•Vertical Automatic AirflowDirection Control and ManualAirflow Direction Control (5stages of adjustment).
•
Horizontal Automatic AirflowDirection Control and ManualAirflow Direction Control (5stages of adjustment).
FAN SPEED
TEMP
TIMER
ON
OFF
∧∨
SET
CANCEL
CLOCK
CHECK
RESET
Indoor Fan Speed Selection
•Low
•
•
•
•
•
AUTOFAN
Medium-MediumMedium+HighAutomatic Fan Speed
Room Temperature Setting
•Increase or decrease set temperature(16°C to 30°C)
Timer Operation Selection
•24-hour, OFF / ON Real Timer Setting.
Time / Timer Setting
•Hours and minutes setting.
Timer Operation Set / Cancel
•ON Timer and OFF Timer setting and
cancellation.
Clock Setting
•Current time setting.
Check Point
•Breakdown self diagnosis function.
Reset Point
• Clear memory data.
3
CS-XE9DKE CU-XE 9DKE / CS-XE12DKE CU- XE12DKE
2.2. INDOOR UNIT
AUTO
OFF / ON
Automatic Operation Switch
• Press for < 5s to operate Automatic operation
mode.
(Used when the remote control cannot be
used.)
• Press continuously for 5s or < 8s to operate
Test Run/Pump down. “Beep” sound will be
heard.
(Used when test running or servicing.)
• Press continuously for 8s or < 11s to operate
Forced Heating Operation. “Beep, beep”
sound will be heard.
• Press continuously for 11s or < 16s to change
different remote control setting (A↔B Mode),
or testify oxygen operation “Beep, beep, beep”
sound will be heard.
• Press continuously for 16s or < 21s to omit or
resume the remote control signal receiving
sound or H14 Abnormality Detection Mode.
Operation Indication Lamps (LED)
• POWER (Green) .....
• (Green).......
• ION (Green)...........
•QUIET (Orange).....
•TIMER (Orange).....
Lights up in operation,blinks in AutomaticOperation Mode judgingdeice, ON Timer samplingand Hot Start operation.
Lights up in Oxygen ModeOperation.
Lights up in Ionizer ModeOperation. Blinks in Ionizer
error.Lights up in Quiet Mode
Operation.Lights up in Timer Setting.Blinks in Self Diagnosis
Control.
Automatic and 5 Manual Indoor Fan
Speeds
Automatic and 5 Manual Vertical
Airflow Directions
Automatic and 5 Manual HorizontalAirflow Directions
Random Auto Restart Control
•Operation is restarted randomly after powerfailure at previous setting mode.
Delay ON Timer and OFF Timer
Microcomputer-controlled RoomTemperature Control
Breakdown Self Diagnosis Function
Low Pressure Control(Gas Leakeage Detection)
Indoor Power Relay Control
Deodorizing Control
Anti-Dew Formation Control
Anti Freezing Control
Five Operation Modes
•Heating, Cooling, Soft Dry, Fan and AutomaticMode.
Oxygen Operation
•To suppy oxygen enrich air.
Quiet Operation
•To provide quiet operation.
Ionizer Control
•Ionizer control for generate negative ion indischarge air.
Anti-Cold Draft Control
Hot Start
Intake Air Temperature Control
High Pressure Control
Deice Operation
4
2.3. OUTDOOR UNIT
Time Delay Safety Control
30 seconds Forced Operation
CS-XE9DKE CU-XE 9DKE / CS-XE12DKE CU- XE12DKE
Overload Protection
Total Running Current Control
Compressor Overheating
Prevention Control
IPM (Power Transistor)Overheating Protection Control
Inverter control, which equipped with a microcomputer in determining the most suitable operating modeastimepasses,
automatically adjusts output power for maximum comfort always. In order to achieve the suitable operatingmode,the
microcomputer maintains the set temperature by measuring the temperature of the environment and performingtemperature
shifting. The compressor at outdoor unit is operating following the frequency instructed by the microcomputeratindoorunitthat
judging the condition according to internal setting temperature and intake air temperature.
8.1.1. Internal Setting Temperature
Once the operation starts, remote control setting temperature will be taken as basevaluefortemperatureshiftingprocesses.
These shifting processes are depending on the air conditioner settings and the operationenvironment.Thefinalshiftedvalue
will be used as internal setting temperature and it is updated continuously whenevertheelectricalpowerissuppliedtotheunit.
When Freq. H is equalto20(XE9DK),27(XE12DK)forcooling,25(XE9DK),32(XE12DK)forheatingorabove,theComp.
may run at the freq.higherthanFcorFhuptomax.freq.operation.
Best AmenityControl
Every 90s(Cooling),120s(Heating)maintainsamezoneFreq.H+1untilFc,Fh.
Values of T1, T2, and T3 depend on remote control setting temperature, as shown in below table. After the adjustment of T1, T2
and T3 values, the operation mode for that particular environment and remote control setting is judged and performed, based on
the above operation mode chart, every 30 minutes.
The operation mode chart for this example is as shown in below figureandtheoperationmodetobeperformedwilldependon
indoor intake air temperature and outdoor air temperature at the timewhenthejudgmentismade.
Control at cooling/dry operation and auto fan speed setting.
