Order No. MAC0502033C1
A i r C ondit ioner
CS-C9DKU CU-C9DKU
CS-C12D KU CU-C12D KU
CONTENTS
Page Page
1 Featur es 2
2 Funct ions
3 Produ ct Specif ication s
3.1. CS-C9 DKU CU-C9 DKU
3.2. CS-C1 2DKU CU-C1 2DKU
4 Dimen sions
4.1. Indoor Unit & Remot e Contro l
4.2. Outdo or Unit
5 Refrig eratio n Cycle Diagra m
6 Block Diagra m
7 Wiring Diagra m
8 Opera tion Detail s
8.1. Coolin g Opera tion
8.2. Soft D r y Opera tion
8.3. Automatic Operation
8.4. Operation Control
10
10
11
12
13
14
15
15
16
17
18
3
6
6
8
8.5. Indoor Fan Speed Contro l 21
8.6. Outdo or Fan Speed Contro l
8.7. Vertica l Airflow Directi on Contro l
8.8. Horizo ntal Airflow Directi on Contro l
8.9. Power ful Opera tion
8.10. Quiet Opera tion
8.11. Timer Contro l
8.12. Rando m Auto Restar t Contro l
8.13. Remot e Contro l Signal Receiv ing Sound
8.14. Econo m y Mode Opera tion
9 Opera ting Instru ctions
10 Install ation Instru ctions
10.1. Safety Precau tions
10.2. Attach ed access ories
10.3. Select the best location
10.4. Indoor/Outdoor Unit Installation Diagram
© 2005 Panasonic HA Air-Conditioning (M) Sdn Bhd
(11969-T). All rights reserved. Unauthorized copying
and distribution is a violation of law.
23
23
24
24
25
26
26
26
27
28
34
34
36
36
36
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
10.5. Indoor unit 37
10.6. Outdoor unit
11 2-way, 3-way Valve
11.1. Evacuation of Installation
11.2. Pumping down
11.3. Evacuation of Re-installation
11.4. Balanc e refrige rant of the 2-way, 3-way valves
11.5. Evacu ation
11.6. Gas chargi ng
12 Servic ing Inform ation
12.1. Distinc tion of Lead Free (PbF) Printed Circuit Board
12.2. Indoor Electro nic Contro ller Remov al Proced ures
12.3. Indoor Fan Motor and Cross Flow Fan Remov al
Proced ures
12.4. Auto OFF/O N Button
12.5. Remot e Contro l Reset
1 Featur es
• High Efficiency
• Compact Design
• W ider range of horizontal discharge air.
• A i r Filter with function to reduce dust and smoke.
13 Troubleshooting Guide 57
40
45
46
47
48
49
50
51
52
52
52
54
55
56
13.1. Refrigeration cycle system
13.2. Relationship between the condition of the air conditioner
and pressure and electric current
13.3. Diagnosis methods of a malfunction of a compressor
14 Technical Data
14.1. Therm ostat charac teristic s
14.2. Opera tion charac teristic s
15 Explo ded View (Indoo r Unit)
16 Repla cemen t Parts List (Indoo r Unit)
17 Explo ded View (Outdoor Unit)
18 Repla cemen t Parts List (Outdoor Unit)
19 Electr onic Circui t Diagra m
19.1. Indoor Unit
19.2. Remot e Contro l
19.3. Print Pattern Indoor Unit Printed Circuit Board
• Q uality Improvement
− Random auto restart after power failure for safety restart
operation.
− G a s leakage protection.
− Prevent Compressor reverse cycle.
− Inner protector to protect Compressor.
− Noise prevention during soft d r y operation.
− Blue Coated Condenser for high resistance to corrosion.
57
58
58
59
59
60
64
65
66
67
68
68
74
75
• A utomatic air swing and manual adjusted by Remote
Control for vertical airflow.
• Long installation piping.
− CS/CU-C9DKU, long piping up to 33ft.
− CS/CU-C12DKU , long piping up to 49ft.
• O peration Improvement
− Q uiet mode to provide quiet operation.
