Panasonic CS-C18JKV, CU-C18JKV, CS-C24JKV, CU-C24JKV Operating Instructions Manual

Operating Instructions
Air Conditioner
Indoor Unit Outdoor Unit
CS-C18JKV CU-C18JKV CS-C24JKV CU-C24JKV
F566341
ENGLISH
2 ~ 7
2 ~ 7
Before operating the unit, read these
Before operating the unit, read these
operating instructions thoroughly and
operating instructions thoroughly and
keep them for future reference.
keep them for future reference.
ESPAÑOL
8 ~ 13
8 ~ 13 Antes de utilizar la unidad, sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como futuro elemento de consulta.
PORTUGUÊS 14 ~ 19 Antes de ligar a unidade, leia cuidadosamente este manual de utilização e guarde-o para futura referência.
QUICK GUIDE
QUICK GUIDE
GUÍA RÁPIDA
GUÍA RÁPIDA
GUΙA RÁPIDO
GUΙA RÁPIDO
© Panasonic HA Air-Conditioning (M) Sdn. Bhd. 2008. Unauthorized copying and distribution is a violation of law.
2
SAFETY PRECAUTIONS SAFETY PRECAUTIONS
Remote Control
• Do not use rechargeable (Ni-Cd) batteries.
• Do not allow infants and small children to play with the remote control to prevent them from accidentally swallowing the batteries.
• Remove the batteries if the unit is not going to be used for a long period of time.
• New batteries of the same type must be inserted following the polarity stated to prevent malfunction of the remote control.
Outdoor Unit
• Do not sit or step on the unit, you may fall down accidentally.
• Do not touch the sharp aluminium n, sharp parts may cause injury.
• After long periods of use, make sure the installation rack is not damaged.
Power Supply
• Do not pull the cord to disconnect the plug.
• Switch off the power supply and unplug before cleaning or servicing.
• Turn off the power supply and unplug if the unit is not used for a long period of time.
• This air conditioner is equipped with a built-in surge protective device. However, in order to further protect your air conditioner from being damaged by abnormally strong lightning activity, you may want to disconnect it from the power supply. Do not touch the air conditioner during lightning, it may cause electric shock.
Air inlet
Air inlet
Air
Air
outlet
outlet
Air outlet
Air inlet
Air inlet
Power Supply
• Do not share the same power outlet with other equipment.
• Do not modify power cords.
• Do not use extension cords.
• Do not operate with wet hands.
• Do not operate or stop the unit by inserting or pulling out the power plug.
• Insert the power plug properly.
• Use the specifi ed supply cord.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualifi ed persons in order to avoid a hazard.
• Dust on the electric power plug should be periodically wiped with a dry cloth.
• This equipment must be earthed and strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD). Otherwise, it may cause electrical shock or fi re in case of malfunction.
• In case of emergency or abnormal conditions (burnt smell, etc), turn off the power supply and unplug, and please consult authorized dealer.
DEFINITION
The instructions to be followed are classifi ed by the following symbols:
This symbol denotes an action that is PROHIBITED.
These symbols denote actions that are COMPULSORY.
To prevent personal injury, injury to others, or property damage, please observe the following. Incorrect operation due to failure to follow instructions may cause harm or damage, the seriousness of which is classifi ed as below:
Warning
This sign warns of death or serious injury.
Caution
This sign warns of injury or damage to property.
Indoor Unit
• Do not install, remove and reinstall the unit by yourself; improper installation will cause leakage, electric shock or fi re. Please consult authorized dealer or specialist for the installation work.
• Do not insert your fi ngers or other objects into the unit, rotating parts may cause injury.
• Do not attempt to repair the unit by yourself.
Indoor Unit
• Do not install the unit in a potentially explosive atmosphere.
• Do not wash the unit with water, benzene, thinner or scouring powder.
• Do not use for other purposes such as preservation of food.
• Do not use any combustible equipment in front of the airfl ow outlet.
• Do not expose directly to cold air for a long period.
• Ensure that the drainage pipe is connected properly. Otherwise, leakage may occur.
• Aerate the room regularly.
Outdoor Unit
• Do not insert your fi ngers or other objects into the unit, rotating parts may cause injury.