No Deodorizing Control is performed during ON timer standby operation and during Anti-freezing control prevention.
ii. Operation
The odor status is arranged as below and it is shifted as follow.
* When COMP is ON1→2→3
(Shift to 4 when COMP is OFF)
* When COMP is OFF4→5→4
(Shift to 1 when COMP is ON)
* Start from 4 if the Thermostat is OFF during the start operation.
←→
5
8.1.8. OutdoorFanMotorOperation
6 pole induction,1speed780rpm(XE9DK),810rpm(XE12DK).
•
It startswhencompressorstartsoperationanditstops30secondsaftercompressorstopsoperation.
•
23
CS-XE9DKE CU-XE 9DKE / CS-XE12DKE CU- XE12DKE
8.1.9. Airflow Direction
1. There are two types of airflow, vertical airflow (directed by horizontal vane) and horizontal airflow (directed by vertical vanes).
2. Control of airflow direction can be automatic (angles of direction is determined by operation mode, heat exchanger temperature
and intake air temperature) and manual (angles of direction can be adjusted using remote control).
Vertical Airflow
Operation ModeAirflow DirectionVane Angle (°)
12345
HeatingAuto with Heat Exchanger17
Temperature58
7
Manual717334967
Cooling, Soft Dry and Fan, Ion, O
Mode Judgement in AutoAuto7
1. Automatic vertical airflow direction can be set using remote control; the vaneswingsupanddownwithintheanglesasstated
above. For heating mode operation, the angle of the vane depends ontheindoorheatexchangertemperatureasFigure1
below. When the air conditioner is stopped using remote control,thevanewillshifttocloseposition.
Auto7~37
2
Manual717253341
Manual717253341
2. Manual vertical airflow direction can be set using remotecontrol;theanglesofthevaneareasstatedaboveandthe
positions of the vane are as Figure 2 below. When theairconditionerisstoppedusingremotecontrol,thevanewillshiftto
close position.
2. Manual horizontal airflow direction can be set using remote control; the angles of the vane are as stated below and the
positions of the vane are as Figure 2 above.
Pattern12345
Airflow Direction
Patterns at Remote
Control
Vane Angle (°)905570110125
8.1.10. Quiet operation (Cooling Mode/Cooling area of Dry Mode)
A. Purpose
To provide quiet cooling operation compare to normal operation.
B. Control condition
a. Quiet operation start condition
• When “quiet” button at remote control is pressed.
Quiet LED illuminates.
b. Quiet operation stop condition
1. When one of the following conditions is satisfied,quietoperationstops:
a. Quiet button is pressed again.
b. Stop by OFF/ON switch.
c. Timer “off” activates.
d. When change mode to fanonlymode.
2. When quiet operation is stopped,operationisshiftedtonormaloperationwithprevioussetting.
3. When fan speed is changed,quietoperationisshiftedtoquietoperationofthenewfanspeed.
4. When operation modeischanged,quietoperationisshiftedtoquietoperationofthenewmode,exceptfanonlymode.
5. During quiet operation,iftimer“on”activates,quietoperationmaintains.
6. After off, whenonback,quietoperationisnotmemorised.
Delay ON timer can be set using remote control, the unit with timer set will start operate earlier than the setting time.Thisisto
provide a comfortable environment when reaching the set ON time.
Seventy minutes before the set time, indoor (at fan speed of Lo-) and outdoor fan motor start operate for 30 secondstodetermine
the indoor intake air temperature and outdoor air temperature in order to judge the operation starting time.
From the above judgment, the decided operation will start operate earlier than the set time as shownbelow.
8.1.12. Delay OFF Timer Control
Delay OFF timer can be set using remote control,theunitwithtimersetwillstopoperateatsettime.
8.1.13. Auto RestartControl
1. When the powersupplyiscutoffduringtheoperationofairconditioner,thecompressorwillre-operatewithinthreetofour
minutes (thereare10patternsbetween2minutes58secondsand3minutes52secondstobeselectedrandomly)afterpower
supply resumes.
2.Whentheswitchispressedbetween5to8seconds,theunitisforcedtooperate in Cooling Mode.
3.Whentheswitchispressedbetween8to11seconds,theunitisforced to operate in Heating Mode.
27
CS-XE9DKE CU-XE 9DKE / CS-XE12DKE CU- XE12DKE
4. When the switch is pressed between 11 to 16 seconds and together with the signal from remote control, the unit can be
changed to different controlling setting (A-B mode) or to testify oxygen operation.
5. When the switch is pressed between 16 to 21 seconds, either “H14” error detection selection mode or the remote controlsignal
receiving sound can be cancelled or turned on.
8.1.15. Indoor Power Relay Control
Power relay will turn on during operation or in progress of stopping operation. Although operation stops,thepowerrelaycontinues
on for three minutes.
However, during an instantaneous power failure (< 0.5s), power relay will turn off. Then, it will turnon2minutesafterpowerrecover
and the unit will operate as previous operation condition.
8.1.16. Ionizer Operation
Purpose
To provide fresh air effect to users by discharging minus ion to air.
Control Condition
a. Ionizer Only Operation.
1. When an air-conditionerunitisat“OFF”condition(standby)andanIONoperationbuttonatremotecontrolispressed.
Fan & ionizeron,IONLEDilluminates,butpowerLEDmaintainoff.(1→2)