− Powerful mode to reach the desired room temperature
quickly.
− 2 4-hour timer setting.
• S erviceability Improvement
− Removable and washable Front Panel.
2
2 Functions
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
ı
3
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
4
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
5
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
3 Product Specifications
3.1. CS-C9DKU CU-C9DKU
Unit Indoor unit Outdoor unit
Power Source (Phase, Voltage, Cycle) ø, V, Hz Single, 115, 60
Coolin g Capac ity k W (BTU/h ) 2.58 (8,800 )
Moistu re Remov al l/h (Pint/h ) 1.0 (2.1)
Airflow Metho d OUTLE T
INTAK E
Air Volum e Lo m 3 /min (cfm) 4.7 (164) - 4.7 (164) —
Me m 3 /min (cfm) 5.7 (202) - 5.7 (202) —
Hi m 3 /min (cfm) 7.2 (250) - 7.2 (250) 33.8 (1,190 )
SHi m 3 /min (cfm) 7.8 (274) - 7.8 (274) —
Noise Level dB (A) High 36 - 36, Low 26 - 2 6 High 49
Power level dB High 49 - 3 9 High 62
Electri cal Data Input Power W 790
Runnin g Curren t A 7.2
EER W / W (BTU/h W ) 3.27 (11.10 )
Startin g Curren t A 42.0
Piping Conne ction Port
(Flare piping)
Pipe Size
(Flare piping)
Drain
Hose
Power Cord Length m — —
Dimen sions Height inch (mm) 11 - 1/32 (280) 21 - 1/4 (540)
Net Weigh t lb (kg) 20 (9.0) 64 (29)
Compr essor Descri ption — Rotary (1 cylinde r)
Fan Motor Descri ption Cross- flow Fan Propel ler Fan
Heat Excha nger Descri ption Evapo rator Conde nser
Refrigerant Control Device — Capillary Tube
Refrigeration Oil (cm3) — SUNISO 4GDID or ATMOS M60
Refrigerant (R-22) g (oz) — 680 (24.0)
Inner diame ter inch (mm) 20/32 (16) —
Length inch (mm) 25- 19/32 (650) —
Numbe r o f core- wire — —
Width inch (mm) 31 - 15/32 (799) 30 - 23/32 (780)
Depth inch (mm) 7 - 7/32 (183) 11 - 3/8 (289)
Motor Type — Induct ion (2- poles)
Rated Outpu t W — 600
Materi al ASG32 K1 PP Resin
Type Induct ion (4- poles) Induct ion (6- poles)
Input W 60.61 85.8
Rated Outpu t W 15 30
Fan Speed Low rpm 750 - 750 —
Mediu m rpm 920 - 920 —
High rpm 1,160 - 1,160 845
SuperH igh rpm 1,250 - 1,250 —
Tube materi al Coppe r Coppe r
Fin materi al Alumin ium (Pre Coat) Alumin ium (Blue Coat)
F i n Type Slit Fin Louve r Fin
Row / Stage (Plate fin configu ration, forced draft)
FPI 21 16
Size (W × H × L) inch (mm) 24-1/32 ×12-13/32 × 1
inch
inch
inch
inch
SIDE VIEW T O P VIEW
G ; Half Union 3/8”
L ; Half Union 1/4”
G ; (gas side) 3/8”
L ; (liquid side) 1/4”
2× 1 5 1× 2 0
(610 × 315 × 25.4)
G ; 3-way valve 3/8”
L ; 2-way valve 1/4”
G ; (gas side) 3/8”
L ; (liquid side) 1/4”
rolling piston type
33-4/32 × 20-3/8 × 28/32
(841 × 508 × 22)
or ATMOS 56
6
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
Unit Indoor unit Outdoor unit
Thermostat Electrical —
Protection Device — 2 Stage Overload Protector
Capillary Tube Length inch (mm) — 26-18/32 (675)
Flow Rate l/min — 13.0
Inner Diameter inch (mm) — 20/32 (1.6)
Air Filter Material
Style
Capac i t y Contro l Capilla r y Tube
Compr essor Capac itor µF, VAC — 35 µF, 370VA C
Fan Motor Capac itor µF, VAC 5.0 µF, 230VA C 8.0 µF, 230VA C
P.P.