3
ENGLISH
REGULATORY INFORMATION REGULATORY INFORMATION
Thank you for purchasing
Panasonic Air Conditioner
OPERATION CONDITION
OPERATION CONDITION
Use this air conditioner under the following temperature range
Temperature (°C)
Indoor Outdoor
*DBT *WBT *DBT *WBT
COOLING
Maximum 32 23 43 26
Minimum 16 11 16 11
* DBT: Dry bulb temperature * WBT: Wet bulb temperature
TABLE OF CONTENTS
TABLE OF CONTENTS
NOTE :
NOTE :
The illustrations in this manual are for explanation purposes only and may differ from the actual unit. It is subjected to change without notice for future improvement.
SAFETY PRECAUTIONS
2
REGULATORY INFORMATION
3
PRODUCT OVERVIEW & OPERATIONS
4~5
CARE & CLEANING
6
TROUBLESHOOTING
7
QUICK GUIDE
BACK COVER
Replacement or installation of power plugs shall be performed by authorized/ qualifi ed personnel only. The wires in this mains lead are coloured in accordance with the following code:
Terminals
red
wires
live
neutral
earth
colours (GB Standard)
blue
green-yellow
brown
black
green/yellow
Wiring colour may vary depending on a country wiring code’s standard.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
• Do not switch ON the unit when waxing the fl oor. After waxing, aerate the room properly before operating the unit.
• Do not install the unit in oily and smoky areas.
Information for Users on Collection and Disposal of Old Equipment and used Batteries
[Information on Disposal in other Countries outside the European Union]
These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal.
Note for the battery symbol (bottom two symbol examples):
This symbol might be used in combination with a chemical symbol. In this case it complies with the requirement set by the Directive for the chemical involved.
Pb
4
PRODUCT OVERVIEW & OPERATIONS PRODUCT OVERVIEW & OPERATIONS
TO TURN ON OR OFF THE UNIT
• Please be aware of the OFF indication on the remote control display to prevent the unit from starting/stopping improperly.
TO SET TEMPERATURE
• For cool and dry modes, the range of temperature for selection is 16°C ~ 30°C.
• Operating the unit within the recommended temperature could induce energy saving. COOL mode : 26°C ~ 28°C. DRY mode : 1°C ~ 2°C lower than room temperature.
TO SELECT OPERATION MODE
AUTO mode - For your convenience
• Unit selects the operation mode according to the room temperature.
• Once auto mode is selected, the unit will operate at the standard setting temperature.
• To change the standard setting temperature, press
for “HI” or
for “LO”.
Room
temperature
Operation
mode
Standard setting
temperature
HI
(+2°C)
LO
(-2°C)
23°C & above Cool 25°C 27°C 23°C
Below 23°C Dry 22°C 24°C 20°C
COOL mode - To enjoy cool air DRY mode - To dehumidify the environment
• Unit operates at low fan speed to give a gentle cooling operation.
Front panel
Receiver
Auto OFF/ON button
• Used when remote control is misplaced or malfunction.
Action Mode
Press once. Auto Press and hold until 1 beep
is heard, then release.
Cooling
Press the button to turn off.
e-ion AIR PURIFYING SYSTEM
Do not touch during operation
e-ion fi lters e-ion charging wire
Active e-ion Generator
Airfl ow direction louver
• Do not adjust by hand.
Remote control display
Maximum distances: 8m
INDICATOR
(Red/Orange/Blue) (Green)
(Orange) (Orange) (Orange) (Blue)
5
ENGLISH
TO SET THE TIMER
TO SET THE TIMER
• To turn ON or OFF the unit at a preset time.
Select ON or
OFF timer.
Set the time. Confi rm.
• To cancel ON or OFF timer, press
or then
press .
• When ON Timer is set, the unit may start earlier (up to 15 minutes) before the actual set time in order to achieve the desired temperature on time.
• Timer operation is based on the clock set in the remote control and repeats daily once set. For clock setting, please refer to Remote Control Preparation at back cover.
• If timer is cancelled manually or due to power failure, you can restore the previous setting (once power is resumed) by pressing .
TO SELECT FAN SPEED (3 OPTIONS)
• For AUTO, the indoor fan speed is automatically adjusted according to the operation mode.
