Panasonic CS-MKS9NB4U Data Sheet

Split System Submittal Data
Indoor: CS-MKS9NB4U Multi System Indoor Units - Ceiling Recessed
General Data
Power (V/P/Hz) 208 - 230/1/60
Circuit Ampacity (A) N/A Fuse Size, Max.(A) 15 Running Amps (A) COOL .11 / .1 Power Input (W) COOL 15 / 16
Indoor Unit Cool/Heat
Fan type Turbo Dia & Length (in.) - No. Speeds D12-5/8 L5-3/4 -1 No. Speeds 3 & Auto No. Poles (RPM, High) 8 - 440 No. Motors (W) 1-(23) CFM (HI) 221 Operation Sound (HI/Med/Lo) 33/32/31
Coil Type Aluminum Plate Fin & Copper
Tube
Fin Type - Pipe Type Slit Plate - Inner Rifled Rows - F.P.I. 2 - 18.1 Face Area (sq.ft.) 2.94 Tube Size (in) N/A Drain Connection Size 3/4
Refrigerant R410A
Line Size (in. O.D. Discharge) 1/4” (Flare) Line Size (in. O.D. Suction) 3/8” (Flare)
Approval: Date: Construction: Unit#: Drawing#:
Performance Data @ ARI Standard Conditions (230V)
Cooling
Total Capacity (BTU/H) 9000 Moisture Removal (HI, Pint/H) 3.4
Features
Controls Microprocessor Remote Control LCD Wireless Type, Built-in Temp
Sensor Temperature Control IC Thermostat Timer 24 Hr. Program, 1 Hr. Off Night Setback Built-In Air Louver Automatic Power Failure Automatic Restart Built-In Self-Diagnosis Built-In Quiet Operation Built-In Air Filter Washable, Anti-Mold
Dimensions (HxWxD)
Indoor Unit (Crated) (in.) 11-13/32 x 24-13/16 x 28-1/8 Indoor Unit (Uncrated) (in.) 12-5/16 x 24-19/32 x 24-19/32
Weight (lbs.)
Net 35.3 Shipping 41.9
Shipping Volume (cu.ft.) 4.59
Option
Refrigerant Line Set Available Fresh Air Intake Knock-out Airduct Extension N/A Condensate Drain Pump Standard Hard Wired Remote Controller Available Non-Removeable Remo-con
Bracket
Operating Range
Cooling (Max) 95F DB/71F WB 115F DB Cooling (Min) 67F DB/57F WB 14F DB
Indoor Air Intake Temp
Available
Outdoor Air Intake Temp
Indoor Dimensions
Indoor Unit CS-KS12NB41 & CZ-18BT1U
CS-KS18NB4UW & CZ-18BT1U
AA
Air intake
1
Discharge outlet
2
Refrigerant tubing
3
Refrigerant tubing
4
Drain tube connection port VP20 (outer dia. 1")
5
Power supply port
6 7
Suspension bolt hole (4 - 1/2" x 1-1/8" hole)
Fresh air intake duct connection port (dia. 3-7/8")
8
(liquid tube)
(gas tube)
dia. 1/2"
dia.
1/4" (flared)
(flared)
23-5/8 (600)
Ceiling opening dimensions
21-1/32
Suspension bolt pitch
7
12-7/8
(534)
Center of panel
23-5/8 (600)
21-1/32 (534)
12-7/16
Suspension bolt pitch
Ceiling opening dimensions
4-29/32
A View
7-11/16
8
22-5/8 (575)
3-5/8
7-23/32
1-27/32 1-3/32
Unit : inch (mm)
2-3/32
2-3/4 1-9/32
5-9/16
22-5/8 (575)
2-3/32
6-5/16 6-11/16
1-25/32
4-19/32
1-25/32
Less than 31/32 Less than 31/32
3
6
24-19/32 (625)
14-3/32 (358)
5
8-15/32
11-5/32 (283)
1-3/16 (30)
2
2
25/32
The length of the suspension bolts should be selected so that there is a gap of 1-3/16" or
2 1
2
the ceiling (21/32" or more below the lower surface of the main unit), as shown in the figure at right. If the suspension bolts is too long, it will contact
13-5/32 (334)
24-19/32 (625)
the ceiling panel and the unit cannot be installed.
3-1/8
21/32
1-3/16
Panasonic North America Air Conditioning Division
1690 Roberts Blvd., NW, Suite 110 Kennesaw, GA 30144 us.panasonic.com/aircon