Honeycomb
—
Note:
• Specifications are subjected to change without prior notice for further improvement.
7
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
3.2. CS-C12DKU CU-C12DKU
Unit Indoor unit Outdoor unit
Power Source (Phase, Voltage, Cycle) ø, V, Hz Single, 115, 60
Cooling Capacity kW (BTU/h) 3.60 (12,30 0)
Moisture Removal l/h (Pint/h) 1.6 (3.4)
Airflow Metho d OUTLE T
INTAK E
Air Volum e Lo m 3 /min (cfm) 5.6 (199) - 5.6 (199) —
Me m 3 /min (cfm) 6.8 (238) - 6.8 (238) —
Hi m 3 /min (cfm) 8.0 (280) - 8.0 (280) 31.1(1 ,100)
SHi m 3 /min (cfm) 8.2 (289) - 8.2 (289) —
Noise Level dB (A) High 39 - 39, Low 29 - 2 9 High 49
Power level dB High 52 - 4 2 High 62
Electri cal Data Input Power kW 1.16
Runnin g Curren t A 10.3
EER W / W (BTU/h W ) 3.10 (10.60 )
Startin g Curren t A 57.0
Piping Conne ction Port
(Flare piping)
Pipe Size
(Flare piping)
Drain
Hose
Power Cord Length m — —
Dimen sions Height inch (mm) 11 - 1/32 (280) 21 - 1/4 (540)
Net Weigh t lb (kg) 20 (9.0) 73 (33)
Compr essor Descri ption — Rotary (1 cylinde r) rolling piston
Fan Motor Descri ption Cross- flow Fan Propel ler Fan
Heat Excha nger Descri ption Evapo rator Conde nser
Refrige rant Contro l Device — Capilla r y Tube
Refrigeration Oil (cm3) — ATMOS M60 or SUNISO 4GDID
Refrigerant (R-22) g (oz) — 760 (26.8)
Thermostat Electrical —
Protection Device — 2 Stage Overload Protector
Inner diame ter inch (mm) 20 / 3 2 (16) —
Length inch (mm) 25- 19/32 (650) —
Numbe r o f core- wire — —
Width inch (mm) 31 - 15/32 (799) 30 - 23/32 (780)
Depth inch (mm) 7 - 7/32 (183) 11 - 3/8 (289)
Motor Type — Induct ion (2- poles)
Rated Outpu t W — 850
Materi al ASG32 K1 PP Resin
Motor Type Induct ion (4- poles) Induct ion (6- poles)
Input W 60.61 66.0 - 75.0
Rated Outpu t W 15 31
Fan Speed Low rpm 900 - 900 —
Mediu m rpm 1,080 - 1,080 —
High rpm 1,280 - 1,280 820 - 820
SuperH igh rpm 1,310 - 1,310 —
Tube materi al Coppe r Coppe r
Fin materi al Alumin ium (Pre Coat) Alumin ium (Blue Coat)
F i n Type Slit Fin Louve r Fin
Row / Stage (Plate fin configu ration, forced draft)
FPI 21 16
Size ( W × H × L ) inch (mm) 24- 1/32 × 12-13/ 32 × 1
inch
inch
inch
inch
SIDE VIEW T O P VIEW
G ; Half Union 1/2”
L ; Half Union 1/4”
G ; (gas side) 1/2”
L ; (liquid side) 1/4”
2× 1 5 2× 2 4
(610 × 315 × 25.4)
G ; 3-way valve 1/2”
L ; 2-way valve 1/4”
G ; (gas side) 1/2”
L ; (liquid side) 1/4”
29- 10/32; 28-15/ 32 × 19-27/ 32 ×
744.2; 723.5 × 504 × 25.4
or ATMOS M56
type
1
8
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
Unit Indoor unit Outdoor unit
Capillary Tube Length inch (mm) — 16-23/32 (425)
Flow Rate l/min — 18.0
Inner Diameter inch (mm) — 2/32 (1.7)
Air Filter Material
Style
Capacity Control Capillary Tube
Compressor Capacitor µF, VAC — 50 µF, 370VAC
Fan Motor Capac itor µF, VAC 5.0 µF, 230VA C 8.0 µF, 230VA C
P.P.
