Panasonic Cs-c12bkp Owner's Manual

®
Before using your air-conditioner, please read this operating instructions carefully and keep it for future reference.
Room Air Conditioner
OPERATING INSTRUCTIONS
Before using your air-conditioner, please read this operating instructions
carefully and keep it for future reference.
C
OOLING MODEL
CS-C9BKP CU-C9BKP6
CS-C12BKP CU-C12BKP6
Indoor Outdoor
ENGLISH ....................... P. 1 – P. 11
ESPAÑOL ...................... P. 12 – P. 22
For assistance, please call; 1-800-211-PANA (7262) or send e-mail to: consumerproducts@panasonic.com or refer to
www.panasonic.com
F563366
Thank you for purchasing our Panasonic Room Air Conditioner.
CONTENTS
:Features ..................................................... 1
:Safety Precautions .................................... 2
Installation Precautions
Operation Precautions
:Name of Each Part ................................ 3~4
Indoor Unit
Outdoor Unit
Accessories
Remote Control
:Preparation Before Operation .................. 5
Indoor Unit
Remote Control
:How to Operate ...................................... 5~6
:Setting the Timer ....................................... 7
:Convenience Operation ............................ 7
Sleep Mode Operation
Economy Mode Operation
Powerful Mode Operation
:Care and Maintenance .............................. 8
Cleaning the Indoor Unit and Remote Control
Cleaning the Air Filter
Cleaning the Front Panel
Air Purifying Filters
Pre-season Inspection
When the Air Conditioner is Not Used for an
Extended Period of Time
Recommended Inspection
:Helpful Information ................................... 9
:Energy Saving and Operation Hints ........ 9
:Troubleshooting ...................................... 10
Normal Operation
Abnormal Operation
Call the Dealer Immediately
:
Product Specification and Reference
Note:
Before using your air conditioner, please read this operating instructions carefully and keep it for future reference.
...... 11

FEATURES

Self-illuminating Button
For your convenience to operate in the dark.
(Refer page 4)
Automatic Operation
Sense indoor temperature to select the optimum mode.
(Refer page 5)
Sleep Mode
Prevent the room from getting too hot or too cold while you are sleeping.
(Refer page 7)
Economy Mode
To reduce electrical power consumption.
(Refer page 7)
Powerful Mode
Reaches the desired room temperature quickly.
(Refer page 7)
Removable Front Panel
For quick and easy cleaning. (washable)
(Refer page 8)
Catechin Air Purifying Filter
Filter that can trap dust, tobacco smoke and tiny particles in the room. It can also prevent growth of bacteria and viruses trapped in this filter.
(Refer page 8)
Solar Refreshing Deodorizing Filter
Used to remove unpleasant odour and deodorize the air in the room.
(Refer page 8)
Auto Restart Control
Restart the unit automatically after power failure.
(Refer page 9)
Blue Coated Condenser At Outdoor Unit
This is the most advanced anti-rust coating.
! Warning
1) Operate your air conditioner from a stable 208/230 volts AC supply.
2) Plug into a separate 15 amps grounded outlet only.
3) Use of extension cords. Avoid using extension cords. If there are no alternatives, ensure that the cord is a UL listed 3-wire grounding type, rated 250 volt with a minimum current-carrying rating of 15 amps, number 16 or a heavier wire.
4) Use a 15 amps time delay fuse or a circuit breaker.
5) Do not switch off by unplugging the power plug while it is operating. Turn off the air conditioner by using remote control, before unplugging.
6) Remove power plug or disconnect from the main before servicing this appliance.
7) Do not repair by yourself. In case of malfunction of this appliance, do not repair by yourself. Contact the sales dealer or service dealer for a repair.
8) Turn off the power (Isolation from main power supply). Pull off the power plug from the receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the equipment from the main power supply in case of an emergency.
! Caution
DISCONNECT THE MAIN PLUG FROM THE SUPPLY SOCKET WHEN NOT IN USE, WHERE SUPPLY CONNECTION IS VIA MAIN PLUG.
POWER SUPPLY
Time Delay Fuse: Line Cord Plug:
15 Amps
Rated Volts: Socket Type:
208/230 V
1

SAFETY PRECAUTIONS

Before operating, please read the following “Safety Precautions” carefully.
To prevent personal injury, injury to others and property damage, the following instructions must be followed.
Incorrect operation due to failure to follow instructions will cause harm or damage, the seriousness of which is classified as follow:
! Warning
This sign warns of death or serious injury.
! Caution
This sign warns of damage to property.
The instructions to be followed are classified by the following symbols:
This symbol (with a white background) denotes an
action that is PROHIBITED.

