Panasonic CS-W24EKR, CU-W24EKR Operating Instructions Manual

F565375
CS-W24EKR CU-W24EKR
Manufactured by:
Panasonic HA Air-Conditioning (M) Sdn. Bhd.
Lot 2, Persiaran Tengku Ampuan, Section 21, Shah Alam Industrial Site, 40300 Shah Alam, Selangor, Malaysia.
Operating Instructions
ENGLISH Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
© 2006 Panasonic HA Air-Conditioning (M) Sdn Bhd (11969-T). All rights reserved. Unauthorized copying and distribution is a violation of law.
2
This symbol denotes
an action that is
PROHIBITED.
These symbols denote
actions that are
COMPULSORY.
Definition
Warning
Caution
To prevent personal injury, injury to others, or property damage, please observe the following.
Incorrect operation due to failure to follow instructions may cause harm or damage, the seriousness of which is classifi ed as below:
The instructions to be followed are classifi ed by the following symbols:
Caution
Thank you for purchasing Panasonic Air Conditioner
• Aerate the room regularly.
• After long periods of use, make sure the installation rack is not damaged.
• Insert the power plug properly.
• Use the specifi ed supply cord.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualifi ed persons in order to avoid a hazard.
• Remove the batteries if the unit is not going to be used for a long period of time.
• New batteries of the same type must be inserted following the polarity stated to prevent malfunction of the remote control.
• In case of emergency or abnormal conditions (burning, unusual odour, etc), turn off the power supply and unplug.
Warning
During Installation
During Installation
• Do not share the same power outlet with other equipment.
• Do not modify power cords.
• Do not use extension cords.
• Do not operate with wet hands.
• Do not operate or stop the unit by inserting
or pulling out the power plug.
• Do not insert your fi ngers or other objects into the indoor or outdoor unit.
• Do not attempt to repair the unit by yourself.
• Do not use rechargeable (Ni-Cd) batteries.
• Do not allow infants and small children to play with remote control to prevent them from accidentally swallowing the batteries.
• Do not install, remove and reinstall the unit by yourself; improper installation will cause leakage, electric shock or fi re. Please consult an authorized dealer or specialist for the installation work.
• This equipment must be earthed and installed with ELCB. It may cause electrical shock or fi re in case of malfunction.
During Operation
During Operation
• Switch off the power supply and unplug before cleaning or servicing.
• Turn off the power supply and unplug if the unit is not used for a long period of time.
• This air conditioner is equipped with a built-in surge protective device. However, in order to further protect your air conditioner from being damaged by abnormally strong lightning activity, you may want to disconnect it from the power supply.
• Do not pull the cord to disconnect the plug.
• Do not wash the unit with water, benzene, thinner or scouring powder.
• Do not use for other purposes such as preservation of food.
• Do not use any combustible equipment in front of the airfl ow outlet.
• Do not sit or place anything on the indoor or outdoor unit.
• Do not expose directly to cold air for a long period.
• Ensure that the drainage pipe is connected properly. Otherwise, leakage may occur.
• Do not install the unit in a potentially explosive atmosphere.
During Installation
During Installation
During Operation
During Operation
SAFETY PRECAUTIONS
SAFETY PRECAUTIONS ...................................................................................................................... 2
REGULATORY INFORMATION ............................................................................................................ 3
PRODUCT OVERVIEW ........................................................................................................................ 4
AUTO, HEAT, COOL, DRY .................................................................................................................... 5
FAN SPEED, AIR SWING ..................................................................................................................... 6
POWERFUL, QUIET, ION ..................................................................................................................... 7
TIMER ................................................................................................................................................... 8
CARE & CLEANING .............................................................................................................................. 9
TABLE OF CONTENT
This sign warns of death
or serious injury.
This sign warns of injury
or damage to property.
3
ENGLISH
Replacement or installation of power plugs shall be performed by authorized/qualifi ed personnel only.The wires in this mains lead are coloured in accordance with the following code:
Wiring colour may vary depending on a country wiring code’s standard.
Operation Condition
REGULATORY INFORMATION
Battery Disposal
The batteries must be recycled or disposed of properly.
“Instructions for end-user” for air conditioners:
Information on Disposal in other countries outside the European Union
This symbol is only valid in the European Union. If you wish to discard this product, please contact your installer, dealer or local authority and ask for the correct method of disposal.
EEnvironmental Requirements
nvironmental Requirements
End-of-Life Disposal
End-of-Life Disposal
Note:
The illustrations in this manual are for explanation purposes only and may differ from the actual unit. It is subjected to change without notice for future improvement.
The appliance is not intended for use by young children or the infi rm person without supervision. Young children should be supervised to ensure that they do not play with the appliance.
Use this air conditioner under the following temperature range.
Temperature (°C)
Indoor
*DBT *WBT
COOLING
Maximum 32 23
Minimum 16 11
HEATING
Maximum 30
Minimum 16
Temperature (°C)
Outdoor
*DBT *WBT
COOLING
Maximum 43 26
Minimum 16 11
HEATING
Maximum 24 18
Minimum -5 -6
*DBT: Dry bulb temperature *WBT: Wet bulb temperature
4
MODE
AIR
SWIN
G
FAN S PEED
QUIET
POWERFUL
1
2
3
TIMER
ON
OFF
CANCE
L
SET
RESET
CLOCK
OFF/ON
TEMP
COOL
AUTO
AU
T
T
O
AUTO FAN
LCD display
Off/On
Fan speed selection
Memory reset
Clock setting
Temperature setting
Powerful operation
Operation mode
Quiet operation
Timer setting
Ion operation
Airflow direction adjustment
Transmitter
About
Remote Control Preparation
PRODUCT OVERVIEW
Air inlet (rear)
Air outlet
• Make sure it is not obstructed.
• Maximum distances: 10m.
• Certain fluorescent lights may interfere with signal transmission. Please consult your nearest dealer.
Remote Control Signal
Auto OFF/ON Button
5. Press again.
6. Close the cover.
• Timer operation will be based on current time set.
• The batteries can be used for approximately 1 year.
3. Press CLOCK.
Air inlet (side)
Indoor Unit
Indoor Unit
Outdoor Unit
Outdoor Unit
Remote Control
Remote Control
1. Press and pull out.
2. Insert AAA or R03 batteries.
4. Press to set time.
Q
U
IET
PO
WERFUL
ION
SUPER
ALLERU-BUSTER
TIM
ERPOW
E
R
Air intake
Airflow direction louver
Ionizer
Air filter
Front panel
Supersonic air purifying device
Auto OFF/ON button
Receiver
Discharged air
Do not touch during operation
Indicator
Action Mode
Press once Automatic
Press and hold until you hear one beep, then release.
Cooling
• To turn off, press the AUTO OFF/ON button again.
• To switch the remote control signal receiving sound off or on.
1. Press until a single beep sound is
heard and release.
2. Press again until a double beep
sound is heard and release.
3. Press to switch the sound on or
off.
(Long beep - OFF; short beep
- ON)
Loading...