Honeycomb
—
Note:
• Specifications are subjected to change without prior notice for further improvement.
9
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
4 Dimensions
4.1. Indoor Unit & Remote Control
10
4.2. Outdoor Unit
CU-C9DKU
CU-C12DKU
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
11
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
5 Refrigeration Cycle Diagram
CS-C9DKU CU-C9DKU
CS-C12DKU CU-C12DKU
12
6 Block Diagram
CS-C9DKU CU-C9DKU
CS-C12DKU CU-C12DKU
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
13
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
7 Wiring Diagram
CS-C9DKU CU-C9DKU
CS-C12DKU CU-C12DKU
REMARKS
B : BLUE
BR : BROWN
BL : BLACK
GRY : GRAY
O : ORAN GE
P : PINK
R : RED
W : WHITE
Y/G : YELLO W/GR E E N
Power Supply Cord
Resistance of Indoor Fan Motor Windings
MODE L CS- C9DKU
CS- C12DK U
CONN ECTIO N CWA9 21143
BLUE- YELLO W 82.4 Ω
YELLO W - RED 103.4 Ω
Note: Resist ance at 68°F of ambie nt tempe rature.
Resistance of Outdoor Fan Motor Windings
MODE L CU- C9DKU
CONN ECTIO N CWA9 51244
BLUE- YELLO W 61.2 Ω
YELLO W - RED 53.4 Ω
Note: Resist ance at 78.8°F of ambie nt tempe rature.
CU- C12DK U
Resistance of Compressor Windings
MODE L CU- C9DKU CU- C12DK U
CONN ECTIO N 2R135 126A 2P19S 126C- 1A
C-R 0.938 Ω 0.613 Ω
C-S 2.611 Ω 2.106 Ω
Note: Resist ance at 77°F/6 8°F of ambie nt tempe rature.
14
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
8 Operation Details
8.1. Cooling Operation
• Cooling operation can be set using remote control.
• T his operation is applied to cool down the room temperature reaches the setting temperature set on the remote control.
• T h e remote control setting temperature, which takes the reading of intake air temperature sensor, can be adjusted from 60.8°F
to 86°F.
• During cooling operation, the compressor will stop running and restart as shown in below figure.
8.1.1. Cooling Operation Time Diagram
15
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
8.2. Soft Dry Operation
• Soft Dry operation can be set using remote control.
• Soft Dry operation is applied to dehumidify and to perform a gentle cooling to the room.
• This operation starts when the intake air temperature sensor reaches the setting temperature on the remote control.
• W hen operation begins, Soft Dry will be switched “ON” for a maximum 10 minutes, then Soft Dry operation will be turned “OFF”
for a minimum 6 minutes. After that, the Soft Dry operation will be “ON” and “OFF” based on the setting temperature as shown
in below figure.
• However after 3 minutes of compressor off, during Soft Dry “OFF” (within 6 minutes Soft Dry restart control), the indoor unit will
start to operate at normal Cooling mode if the intake temperature is higher than Cooling “ON” point.
8.2.1. Soft Dry Operation Time Diagram
16
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
8.3. Automatic Operation
• Automatic operation can be set using remote control.
• This operation starts to operate with indoor fan at SLo speed for 20 seconds to judge the intake air temperature.
• After judged the temperature, the operation mode is determined by referring to the below standard.
• T hen, the unit start to operate at determined operation mode, until it is switched off using remote control, with the setting
temperature as shown in below table.
• T h e setting temperature for all the operations can be changed one level up or one level down from the standard temperature
as shown in below table b y pressing on the temperature up or temperature down button at remote control.
• T h e operation mode judging temperature and standard setting temperature can be increased b y 3.6°F permanently, b y open
the circuit of JX1 at indoor electronic controller.