TO ADJUST AIRFLOW DIRECTION (5 OPTIONS)
• Keeps the room ventilated.
• If AUTO is set, the louvers swing left/right and up/down automatically.
TO ENJOY CLEAN & FRESH AIR
• Generates negative ions to produce fresh air effect and attract dust which will then be captured at the positively charged e-ion fi lters.
TO MONITOR AIR QUALITY
Indicator Air Quality
Blue Clean
Orange Moderate
Red Dirty
• Detects air quality; e-ion
operation activates when air quality is at dirty level.
• Regardless of air quality, to maintain air freshness e-ion activates automatically (PATROL SENSOR indicator turn red) when:
- 2 minutes after the unit is on, or
- exceeds 4 hours at clean level.
• Fan speed is adjusted automatically.
TO ENJOY QUIET ENVIRONMENT
• This operation reduces airfl ow noise.
TO ACHIEVE TEMPERATURE QUICKLY
• This operation will stop automatically after 15 minutes.
, , and can be activated in all modes and can be cancelled by pressing the respective button again.
and or and can not be selected at the same time.
and can be activated even when the unit is turned off. In this condition, fan speed and air swing can not be adjusted.
OPTIONAL SETTINGS
OPTIONAL SETTINGS
Patrol starts automatically with the unit switched on with
.
Press and hold for 5 seconds, then release to disable or restore this setting.
Press and hold for 5 seconds to dim or restore the unit’s indicator brightness.
Press and hold for approximately 10 seconds to show temperature setting in °C or °F.
Press and hold for approximately 5 seconds to show 12-hour (am/pm) or 24-hour time indication.
Press to restore the remote control’s default setting.
Not used in normal operations.
Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mode.
6
CARE & CLEANING CARE & CLEANING
WASHING INSTRUCTIONS
WASHING INSTRUCTIONS
• Do not use benzene, thinner or scouring powder.
• Use only soap (
pH7) or neutral household detergent.
• Do not use water hotter than 40°C.
HINT
HINT
• To ensure optimal performance of the unit, cleaning maintenance have to be carried out at regular intervals. Please consult authorized dealer.
FOR SEASONAL INSPECTION AFTER EXTENDED
FOR SEASONAL INSPECTION AFTER EXTENDED
NON-USE
NON-USE
• Checking of remote control batteries.
• No obstruction at air inlet and air outlet vents.
• After 15 minutes of operation, it is normal to have the following temperature difference between air inlet and air outlet vents: Cooling: 8°C
NON SERVICEABLE CRITERIAS
NON SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY AND UNPLUG then please consult authorized dealer under the following conditions:
• Abnormal noise during operation.
• Water/foreign particles have entered the remote control.
• Water leaks from Indoor unit.
• Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.
• Switches or buttons are not functioning properly.
• Timer indicator blinks.
FOR EXTENDED NON-USE
FOR EXTENDED NON-USE
• Activate e-ion operation for 2~3 hours as an alternative to remove moisture left in the internal parts thoroughly.
• Turn off the power supply and unplug.
• Remove the remote control batteries.
CAUTION
Switch off the power supply and unplug before cleaning.
Do not touch the aluminium fi n, sharp parts may cause injury.
Remove
Remove
ALUMINIUM FIN
ALUMINIUM FIN
• Clean the fi lters regularly.
• Wash/rinse the fi lters gently with water to avoid damage to the fi lter surface.
• Dry the fi lters thoroughly under the shade, away from fi re or direct sunlight.
• Replace any damage fi lter.
e-ion FILTERS
e-ion FILTERS
Clean with dry cotton bud.
• Active e-ion generator cleaning is recommended every 6 months.
ACTIVE e-ion GENERATOR
ACTIVE e-ion GENERATOR
FRONT PANEL
FRONT PANEL
Remove Front Panel
• Raise and pull to remove the front panel.
• Wash gently and dry.
Close Front Panel
• Press down both ends of the front panel to close it securely.
Wipe the unit gently with a soft, dry cloth.
INDOOR UNIT
INDOOR UNIT
e-ion
e-ion
CHARGING WIRE
CHARGING WIRE
Loading...
+ 14 hidden pages