NOTA: As ilustrações deste manual têm apenas como caráter explicativo e podem diferir da unidade real. Estão
sujeitas a alterações sem aviso prévio para ns de melhoramento.
2
OPERATION CONDITION
Use this air conditioner under the following temperature range
Temperature (°C)
COOLING
Max.32234326
Min.16111611
IndoorOutdoor
*DBT*WBT*DBT*WBT
CONDIÇÃO DE FUNCIONAMENTO
Utilize este condicionador de ar com o seguinte intervalo de temperaturas
Temperatura (°C)
RESFRIAMENTO
Máx.32234326
InternaExterna
*DBT*WBT*DBT*WBT
Mín.16111611
* DBT: Dry bulb temperature
* WBT: Wet bulb temperature
* DBT: Temperatura de bulbo Seco
* WBT: Temperatura de bulbo úmido
3
SAFETY PRECAUTIONS
To prevent personal injury, injury to others, or property
damage, please comply the following.
Incorrect operation due to failure to follow instructions
may cause harm or damage, the seriousness of which is
classied as below:
WARNING
This sign warns of death or serious injury.
CAUTION
This sign warns of injury or damage to property.
The instructions to be followed are classied by the following
symbols:
This symbol denotes an action that is
PROHIBITED
These symbols denote an action that is
COMPULSORY.
WARNING
INDOOR UNIT AND OUTDOOR UNIT
This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have
been given supervision or instruction concerning
use of the appliance by a person responsible for
their safety. Children should be supervised to
ensure that they do not play with the appliance.
Please consult authorized dealer or specialist to
clean the internal parts, repair, install, remove
and reinstall the unit. Improper installation and
handling will cause leakage, electric shock or
re.
Do not install the unit in a potentially explosive
or ammable atmosphere. Failure to do so could
result in re.
Do not insert your ngers or other
objects into the air conditioner indoor
or outdoor unit, rotating parts may
cause injury.
Do not touch the outdoor unit during lightning, it
may cause electric shock.
Do not expose yourself directly to cold air for a
long period to avoid excess cooling.
Do not sit or step on the unit, you
may fall down accidentally.
Remote
Control
Indoor
Unit
Air OutletAir Outlet
Air Inlet
Outdoor
Unit
Air Inlet
Power
Supply
Air Outlet
REMOTE CONTROL
Do not allow infants and small children to play
with the remote control to prevent them from
accidentally swallowing the batteries.
POWER SUPPLY
Do not use modied cord,
joint cord, extension cord or
unspecied cord to prevent
overheat and re.
To prevent overheating, re or electric shock:
• Do not share the same power outlet with other
equipment.
• Do not operate with wet hands.
• Do not over bend the power supply cord.
• Do not operate or stop the unit by inserting or
pulling out the power plug.
4
WARNING
CAUTION
POWER SUPPLY
If the supply cord is damage, it must be
replaced by the manufacturer, its service agent
or similarly qualied persons in order to avoid
a hazard.
It is strongly recommended to be installed
with Earth Leakage Circuit Breaker (ELCB)
or Residual Current Device (RCD) to prevent
electric shock or re.
To prevent overheating, re or electric shock:
• Insert the power plug properly.
• Dust on the power plug should be periodically
wiped with a dry cloth.
Stop using the product when any abnormality/
failure occurs and disconnect the power plug or
turn off the power switch and breaker.
(Risk of smoke/re/electric shock)
Examples of abnormality/failure
• The ELCB trips frequently.
• Burning smell is observed.
• Abnormal noise or vibration of the unit is
observed.
• Water leaks from the indoor unit.
• Power cord or plug becomes abnormally hot.
• Fan speed cannot be controlled.
• The unit stops running immediately even if it is
switched on for operation.
• The fan does not stop even if the operation is
stopped.
Contact immediately your local dealer for
maintenance/repair.
Replacement or installation of power plugs shall
be performed by authorized/qualied personnel
only. The wires in this mains lead are coloured
in accordance with the following code:
Terminals
Red
Black
Green/Yellow
Wiring colour may vary depending on a country
wiring code’s standard.
This equipment must be earthed to prevent
electric shock or re.
wires
colours (IEC Standard)
live
brown
neutral
blue
earth
green-yellow
INDOOR UNIT AND OUTDOOR UNIT
Do not wash the indoor unit with water,
benzene, thinner or scouring powder to avoid
damage or corrosion at the unit.
Do not use for preservation of precise equipment,
food, animals, plants, artwork or other objects.
This may cause quality deterioration, etc.
Do not use any combustible equipment in front
of the airow outlet to avoid re propagate.
Do not expose plants or pet directly to airow to
avoid injury, etc.
Do not touch the sharp aluminium n,
sharp parts may cause injury.
Do not switch ON the indoor unit when waxing
the oor. After waxing, aerate the room properly
before operating the unit.
Do not install the unit in oily and smoky areas to
prevent damage to the unit.
Do not dismantle the unit for cleaning purpose
to avoid injury.
Do not step onto unstable bench when cleaning
the unit to avoid injury.
Do not place vase or water container on the
unit. Water may enter the unit and degrade the
insulation. This may cause an electric shock.
Do not left the window open during Cool/Dry
mode operation to prevent water leakage.
Ensure drainage pipe is connected properly and
keep drainage outlet clear of gutters, containers
or does not immersed in water to prevent water
leakage.
After long period of use or use with any
combustible equipment, aerate the room
regularly.
After long period of use, make sure the
installation rack is not deteriorate to prevent the
unit from falling down.
REMOTE CONTROL
Do not use rechargeable (Ni-Cd) batteries.
It may damage the remote control.
ENGLISH
Prevent electric shock by switching off the
power supply and unplug when:
- Before cleaning or servicing.
- Extended non-use.
- Abnormally strong lightning activity.
To prevent malfunction or damage of the remote
control:
• Remove the batteries if the unit is not going to
be used for a long period of time.
• New batteries of the same type must be
inserted following the polarity stated.
POWER SUPPLY
Do not pull the cord to disconnect the plug to
prevent electric shock.
5
REMOTE CONTROL
FAN SPEED
AIR SWING
4
TO SELECT FAN SPEED (3 OPTIONS)
Maximum distances: 8m
AUTO
COOL
DRY
FAN
FAN
SPEED
AIR
SWING
RESET
AIR CONDITIONER
(GREEN)
(ORANGE)
Press the remote control’s button
1
TO TURN ON OR OFF THE UNIT
• Please be aware of the OFF indication on the remote
control display to prevent the unit from starting/stopping
improperly.
2
TO SET TEMPERATURE
• Selection range: 16°C ~ 30°C.
• Operating the unit within the recommended temperature