17
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
8.4. Operation Control
8.4.1. Restart Control (Time Delay Safety Control)
• When the thermo-off temperature (temperature which compressor stops to operate) is reached during:-
− Cooling/Heating operation - the compressor stops for 3 minutes (minimum) before resume operation.
− Soft D r y operation - the compressor stops for 6 minutes (minimum) before resume operation.
• I f the operation is stopped b y the remote control, the compressor will not turn on within 3 minutes from the moment operation
stop, although the unit is turn on again within the period.
• T his phenomenon is to balance the pressure inside the refrigerant cycle.
8.4.2. 7 Minutes Time Save Control
• T h e compressor will start automatically if it has stopped for 7 minutes and the intake air temperature falls between the
compressor ON temperature (A) and compressor OFF temperature (B) during the period.
• T his phenomenon is to reduce the built up humidity inside a room.
8.4.3. 60 Seconds Forced Operation
• O nce the air conditioner is turned on, the compressor will not stop within 60 seconds in a normal operation although the intake
air temperature has reached the thermo-off temperature. However, force stop b y pressing the OFF/ON operation button at the
remote control is permitted.
• T h e reason for the compressor to force operate at minimum 60 seconds is to allow the refrigerant oil run in a full cycle and
return back to the outdoor unit.
8.4.4. Starting Current Control
• W hen the compressor, outdoor fan motor and indoor fan motor are simultaneousl y started, the indoor fan motor will start to
operate at 1.6 second later.
• T h e reason of the difference is to reduce the starting current flow.
18
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
8.4.5. Anti-Freezing Control
• If the temperature of the indoor heat exchanger falls below 35.6°F continuously for 4 minutes or more, the compressor turns off.
The fan speed setting remains the same.
• This phenomenon is to protect the indoor heat exchanger from freezing and to prevent higher volume of refrigerant in liquid form
returning to the compressor.
• Compressor will restart again when the indoor heat exchanger temperature rises to 50°F (Recovery).
• Restart control (Time Delay Safety Control) will be applied in this Control if the recovery time is too short.
8.4.6. Compressor Reverse Rotation Protection Control
• If the compressor is operating continuously for 5 minutes or longer and the temperature difference between intake air and
indoor heat exchanger is 4.5°F or less for continuous 2 minutes, compressor will stop and restart automatically.
• T ime Delay Safety Control is activated before the compressor restart.
s T = Intake air temperature - Indoor heat exchanger temperature
• T his is to prevent compressor from rotate reversely when there is an instantaneous power failure.
8.4.7. Anti-Dew Formation Control
• Purpose is to prevent d e w formation on indoor unit discharge area.
• W hen room temperature is constant (±1.8°F) the following condition occur for 30 minutes continuously, anti- dew formation will
activate:
- Indoor intake temperature is more than 75.2°F and less than 86°F.
- Remote Control setting temperature is less than 77°F
- Compressor is on.
- Cooling Operation Mode.
- Indoor fan motor operate at L o w fan speed or QLo.
19
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
• Anti-Dew Formation is control by:-
• Increasing Air Flow Volume
1. Lo fan speed.
Lo fan speed is changed to Lo+ after 30 min to prevent dew formation.
2. QLo fan speed.
Dew formation m a y occur at QLo cool, therefore QLo cool is operated only 1hr 30min (1 hr QLo, 30 min QLo + 8 0 rpm). After
that, it operates at QLo + 160 rpm (However Quiet LED remains on).
• Narrowing
1. Vertical Airflow Direction
During Anti-Dew condensation prevention, Airflow Direction Auto-control angle from 0° - 32° to 20° - 30° under cooling and
Soft D r y operation mode.
20
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
During Anti-Dew condensation prevention, Airflow Direction Manual Control angle change from 10°, 15°, 20°, 26°, 32° to
22°, 24°, 26°, 28°, 30°.
8.5. Indoor Fan Speed Control
• Indoor Fan Speed can be set using remote control.