Installation Precautions

! Warning
Do not install, remove and reinstall the unit by yourself.
Improper installation will cause leakage, electric shock or fire. Please engage an authorized dealer or specialist for the installation work.
! Caution
This room air conditioner must be earthed.
Improper grounding could cause electric shock.
Ensure that the drainage piping is connected properly.
Otherwise, water will leak out.
Do not install the unit in a potentially explosive atmosphere.
Gas leak near the unit could cause fire.

Operation Precautions

! Warning
This sign warns of death or serious injury.
Do not share outlet.
Do not insert plug to operate the unit. Do not
pull out plug to stop the unit.
Do not operate with wet hands.
Do not damage or modify the power cord.
Do not insert finger or other objects into the
indoor or outdoor units.
Do not expose directly to cold air for a long period.
Plug in properly.
Use specified power cord.
FF
O
If abnormal condition (burnt smell, etc.) occurs, switch off and unplug the power supply.
! Caution
This sign warns of injury.
Do not pull the cord to disconnect the plug.
Do not wash the unit with water.
Do not use for other purposes such as
preservation.
Do not use any combustible equipment at airflow direction.
Do not sit or place anything on the outdoor unit.
ENGLISH
FF
O
These symbols (with a black background) denote
actions that are COMPULSORY.
Switch off the power supply before cleaning.
Ventilate the room regularly.
Pay attention as to whether the installation
rack is damaged after long period of usage.
OFF
Switch off the power supply if the unit is not used for a long period.
2

NAME OF EACH PART

UT
UT
DR
AN
COOL
UT

Indoor Unit

1
1 Front Panel
2 Air Intake Vent
3 Power Supply Cord
4 Air Outlet Vent
5 Vertical Airflow Direction Louver
6 Horizontal Airflow Direction Louver
(manually adjusted)
7 Indicator Panel
123 654
POWERFULPOWERFULECONOMYECONOMY POWERPOWER
POWERFULPOWERFULECONOMYECONOMY POWERPOWER
2
4576
Indoor Unit

Accessories

(when the front panel is opened)
Remote Control
1
3
2
1 Front Panel
3
AU
T
O
C
O
O
N
O
L
OFF
AU
D
T
R
F
O
YFA
N
AU
POWERFUL
FAN
TEMP
T
M
A
I
S tep
1
ON
OFF
C
H
E
TIM
C
K
R
E
E
R
S
E T
C
C
LO
C
K
+
B A
T T
E R Y
O
O
D
E
OFF/ON
ECONOMY
R
S W
IN
G
S
L
E
E
P
2
FAN SPEED
3
SET
A N
C
E
L
Remote Control Holder
2 Air Filters
3 Air Purifying Filter

Outdoor Unit

Two RO3 (AAA) dry-cell batteries or equivalent
1
6
SLEEPSLEEP
TIMERTIMER
SLEEPSLEEP
TIMERTIMER
2
3
Air Purifying Filter
4
5
1 Auto Operation Button
(when the front panel is opened)
2 Economy Mode Indicator – GREEN
3 Powerful Mode Indicator – ORANGE
4 Power Indicator – GREEN
5 Sleep Mode Indicator – ORANGE
6 Timer Mode Indicator – ORANGE
3
1 Air Intake Vents
2 Ground Terminal
(Inside cover)
3 Piping
4 Connecting Cable
5 Drain Hose
6 Air Outlet Vents
(Catechin Air Purifying Filter)
(Solar Refreshing Deodorizing Filter)