
•
The compressor and fan rotate at higher speed to boost
cooling performance during initial operation.
•
The dust accumulation is due to air purifi cation effect of
negative ions from nanoe-G. Remove the dust regularly with
a clean dampened cloth.
•
Set the temperature correctly.
•
Close all doors and windows.
•
Clean or replace the fi lters.
•
Clear any obstruction at the air inlet and air outlet vents.
•
Check if the unit has been installed at an incline.
•
Close the front panel properly.
•
Insert the batteries correctly.
•
Replace weak batteries.
•
Check if the circuit breaker is tripped.
•
Check if timers have been set.
•
Make sure the receiver is not obstructed.
•
Certain fl uorescent lights may interfere with signal transmitter.
Please consult authorised dealer.
The unit stops and the TIMER indicator blinks.
Use remote control to retrieve error code.
Press for
5 seconds
3
Press for
5 seconds
to quit
checking
TIMER
ON
123
OFF
FF
CANCEL
AC
CLOCKSET CHECKRESET
CLOC
SET
ET
RC
ET
• For certain errors, you may restart the unit for limited
operation with 4 beeps when operation starts.
21
Press until you
hear beep sound,
then write down
the error code
4
Turn the unit off
and reveal the
error code to
authorised dealer
Cleaning instructions / Troubleshooting
English
11
Page 12
Information
Information for Users on Collection and Disposal of Old Equipment and used Batteries
[Information on Disposal in other Countries outside the European Union]
These symbols are only valid in the European Union. If you wish to discard
these items, please contact your local authorities or dealer and ask for the
correct method of disposal.
Note for the battery symbol (bottom two symbol examples):
This symbol might be used in combination with a chemical symbol. In this case
it complies with the requirement set by the Directive for the chemical involved.