8.5.1. Fan Speed Rotation Chart
Speed Fan Speed (rpm)
CS- C9DKU CS- C12DK U
SH i 1250 1310
Hi 1160 1280
Me 920 1080
HL o 840 960
CL o 750 900
Lo- 750 850
SL o 710 820
SS Lo - -
QSH i - -
QH i 1060 1180
QM e 820 980
QH Lo - -
QL o 650 800
21
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
8.5.2. Automatic Fan Speed Control
• When set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the table.
− Fan speed rotates in the range of Hi and Me.
− Deodorizing Control will be activated.
• Auto Fan Speed during cooling operation:
1. Indoor fan will rotate alternately between off and on as shown in below diagram.
2. At the beginning of each compressor start operation, indoor fan will increase fan speed gradually for deodorizing purpose.
3. For the first time the compressor operate, indoor fan will be switched to Hi fan speed from Lo- after 70 seconds from the
start of compressor. This cause the room temperature to achieve the setting temperature quickly.
4. During compressor stop, indoor fan will operate at Lo for the beginning 20 seconds to prevent higher volume of refrigerant
in liquid form returning to the compressor.
5. After the compressor at turn off condition for 3 minutes, indoor fan will start to operate at Lo- to circulate the air in the room.
This is to obtain the actual reading of the intake air temperature.
6. For the resume of compressor operation, indoor fan will operate at Me fan speed to provide comfort and lesser noise
environment, after 70 seconds from the restart of compressor.
22
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
• Auto Fan Speed during Soft Dry operation:
1. Indoor fan will rotate alternately between off and Lo-.
2. At the beginning of each compressor start operation, indoor fan will increase fan speed gradually for deodorizing purpose.
3. When compressor at turn off condition for 6 minutes, indoor fan will start fan speed at Lo- to circulate the air in the room.
This is to obtain the actual reading of intake air temperature.
8.5.3. Manual Fan Speed Control
• Manual fan speed adjustment can be carried out b y using the Fan Speed selection button at the remote control.
• T here are 3 types of fan speed settings: Lo, Me, Hi.
8.6. Outdoor Fan Speed Control
• T here is only one speed for outdoor fan motor.
• W hen the air conditioner is turned on, the compressor and the outdoor fan will operate simultaneousl y .
• L ikewise, both compressor and outdoor fan will stop at the same time if the unit is turned off.
8.7. Vertical Airflow Direction Control
8.7.1. Auto Control
• W hen the vertical airflow direction is set to Auto using the
remote control, the louver swings up and down as shown in
the diagram.
• W hen stop operation using the remote control, the
discharge vent is reset, and stop at the closing position.
• During Cooling operation or Soft D r y operation, indoor fan
motor m a y stop to rotate at certain periods. At that
condition, the louver will stop swinging and rest at the upper
limit.
8.7.2. Manual Control
• W hen the vertical airflow direction is set to Manual using the
remote control, the automatic airflow is released and the
airflow direction louver move up and down in the range
shown in the diagram.
• T h e louver can be adjusted b y pressing the button to the
desired louver position.
• When stop operation using the remote control, the
discharge vent is reset, and stop at the closing position.
23
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
8.8. Horizontal Airflow Direction Control
• The horizontal airflow direction louvers can be adjusted manually by hand.
8.9. Powerful Operation
• T h e Powerful operation is to achieve the setting temperature quickly.
• W hen Powerful operation is set, the setting temperature will be automatically decreased 5.4°F internally against the present
setting temperature (Lower temperature limit: 60.8°F).
• T his operation automatically will be running under SHi Fan Speed (Cooling), Lo- Fan Speed (Soft Dry).
• V ertical Airflow Direction:-
- I n “Manual” setting, the vane will automatically shift down 10° lower than previous.
- I n “Auto” setting, the vane will automatically swing up and down. However the lower limit will be shifted 10° downward.
• P owerful Mode will operate for 15 minutes only and operation will shift back to previous setting mode.
• P owerful operation stops when:-
- Powerful mode button is pressed again.
- Stopped b y OFF/ON operation button.
- Timer OFF activates.
- Quiet mode button is pressed.
- Operation mode button is changed.
- Economy mode button is pressed.
24